SONITECH s.c. is a laboratory accredited by PCA under number AB 1638 (Poland). Its accreditation scope covers 10 test methods in the following areas: Environment. Test objects include: General environment – noise from installations, equipment and indus…, Machinery and equipment – noise, General environment – noise from roads, railway lines, tram lines, Rooms in residential, collective residence and public utility build…. Most frequently used techniques: Direct measurement method, Calculation method.

At a glance

  • Accreditation number: PCA AB 1638
  • Methods in scope: 10
  • Types of test objects: 4
  • Techniques used: 2
Accreditation number
AB 1638
Accreditation body
PCA
Address
Krzysztof Jarzyna, Wojciech Węglewski, ul. Sieczna 70/12, 03 – 290 Warszawa
City
Poland

What this laboratory tests (4)

Analytical techniques used (2)

Accreditation scope — test methods (10)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 – 120) dB
Direct measurement method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN ISO 9613-2:2002
2 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN ISO 9613-2:2002
3 General environment – noise from installations, equipment and industrial plants Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN Calculation method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | PN ISO 9613-2:2002
4 General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level
Range (25 – 120) dB
Direct measurement method Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H
5 General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H
6 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (22 – 100) dB
Direct measurement method PN-87/B-02156
7 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156
8 Machinery and equipment – noise A-frequency-weighted sound pressure level PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09
9 Machinery and equipment – noise Sound pressure level
of a single event weighted with the characteristic frequency weighting A Range (25 – 120) dB
Direct measurement method PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09
10 Machinery and equipment – noise Sound power level, Sound energy level (calculated) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09

Reference standards (6)

PN ISO 9613-2:2002
PN-87/B-02156
PN-EN ISO 3746:2011
PN-EN ISO 3746:2011/Ap1:2017-09
Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)