🇵🇱 EXALO DRILLING S.A. PL
Water & wastewater
EXALO DRILLING S.A. is a laboratory accredited by PCA under number AB 1731 (Piła, Poland). Its accreditation scope covers 3 test methods in the following areas: Water & wastewater. Test objects include: Water-based drilling fluid. Most frequently used techniques: Direct measurement method using an automatic viscometer, Gravimetric method, Volumetric method.
At a glance
- Accreditation number: PCA AB 1731
- Methods in scope: 3
- Types of test objects: 1
- Techniques used: 3
- City: Piła, Poland
- Accreditation number
- AB 1731
- Accreditation body
- PCA
- Address
- Pl. Staszica 9, 64-920 Piła, LABORATORIUM PŁYNÓW I CEMENTÓW, ul. Naftowa 3
- City
- Piła, Poland
What this laboratory tests (1)
- Water-based drilling fluid — 3 methods
Analytical techniques used (3)
- Direct measurement method using an automatic viscometer — 1 method
- Gravimetric method — 1 method
- Volumetric method — 1 method
Accreditation scope — test methods (3)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water-based drilling fluid | Density Range (1,00 – 2,35) g/cm3 |
Gravimetric method | PN-EN 10414-1:2012 p.4 | |
| 2 | Water-based drilling fluid | Rheological properties: Shear stress at 600 rpm Shear stress at 300 rpm Plastic viscosity Yield strength Structural strength after 10 s Structural strength after 10 min. |
Direct measurement method using an automatic viscometer | PN-EN 10414-1:2012 Lepkościomierz OFITE Model 900 | |
| 3 | Water-based drilling fluid | Low-temperature low-pressure filtration after 30 min. Range (2,0 – 24,5) ml |
Volumetric method | PN-EN 10414-1:2012 p.7.2 z wyłączeniem punktów 7.2.2.6 oraz 7.2.2.7 | |
Reference standards (3)
PN-EN 10414-1:2012 Lepkościomierz OFITE Model 900
PN-EN 10414-1:2012 p.4
PN-EN 10414-1:2012 p.7.2 z wyłączeniem punktów 7.2.2.6 oraz 7.2.2.7