🇵🇱 Laboratorium Pomiarów Środowiska Pracy LUX-MODUS PL

PCA AB 1654 • Bielsko-Biała, Poland • 4 methods

Environment

Laboratorium Pomiarów Środowiska Pracy LUX-MODUS is a laboratory accredited by PCA under number AB 1654 (Bielsko-Biała, Poland). Its accreditation scope covers 4 test methods in the following areas: Environment. Test objects include: Workplace environment − hand-arm vibration, Workplace environment − whole-body vibration.

At a glance

  • Accreditation number: PCA AB 1654
  • Methods in scope: 4
  • Types of test objects: 2
  • City: Bielsko-Biała, Poland
Accreditation number
AB 1654
Accreditation body
PCA
Address
dr Katarzyna Balicka, mgr inż. Piotr Balicki spółka cywilna, ul. Barkowska 9e, 43-300 Bielsko-Biała
City
Bielsko-Biała, Poland

What this laboratory tests (2)

Accreditation scope — test methods (4)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment − hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Range: (0,6 − 1130) m/s2 Direct measurement method PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11
2 Workplace environment − hand-arm vibration Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (a , a , a ) hwx hwy hwz Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (a , a , a ) hwx hwy hwz (calculated)
3 Workplace environment − whole-body vibration Frequency-weighted effective vibration acceleration Range: (0,06 − 35) m/s2 Direct measurement method PN-EN 14253+A1:2011
4 Workplace environment − whole-body vibration Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4a , 1,4a , a ) wx wy wz Exposure lasting 30 minutes and less expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4a , 1,4a , a ) wx wy wz (calculated)

Reference standards (2)

PN-EN 14253+A1:2011
PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11