🇵🇱 STREFA MICHAŁ GRĄCKI PL

PCA AB 1709 • Zajezierze, Poland • 22 methods

EnvironmentElectronics & EMC

STREFA MICHAŁ GRĄCKI is a laboratory accredited by PCA under number AB 1709 (Zajezierze, Poland). Its accreditation scope covers 22 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Workplace environment − electromagnetic field originating from equi…, Workplace environment − electromagnetic field originating from indu…, Workplace environment - electromagnetic field from transmitting dev…, Workplace environment - electromagnetic field from transmitting dev…. Most frequently used techniques: Direct measurement method, Direct measurement method (simplified).

At a glance

  • Accreditation number: PCA AB 1709
  • Methods in scope: 22
  • Types of test objects: 8
  • Techniques used: 2
  • City: Zajezierze, Poland
Accreditation number
AB 1709
Accreditation body
PCA
Address
Zajezierze 8E, 88-140 Zajezierze
City
Zajezierze, Poland

What this laboratory tests (8)

Analytical techniques used (2)

Accreditation scope — test methods (22)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
in the frequency range from 80 MHz do 90 GHz Range (0,5 – 300) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
2 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 80 MHz do 90 GHz (calculated)
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
3 Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Electric field strength:
in the frequency range from 27 MHz do 4 GHz Range 0,2 V/m – 255 V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
4 Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Magnetic field strength:
in the frequency range from 27 MHz do 4 GHz (calculated)
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
5 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density:
in the frequency range from 30 Hz do 50 Hz Range 0,5 μT – 1,9 mT
Direct measurement method (simplified) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
6 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) Electric field strength:
in the frequency range from 420 MHz do 90 GHz Range (0,5 – 300) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
7 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) Magnetic field strength:
in the frequency range from 420 MHz do 800 MHz Range (0,01 – 2) A/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
8 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) Magnetic field strength:
in the frequency range from 800 MHz do 90 GHz (calculated)
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
9 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) Electric field strength:
in the frequency range from 85 MHz do 90 GHz Range (0,5 – 300) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
10 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 85 MHz do 1 GHz Range (0,01 – 2) A/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
11 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 800 MHz do 90 GHz (calculated)
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
12 Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device Magnetic flux density:
in the frequency range 0 Hz Range 100 μT − 1000 mT
Direct measurement method PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
13 Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device Electric field strength:
in the frequency range from 27 MHz do 3 GHz Range (0,5 − 300) V/m
Direct measurement method PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
14 Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device Magnetic field strength:
in the frequency range from 27 MHz do 1 GHz Range (0,01 – 2) A/m
Direct measurement method PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
15 Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device Magnetic field strength:
in the frequency range from 1 GHz do 3 GHz (calculated)
PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
16 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Electric field strength:
in the frequency range from 27 MHz do 3 GHz Range (0,5 − 300) V/m
Direct measurement method PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
17 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 27 MHz do 1 GHz Range (0,01 – 2) A/m
Direct measurement method PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
18 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 1 GHz do 3 GHz (calculated)
PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
19 Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners Magnetic flux density:
in the frequency range 0 Hz Range 100 μT − 1000 mT
Direct measurement method PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
20 Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners Electric field strength:
in the frequency range from 27 MHz do 3 GHz Range (0,5 − 300) V/m
Direct measurement method PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
21 Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners Magnetic field strength:
in the frequency range from 27 MHz do 1 GHz Range (0,01 – 2) A/m
Direct measurement method PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
22 Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners Magnetic field strength:
in the frequency range from 1 GHz do 3 GHz (calculated)
PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.

Reference standards (7)

PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r.
PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
PN-T-06580-3:2002
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)