🇵🇱 STREFA MICHAŁ GRĄCKI PL
EnvironmentElectronics & EMC
STREFA MICHAŁ GRĄCKI is a laboratory accredited by PCA under number AB 1709 (Zajezierze, Poland). Its accreditation scope covers 22 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Workplace environment − electromagnetic field originating from equi…, Workplace environment − electromagnetic field originating from indu…, Workplace environment - electromagnetic field from transmitting dev…, Workplace environment - electromagnetic field from transmitting dev…. Most frequently used techniques: Direct measurement method, Direct measurement method (simplified).
At a glance
- Accreditation number: PCA AB 1709
- Methods in scope: 22
- Types of test objects: 8
- Techniques used: 2
- City: Zajezierze, Poland
- Accreditation number
- AB 1709
- Accreditation body
- PCA
- Address
- Zajezierze 8E, 88-140 Zajezierze
- City
- Zajezierze, Poland
What this laboratory tests (8)
- Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners — 4 methods
- Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device — 4 methods
- Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) — 3 methods
- Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) — 3 methods
- Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems — 3 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) — 2 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) — 2 methods
- Workplace environment - electromagnetic field in the workspace from magnetotherapy devices — 1 method
Analytical techniques used (2)
- Direct measurement method — 14 methods
- Direct measurement method (simplified) — 1 method
Accreditation scope — test methods (22)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Electric field strength: in the frequency range from 80 MHz do 90 GHz Range (0,5 – 300) V/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 2 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: in the frequency range from 80 MHz do 90 GHz (calculated) |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 3 | Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | Electric field strength: in the frequency range from 27 MHz do 4 GHz Range 0,2 V/m – 255 V/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 4 | Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | Magnetic field strength: in the frequency range from 27 MHz do 4 GHz (calculated) |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 5 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic flux density: in the frequency range from 30 Hz do 50 Hz Range 0,5 μT – 1,9 mT |
Direct measurement method (simplified) | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 | |
| 6 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) | Electric field strength: in the frequency range from 420 MHz do 90 GHz Range (0,5 – 300) V/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 7 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) | Magnetic field strength: in the frequency range from 420 MHz do 800 MHz Range (0,01 – 2) A/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 8 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) | Magnetic field strength: in the frequency range from 800 MHz do 90 GHz (calculated) |
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | ||
| 9 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) | Electric field strength: in the frequency range from 85 MHz do 90 GHz Range (0,5 – 300) V/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 10 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) | Magnetic field strength: in the frequency range from 85 MHz do 1 GHz Range (0,01 – 2) A/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 11 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) | Magnetic field strength: in the frequency range from 800 MHz do 90 GHz (calculated) |
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | ||
| 12 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | Magnetic flux density: in the frequency range 0 Hz Range 100 μT − 1000 mT |
Direct measurement method | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 13 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | Electric field strength: in the frequency range from 27 MHz do 3 GHz Range (0,5 − 300) V/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 14 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | Magnetic field strength: in the frequency range from 27 MHz do 1 GHz Range (0,01 – 2) A/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 15 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | Magnetic field strength: in the frequency range from 1 GHz do 3 GHz (calculated) |
PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | ||
| 16 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | Electric field strength: in the frequency range from 27 MHz do 3 GHz Range (0,5 − 300) V/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 17 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | Magnetic field strength: in the frequency range from 27 MHz do 1 GHz Range (0,01 – 2) A/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 18 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | Magnetic field strength: in the frequency range from 1 GHz do 3 GHz (calculated) |
PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | ||
| 19 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | Magnetic flux density: in the frequency range 0 Hz Range 100 μT − 1000 mT |
Direct measurement method | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 20 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | Electric field strength: in the frequency range from 27 MHz do 3 GHz Range (0,5 − 300) V/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 21 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | Magnetic field strength: in the frequency range from 27 MHz do 1 GHz Range (0,01 – 2) A/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 22 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | Magnetic field strength: in the frequency range from 1 GHz do 3 GHz (calculated) |
PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | ||
Reference standards (7)
PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r.
PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
PN-T-06580-3:2002
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)