🇵🇱 NAŁĘCZÓW ZDRÓJ Sp. z o.o. PL

PCA AB 1665 • Nałęczów, Poland • 13 methods

Water & wastewaterMicrobiology

NAŁĘCZÓW ZDRÓJ Sp. z o.o. is a laboratory accredited by PCA under number AB 1665 (Nałęczów, Poland). Its accreditation scope covers 13 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Natural mineral water, spring…, Water intended for human consumption;, Natural mineral water, sprin…. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Plate method (pour plate).

At a glance

  • Accreditation number: PCA AB 1665
  • Methods in scope: 13
  • Types of test objects: 2
  • Techniques used: 4
  • City: Nałęczów, Poland
Accreditation number
AB 1665
Accreditation body
PCA
Address
UZDROWISKOWE LABORATORIUM ANALITYCZNE, Drzewce 35, 24-150 Nałęczów
City
Nałęczów, Poland

What this laboratory tests (2)

Analytical techniques used (4)

Laboratory locations

Accreditation scope — test methods (13)

No. Test object Methodology / Parameters Technique Reference document
Spa Analytical Laboratory; Drzewce 35; 24-150 Nałęczów
1 Water intended for human consumption, Natural mineral water, spring water and table water Sampling for microbiological testing PN – EN ISO 19458:2007
2 Water intended for human consumption, Natural mineral water, spring water and table water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
3 Water intended for human consumption, Natural mineral water, spring water and table water Pseudomonas aeruginosa count Membrane filtration method I.LAB.M.11 wyd. 2 z 01.08.2017 r.
4 Water intended for human consumption, Natural mineral water, spring water and table water Total count of microorganisms on nutrient agar at a temperature of 36oC and 22oC Plate method (pour plate) PN-EN ISO 6222:2004
5 Water intended for human consumption, Natural mineral water, spring water and table water Escherichia coli and coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
6 Water intended for human consumption, Natural mineral water, spring water and table water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
7 Water intended for human consumption, Natural mineral water, spring water and table water Count of sulphite-reducing Clostridia (including spores) Membrane filtration method PN-EN 26461-2:2001
8 Water intended for human consumption;, Natural mineral water, spring water and table water Sampling for chemical and physical testing PN – ISO 5667-5:2017-10
9 Water intended for human consumption;, Natural mineral water, spring water and table water pH
Range 4,0 – 10,0
Potentiometric method PN – EN ISO 10523:2012
10 Water intended for human consumption;, Natural mineral water, spring water and table water Ammonium ion concentration
Range (0,020-2,5) mg/l
Spectrophotometric method Test Nanocolor nr 91805 wydanie styczeń 2022
11 Water intended for human consumption;, Natural mineral water, spring water and table water Nitrite concentration
Range (0,020-0,60) mg/l
Spectrophotometric method Test Merck nr 1.14776 wydanie grudzień 2024
12 Water intended for human consumption;, Natural mineral water, spring water and table water Nitrate concentration
Range (1,0 - 60) mg/l
Spectrophotometric method Test HACH nr LCK 339 wydanie 2, 06/2025
13 Water intended for human consumption;, Natural mineral water, spring water and table water Manganese concentration
Range (0,010 – 0,70) mg/l
Spectrophotometric method Test HACH nr 8149 Wydanie 11, 02/2024

Reference standards (13)

I.LAB.M.11 wyd. 2 z 01.08.2017 r.
PN – EN ISO 10523:2012
PN – EN ISO 19458:2007
PN – ISO 5667-5:2017-10
PN-EN 26461-2:2001
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 + A1:2017-04
Test HACH nr 8149 Wydanie 11, 02/2024
Test HACH nr LCK 339 wydanie 2, 06/2025
Test Merck nr 1.14776 wydanie grudzień 2024
Test Nanocolor nr 91805 wydanie styczeń 2022