🇵🇱 ALS POLAND Sp. z o.o. PL

PCA AB 1711 • Skoczów, Poland • 48 methods

Water & wastewaterEnvironment

ALS POLAND Sp. z o.o. is a laboratory accredited by PCA under number AB 1711 (Skoczów, Poland). Its accreditation scope covers 48 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, wastewater, Water, water intended for human consumption, Soil E, Soil. Most frequently used techniques: Spectrophotometric method, Gas chromatography with mass spectrometry detection (GC-MS), Gravimetric method.

At a glance

  • Accreditation number: PCA AB 1711
  • Methods in scope: 48
  • Types of test objects: 18
  • Techniques used: 13
  • City: Skoczów, Poland
Accreditation number
AB 1711
Accreditation body
PCA
Address
LABORATORIUM, ul. Stalmacha 23, 43-430 Skoczów
City
Skoczów, Poland

What this laboratory tests (18)

Analytical techniques used (13)

Accreditation scope — test methods (48)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Wastewater Sampling for chemical and physical testing
Temperature of wastewater/collected wastewater sample Range (0,0 – 50) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
2 Rainwater and snowmelt water Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
3 Water Sampling for chemical and physical testing Temperature of the water sample taken
Range (0,0 – 36) °C
PN-ISO 5667-4:2017-10 z wył. p. 15 | PN-EN ISO 5667-6:2016-12 z wył. p. 7.6 | PN-ISO 5667-11:2017-10 z wył. p. 5.2, 6.1.2, 6.2, 6.3 | PN-77 C-04584
4 Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken
Range (0,0 – 70,0) °C
PN-ISO 5667-5:2017-10 | PN-77 C-04584
5 Swimming pool water Sampling for chemical and physical testing Temperature of the water sample taken
Range (0,0 – 70,0) °C
PN-ISO 5667-5:2017-10 IN-1 Wydanie 2 (01.07.2021) | PN-77 C-04584
6 Water, swimming pool water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
7 Water, wastewater, swimming pool water, water intended for human consumption Electrical conductivity+☑
Range (100 – 100 000) μS/cm
Conductometric method PN-EN 27888:1999
8 Water, wastewater, swimming pool water, water intended for human consumption pH +☑
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
9 Water, wastewater, swimming pool water, water intended for human consumption Colour
Range (2 – 500) mg/l Pt
Spectrophotometric method PN-EN- ISO 7887:2012+Ap1:2015-06 Metoda C
10 Water, wastewater, swimming pool water, water intended for human consumption Turbidity
Range (0,10 – 1000) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
11 Water Dissolved oxygen concentration ☑
Range (0,5 – 15) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
12 Water, wastewater Total suspended solids (TSS)
Range (5,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap.1:2007
13 Water, wastewater Dry residue Dissolved solids
Range (10 – 50000) mg/l
Gravimetric method PB-3 wyd. 1 z dnia 01.10.2020 r.
14 Water, wastewater Chemical oxygen demand
COD-Cr Range (10,0 – 50000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
15 Water, wastewater Biochemical oxygen demand
BOD5 Range (1– 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
16 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,50 – 6,0) mg/l O2
Optical method PN-EN 1899-2:2002 z wyłączeniem punktu 7.2.1, 7.2.2 IN-3 wydanie 2 z dnia 01.07.2024 r.
17 Water, wastewater Total phosphorus concentration
Range (0,05 – 200) mg/l
Spectrophotometric method ISO 15923-1:2013
18 Water, wastewater, water intended for human consumption Sulfate concentration
Range (5,0 – 5000) mg/l
Spectrophotometric method ISO 15923-1:2013
19 Water, wastewater, water intended for human consumption Chloride concentration
Range (2,0 – 5000) mg/l
Spectrophotometric method ISO 15923-1:2013
20 Water, wastewater, water intended for human consumption Total nitrogen concentration (calculated) PB - 10 wyd.1 z dnia 01.09.2023
21 Wastewater Nitrate nitrogen concentration
Range (0,50 – 500) mg/l Nitrate concentration Range (2,21 – 2214) mg/l
Spectrophotometric method ISO 15923-1:2013
22 Wastewater Ammonium nitrogen concentration
Range (0,50 – 1000) mg/l Ammonium ion concentration Range (0,64 – 1286) mg/l
Spectrophotometric method ISO 15923-1:2013
23 Wastewater Nitrite nitrogen concentration
Range (0,10 – 50,0) mg/l Nitrite concentration Range (0,33 – 164) mg/l
Spectrophotometric method ISO 15923-1:2013
24 Water, water intended for human consumption Silica concentration
Range (0,08 – 200) mg/l
Spectrophotometric method ISO 15923-1:2013
25 Water, water intended for human consumption Phosphate phosphorus concentration
Range (0,01 – 100) mg/l Orthophosphate concentration Range (0,03 – 307) mg/l
Spectrophotometric method ISO 15923-1:2013
26 Water, water intended for human consumption Free chlorine concentration ☑
Range (0,05 – 2,0) mg/l
Spectrophotometric method PB-1 wyd. 3 z dnia 01.10.2024 r.
27 Water, water intended for human consumption Nitrate nitrogen concentration
Range (0,05 – 200) mg/l Nitrate concentration Range (0,21 – 885) mg/l
Spectrophotometric method ISO 15923-1:2013
28 Water, water intended for human consumption Ammonium nitrogen concentration
Range (0,04 – 200) mg/l Ammonium ion concentration Range (0,05 – 257) mg/l
Spectrophotometric method ISO 15923-1:2013
29 Water, water intended for human consumption Nitrite nitrogen concentration
Range (0,003 – 5,0) mg/l Nitrite concentration Range (0,010 – 16,4) mg/l Nitrite concentration
Spectrophotometric method ISO 15923-1:2013
30 Swimming pool water Oxidation-reduction potential ☑ (redox) ref. to Ag/AgCl 3,5 mol/l KCl
Range (200 – 1000) mV
Potentiometric method CSN 75 7367:2011
31 Swimming pool water Total chlorine concentration ☑
Range (0,05 – 2,0) mg/l Free chlorine concentration Range (0,05 – 2,0) mg/l Combined chlorine (calculated)
Spectrophotometric method PB-1 wyd. 3 z dnia 01.10.2024 r.
32 Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011
33 Soil Sampling for chemical and physical testing PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009
34 Soil pH - in KCl, pH - in H2O
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10390:2022-09
35 Soil Dry matter
Range (10,0 – 99,5) % Water content Range (0,5 – 90,0) %
Gravimetric method PN-ISO 11465:1999
36 Soil Available phosphorus content as P2O5
Range (1,0 – 50) mg/100 g
Spectrophotometric method PB-11 wyd. 1 z dnia 16.10.2023
37 Waste DAB11): VI Waste from waste treatment; IX Sewage sludge; XI Slags, ashes and furnace dusts; XXVIII Other municipal waste, including mixed waste Sampling for chemical and physical testing PB-4 wyd.1 z dnia 05.07.2021
38 Water E, Water intended for human consumption E, Wastewater E, Swimming pool water E Concentration of volatile organic compounds Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Normy
39 Water E, Water intended for human consumption E, Wastewater E Hydrocarbon concentration (C6-C12) / gasoline fraction components Headspace gas chromatography with flame ionization detection (HS-GC-FID) PB-7
40 Water E, Water intended for human consumption E, Wastewater E Concentration of polycyclic aromatic hydrocarbons (PAH) Gas chromatography with mass spectrometry detection (GC-MS) Procedury badawcze
41 Water E, Water intended for human consumption E, Wastewater E Polychlorinated biphenyls (PCB) concentration
Sum of PCB (calculated)
Gas chromatography with mass spectrometry detection (GC-MS) Procedury badawcze
42 Soil E Volatile aromatic hydrocarbon content Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Normy
43 Soil E Polycyclic aromatic hydrocarbons (PAH) content Gas chromatography with mass spectrometry detection (GC-MS) Procedury badawcze
44 Soil E Polychlorinated biphenyls (PCB) content
Sum of PCB (calculated)
Gas chromatography with mass spectrometry detection (GC-MS) Procedury badawcze
45 Soil E Volatile halogenated hydrocarbon content Gas chromatography with headspace analysis with mass spectrometry detection (HS-GC-MS) Normy
46 Soil E Content of petroleum hydrocarbons Gas chromatography with flame ionization detection (GC-FID) PB-2
47 Water E, Wastewater E Concentration of petroleum hydrocarbons Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2
48 Waste code E: 07 03, 07 06, 08 01, 10 12, 12 01, 13 05, 17 05, 19 02, 19 08, 19 09, 19 11, 19 12, 19 13, 20 02 Sampling for chemical and physical testing PB-4

Reference standards (37)

CSN 75 7367:2011
ISO 15923-1:2013
Normy
PB - 10 wyd.1 z dnia 01.09.2023
PB-1 wyd. 3 z dnia 01.10.2024 r.
PB-11 wyd. 1 z dnia 16.10.2023
PB-2
PB-3 wyd. 1 z dnia 01.10.2020 r.
PB-4
PB-4 wyd.1 z dnia 05.07.2021
PB-7
PN-77 C-04584
PN-77/C-04584
PN-EN 1899-2:2002 z wyłączeniem punktu 7.2.1, 7.2.2 IN-3 wydanie 2 z dnia 01.07.2024 r.
PN-EN 27888:1999
PN-EN 872:2007+Ap.1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-6:2016-12 z wył. p. 7.6
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7027-1:2016-09
PN-EN ISO 9377-2
PN-EN- ISO 7887:2012+Ap1:2015-06 Metoda C
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 11465:1999
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wył. p. 5.2, 6.1.2, 6.2, 6.3
PN-ISO 5667-4:2017-10 z wył. p. 15
PN-ISO 5667-5:2017-10
PN-ISO 5667-5:2017-10 IN-1 Wydanie 2 (01.07.2021)
PN-R-04031:1997
Procedury badawcze