🇵🇱 ALS POLAND Sp. z o.o. PL
Water & wastewaterEnvironment
ALS POLAND Sp. z o.o. is a laboratory accredited by PCA under number AB 1711 (Skoczów, Poland). Its accreditation scope covers 48 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, wastewater, Water, water intended for human consumption, Soil E, Soil. Most frequently used techniques: Spectrophotometric method, Gas chromatography with mass spectrometry detection (GC-MS), Gravimetric method.
At a glance
- Accreditation number: PCA AB 1711
- Methods in scope: 48
- Types of test objects: 18
- Techniques used: 13
- City: Skoczów, Poland
- Accreditation number
- AB 1711
- Accreditation body
- PCA
- Address
- LABORATORIUM, ul. Stalmacha 23, 43-430 Skoczów
- City
- Skoczów, Poland
What this laboratory tests (18)
- Water, wastewater — 6 methods
- Water, water intended for human consumption — 6 methods
- Soil E — 5 methods
- Soil — 4 methods
- Wastewater — 4 methods
- Water, wastewater, swimming pool water, water intended for human consumption — 4 methods
- Swimming pool water — 3 methods
- Water E, Water intended for human consumption E, Wastewater E — 3 methods
- Water, wastewater, water intended for human consumption — 3 methods
- Water — 2 methods
- Rainwater and snowmelt water — 1 method
- Sewage sludge — 1 method
- Waste code E: 07 03, 07 06, 08 01, 10 12, 12 01, 13 05, 17 05, 19 02, 19 08, 19 09, 19 11, 19 12, 19 13, 20 02 — 1 method
- Waste DAB11): VI Waste from waste treatment; IX Sewage sludge; XI Slags, ashes and furnace dusts; XXVIII Other municipal waste, including mixed waste — 1 method
- Water E, Wastewater E — 1 method
- and 3 more
Analytical techniques used (13)
- Spectrophotometric method — 16 methods
- Gas chromatography with mass spectrometry detection (GC-MS) — 4 methods
- Gravimetric method — 3 methods
- Potentiometric method — 3 methods
- Gas chromatography with flame ionization detection (GC-FID) — 2 methods
- Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) — 2 methods
- Manual method; Automatic method — 2 methods
- Optical method — 2 methods
- Conductometric method — 1 method
- Electrochemical method — 1 method
- Gas chromatography with headspace analysis with mass spectrometry detection (HS-GC-MS) — 1 method
- Headspace gas chromatography with flame ionization detection (HS-GC-FID) — 1 method
- Nephelometric method — 1 method
Accreditation scope — test methods (48)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | Sampling for chemical and physical testing Temperature of wastewater/collected wastewater sample Range (0,0 – 50) °C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 2 | Rainwater and snowmelt water | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 3 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range (0,0 – 36) °C |
PN-ISO 5667-4:2017-10 z wył. p. 15 | PN-EN ISO 5667-6:2016-12 z wył. p. 7.6 | PN-ISO 5667-11:2017-10 z wył. p. 5.2, 6.1.2, 6.2, 6.3 | PN-77 C-04584 | ||
| 4 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of the water sample taken Range (0,0 – 70,0) °C |
PN-ISO 5667-5:2017-10 | PN-77 C-04584 | ||
| 5 | Swimming pool water | Sampling for chemical and physical testing Temperature of the water sample taken Range (0,0 – 70,0) °C |
PN-ISO 5667-5:2017-10 IN-1 Wydanie 2 (01.07.2021) | PN-77 C-04584 | ||
| 6 | Water, swimming pool water, water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 7 | Water, wastewater, swimming pool water, water intended for human consumption | Electrical conductivity+☑ Range (100 – 100 000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 8 | Water, wastewater, swimming pool water, water intended for human consumption | pH +☑ Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 9 | Water, wastewater, swimming pool water, water intended for human consumption | Colour Range (2 – 500) mg/l Pt |
Spectrophotometric method | PN-EN- ISO 7887:2012+Ap1:2015-06 Metoda C | |
| 10 | Water, wastewater, swimming pool water, water intended for human consumption | Turbidity Range (0,10 – 1000) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 11 | Water | Dissolved oxygen concentration ☑ Range (0,5 – 15) mg/l O2 |
Electrochemical method | PN-EN ISO 5814:2013-04 | |
| 12 | Water, wastewater | Total suspended solids (TSS) Range (5,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap.1:2007 | |
| 13 | Water, wastewater | Dry residue Dissolved solids Range (10 – 50000) mg/l |
Gravimetric method | PB-3 wyd. 1 z dnia 01.10.2020 r. | |
| 14 | Water, wastewater | Chemical oxygen demand COD-Cr Range (10,0 – 50000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 15 | Water, wastewater | Biochemical oxygen demand BOD5 Range (1– 6000) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 16 | Water, wastewater | Biochemical oxygen demand BOD5 Range (0,50 – 6,0) mg/l O2 |
Optical method | PN-EN 1899-2:2002 z wyłączeniem punktu 7.2.1, 7.2.2 IN-3 wydanie 2 z dnia 01.07.2024 r. | |
| 17 | Water, wastewater | Total phosphorus concentration Range (0,05 – 200) mg/l |
Spectrophotometric method | ISO 15923-1:2013 | |
| 18 | Water, wastewater, water intended for human consumption | Sulfate concentration Range (5,0 – 5000) mg/l |
Spectrophotometric method | ISO 15923-1:2013 | |
| 19 | Water, wastewater, water intended for human consumption | Chloride concentration Range (2,0 – 5000) mg/l |
Spectrophotometric method | ISO 15923-1:2013 | |
| 20 | Water, wastewater, water intended for human consumption | Total nitrogen concentration (calculated) | PB - 10 wyd.1 z dnia 01.09.2023 | ||
| 21 | Wastewater | Nitrate nitrogen concentration Range (0,50 – 500) mg/l Nitrate concentration Range (2,21 – 2214) mg/l |
Spectrophotometric method | ISO 15923-1:2013 | |
| 22 | Wastewater | Ammonium nitrogen concentration Range (0,50 – 1000) mg/l Ammonium ion concentration Range (0,64 – 1286) mg/l |
Spectrophotometric method | ISO 15923-1:2013 | |
| 23 | Wastewater | Nitrite nitrogen concentration Range (0,10 – 50,0) mg/l Nitrite concentration Range (0,33 – 164) mg/l |
Spectrophotometric method | ISO 15923-1:2013 | |
| 24 | Water, water intended for human consumption | Silica concentration Range (0,08 – 200) mg/l |
Spectrophotometric method | ISO 15923-1:2013 | |
| 25 | Water, water intended for human consumption | Phosphate phosphorus concentration Range (0,01 – 100) mg/l Orthophosphate concentration Range (0,03 – 307) mg/l |
Spectrophotometric method | ISO 15923-1:2013 | |
| 26 | Water, water intended for human consumption | Free chlorine concentration ☑ Range (0,05 – 2,0) mg/l |
Spectrophotometric method | PB-1 wyd. 3 z dnia 01.10.2024 r. | |
| 27 | Water, water intended for human consumption | Nitrate nitrogen concentration Range (0,05 – 200) mg/l Nitrate concentration Range (0,21 – 885) mg/l |
Spectrophotometric method | ISO 15923-1:2013 | |
| 28 | Water, water intended for human consumption | Ammonium nitrogen concentration Range (0,04 – 200) mg/l Ammonium ion concentration Range (0,05 – 257) mg/l |
Spectrophotometric method | ISO 15923-1:2013 | |
| 29 | Water, water intended for human consumption | Nitrite nitrogen concentration Range (0,003 – 5,0) mg/l Nitrite concentration Range (0,010 – 16,4) mg/l Nitrite concentration |
Spectrophotometric method | ISO 15923-1:2013 | |
| 30 | Swimming pool water | Oxidation-reduction potential ☑ (redox) ref. to Ag/AgCl 3,5 mol/l KCl Range (200 – 1000) mV |
Potentiometric method | CSN 75 7367:2011 | |
| 31 | Swimming pool water | Total chlorine concentration ☑ Range (0,05 – 2,0) mg/l Free chlorine concentration Range (0,05 – 2,0) mg/l Combined chlorine (calculated) |
Spectrophotometric method | PB-1 wyd. 3 z dnia 01.10.2024 r. | |
| 32 | Sewage sludge | Sampling for chemical and physical testing | PN-EN ISO 5667-13:2011 | ||
| 33 | Soil | Sampling for chemical and physical testing | PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 | ||
| 34 | Soil | pH - in KCl, pH - in H2O Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 35 | Soil | Dry matter Range (10,0 – 99,5) % Water content Range (0,5 – 90,0) % |
Gravimetric method | PN-ISO 11465:1999 | |
| 36 | Soil | Available phosphorus content as P2O5 Range (1,0 – 50) mg/100 g |
Spectrophotometric method | PB-11 wyd. 1 z dnia 16.10.2023 | |
| 37 | Waste DAB11): VI Waste from waste treatment; IX Sewage sludge; XI Slags, ashes and furnace dusts; XXVIII Other municipal waste, including mixed waste | Sampling for chemical and physical testing | PB-4 wyd.1 z dnia 05.07.2021 | ||
| 38 | Water E, Water intended for human consumption E, Wastewater E, Swimming pool water E | Concentration of volatile organic compounds | Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) | Normy | |
| 39 | Water E, Water intended for human consumption E, Wastewater E | Hydrocarbon concentration (C6-C12) / gasoline fraction components | Headspace gas chromatography with flame ionization detection (HS-GC-FID) | PB-7 | |
| 40 | Water E, Water intended for human consumption E, Wastewater E | Concentration of polycyclic aromatic hydrocarbons (PAH) | Gas chromatography with mass spectrometry detection (GC-MS) | Procedury badawcze | |
| 41 | Water E, Water intended for human consumption E, Wastewater E | Polychlorinated biphenyls (PCB) concentration Sum of PCB (calculated) |
Gas chromatography with mass spectrometry detection (GC-MS) | Procedury badawcze | |
| 42 | Soil E | Volatile aromatic hydrocarbon content | Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) | Normy | |
| 43 | Soil E | Polycyclic aromatic hydrocarbons (PAH) content | Gas chromatography with mass spectrometry detection (GC-MS) | Procedury badawcze | |
| 44 | Soil E | Polychlorinated biphenyls (PCB) content Sum of PCB (calculated) |
Gas chromatography with mass spectrometry detection (GC-MS) | Procedury badawcze | |
| 45 | Soil E | Volatile halogenated hydrocarbon content | Gas chromatography with headspace analysis with mass spectrometry detection (HS-GC-MS) | Normy | |
| 46 | Soil E | Content of petroleum hydrocarbons | Gas chromatography with flame ionization detection (GC-FID) | PB-2 | |
| 47 | Water E, Wastewater E | Concentration of petroleum hydrocarbons | Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2 | |
| 48 | Waste code E: 07 03, 07 06, 08 01, 10 12, 12 01, 13 05, 17 05, 19 02, 19 08, 19 09, 19 11, 19 12, 19 13, 20 02 | Sampling for chemical and physical testing | PB-4 | ||
Reference standards (37)
CSN 75 7367:2011
ISO 15923-1:2013
Normy
PB - 10 wyd.1 z dnia 01.09.2023
PB-1 wyd. 3 z dnia 01.10.2024 r.
PB-11 wyd. 1 z dnia 16.10.2023
PB-2
PB-3 wyd. 1 z dnia 01.10.2020 r.
PB-4
PB-4 wyd.1 z dnia 05.07.2021
PB-7
PN-77 C-04584
PN-77/C-04584
PN-EN 1899-2:2002 z wyłączeniem punktu 7.2.1, 7.2.2 IN-3 wydanie 2 z dnia 01.07.2024 r.
PN-EN 27888:1999
PN-EN 872:2007+Ap.1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-6:2016-12 z wył. p. 7.6
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7027-1:2016-09
PN-EN ISO 9377-2
PN-EN- ISO 7887:2012+Ap1:2015-06 Metoda C
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 11465:1999
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wył. p. 5.2, 6.1.2, 6.2, 6.3
PN-ISO 5667-4:2017-10 z wył. p. 15
PN-ISO 5667-5:2017-10
PN-ISO 5667-5:2017-10 IN-1 Wydanie 2 (01.07.2021)
PN-R-04031:1997
Procedury badawcze