🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 1633 • Konin, Poland • 40 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1633 (Konin, Poland). Its accreditation scope covers 40 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Sewage sludge, Wastewater, Water, wastewater.

At a glance

  • Accreditation number: PCA AB 1633
  • Methods in scope: 40
  • Types of test objects: 7
  • City: Konin, Poland
Accreditation number
AB 1633
Accreditation body
PCA
Address
ul. Poznańska 49, 62-510 Konin, LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Nadrzeczna 70
City
Konin, Poland

What this laboratory tests (7)

Accreditation scope — test methods (40)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water Sampling for chemical and physical testing Temperature of water/of the water sample taken Range: (1,0 – 50) °C PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2 | PN-77/C-04584
2 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
3 Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
4 Water intended for human consumption Clostridium perfringens count Membrane filtration method PN-EN ISO 14189:2016-10
5 Water intended for human consumption Free chlorine concentration Range: (0,1 – 4,5) mg/l Colorimetric method PB/LBS/L-14 wyd. 02 z dn. 24.05.2021 r.
6 Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3
7 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04
8 Water, water intended for human consumption Escherichia coli count Membrane filtration method
9 Water, water intended for human consumption Most probable number of coliform bacteria MPN method (Colilert 18 Test) PN-EN ISO 9308-2:2014-06
10 Water, water intended for human consumption Most probable number of Escherichia coli MPN method (Colilert 18 Test)
11 Water, water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
12 Water, water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
13 Water, water intended for human consumption Total viable count at 36°C Plate method (pour plate)
14 Water, water intended for human consumption pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012
15 Water, water intended for human consumption Turbidity Range: (0,20 – 10) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
16 Water, water intended for human consumption Electrical conductivity Range: (147 – 3000) µS/cm Conductometric method PN-EN 27888:1999
17 Water, water intended for human consumption Total iron concentration Range: (30 – 10000) µg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
18 Water, water intended for human consumption Manganese concentration Range: (20 – 1000) µg/l Spectrophotometric method PN-92/C-04590/03
19 Water, water intended for human consumption Colour Range: (5,0 – 120) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 + Ap1:2015 Metoda C
20 Water, water intended for human consumption, wastewater Anion concentrations Range: nitrates (0,50 – 200) mg/l nitrites (0,10 – 80) mg/l chlorides (2,0 – 2500) mg/l fluorides (0,10 – 50) mg/l phosphates (0,10 – 250) mg/l sulfates (2,0 – 800) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
21 Water, water intended for human consumption, wastewater Cation concentration Range: sodium (2,0 – 300) mg/l ammonium ion (0,10 – 300) mg/l potassium (0,40 – 50) mg/l calcium (4,0 – 200) mg/l magnesium (2,0 – 200) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 14911:2002
22 Water, water intended for human consumption, wastewater Total organic carbon concentration Range: (1,0 – 300) mg/l High-temperature combustion with IR detection PN-EN 1484:1999
23 Water, water intended for human consumption, wastewater Total calcium and magnesium content (total hardness) (calculated) PB/LBS/18 wyd. 01 z dn. 26.08.2019 r.
24 Water, water intended for human consumption, wastewater Dissolved solids Range: (100 – 10000) mg/l Gravimetric method PN-78/C-04541
25 Water, wastewater Kjeldahl nitrogen concentration Range: (1,0 – 1000) mg/l Titrimetric method PN-EN 25663:2001
26 Water, wastewater Total nitrogen concentration (calculated) PB/LBS/12:2019 wyd.03 z dn. 16.12.2019
27 Water, wastewater Chemical oxygen demand - COD Range: (5,00 – 10000) mg/l O 2 Spectrophotometric method PN-EN ISO 15705:2005
28 Water, wastewater Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
29 Water, wastewater Total phosphorus concentration Range: (0,08 – 80) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
30 Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (1,0 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584
31 Wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012
32 Wastewater Biochemical oxygen demand - BOD 5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
33 Wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
34 Wastewater Petroleum ether extractable substances Range: (2,0 – 400) mg/l Gravimetric method PB/LBS/05 wyd. 04 z dn. 30.07.2018 r.
35 Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011
36 Sewage sludge pH Range: 1,0 – 13,0 Potentiometric method PN-EN 12176:2004
37 Sewage sludge Dry residue Range: (1,0 – 96) % Gravimetric method PN-EN 12880:2004
38 Sewage sludge Water content (calculated)
39 Sewage sludge Loss on ignition of dry matter (organic matter content) Range: (1 – 96) % Gravimetric method PN-EN 12879:2004
40 Sewage sludge Residue on ignition of dry matter (mineral substance content) (calculated)

Reference standards (35)

PB/LBS/05 wyd. 04 z dn. 30.07.2018 r.
PB/LBS/12:2019 wyd.03 z dn. 16.12.2019
PB/LBS/18 wyd. 01 z dn. 26.08.2019 r.
PB/LBS/L-14 wyd. 02 z dn. 24.05.2021 r.
PN-77/C-04584
PN-78/C-04541
PN-92/C-04590/03
PN-EN 12176:2004
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 1484:1999
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 14911:2002
PN-EN ISO 15705:2005
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3
PN-EN ISO 5667-13:2011
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 + Ap1:2015 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12+ A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2
PN-ISO 5667-5:2017-10
PN-ISO 6332:2001+Ap1:2016-06