🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1633 (Konin, Poland). Its accreditation scope covers 40 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Sewage sludge, Wastewater, Water, wastewater.
At a glance
- Accreditation number: PCA AB 1633
- Methods in scope: 40
- Types of test objects: 7
- City: Konin, Poland
- Accreditation number
- AB 1633
- Accreditation body
- PCA
- Address
- ul. Poznańska 49, 62-510 Konin, LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Nadrzeczna 70
- City
- Konin, Poland
What this laboratory tests (7)
- Water, water intended for human consumption — 14 methods
- Sewage sludge — 6 methods
- Wastewater — 5 methods
- Water, wastewater — 5 methods
- Water, water intended for human consumption, wastewater — 5 methods
- Water intended for human consumption — 4 methods
- Water — 1 method
Accreditation scope — test methods (40)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water | Sampling for chemical and physical testing Temperature of water/of the water sample taken Range: (1,0 – 50) °C | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2 | PN-77/C-04584 | ||
| 2 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 3 | Water intended for human consumption | Pseudomonas aeruginosa count Membrane filtration method | PN-EN ISO 16266:2009 | ||
| 4 | Water intended for human consumption | Clostridium perfringens count Membrane filtration method | PN-EN ISO 14189:2016-10 | ||
| 5 | Water intended for human consumption | Free chlorine concentration Range: (0,1 – 4,5) mg/l Colorimetric method | PB/LBS/L-14 wyd. 02 z dn. 24.05.2021 r. | ||
| 6 | Water, water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3 | ||
| 7 | Water, water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12+ A1:2017-04 | ||
| 8 | Water, water intended for human consumption | Escherichia coli count Membrane filtration method | |||
| 9 | Water, water intended for human consumption | Most probable number of coliform bacteria MPN method (Colilert 18 Test) | PN-EN ISO 9308-2:2014-06 | ||
| 10 | Water, water intended for human consumption | Most probable number of Escherichia coli MPN method (Colilert 18 Test) | |||
| 11 | Water, water intended for human consumption | Enterococci count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 12 | Water, water intended for human consumption | Total viable count at 22°C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 13 | Water, water intended for human consumption | Total viable count at 36°C Plate method (pour plate) | |||
| 14 | Water, water intended for human consumption | pH Range: 2,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 15 | Water, water intended for human consumption | Turbidity Range: (0,20 – 10) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 16 | Water, water intended for human consumption | Electrical conductivity Range: (147 – 3000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 17 | Water, water intended for human consumption | Total iron concentration Range: (30 – 10000) µg/l Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | ||
| 18 | Water, water intended for human consumption | Manganese concentration Range: (20 – 1000) µg/l Spectrophotometric method | PN-92/C-04590/03 | ||
| 19 | Water, water intended for human consumption | Colour Range: (5,0 – 120) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 + Ap1:2015 Metoda C | ||
| 20 | Water, water intended for human consumption, wastewater | Anion concentrations Range: nitrates (0,50 – 200) mg/l nitrites (0,10 – 80) mg/l chlorides (2,0 – 2500) mg/l fluorides (0,10 – 50) mg/l phosphates (0,10 – 250) mg/l sulfates (2,0 – 800) mg/l Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | ||
| 21 | Water, water intended for human consumption, wastewater | Cation concentration Range: sodium (2,0 – 300) mg/l ammonium ion (0,10 – 300) mg/l potassium (0,40 – 50) mg/l calcium (4,0 – 200) mg/l magnesium (2,0 – 200) mg/l Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 14911:2002 | ||
| 22 | Water, water intended for human consumption, wastewater | Total organic carbon concentration Range: (1,0 – 300) mg/l High-temperature combustion with IR detection | PN-EN 1484:1999 | ||
| 23 | Water, water intended for human consumption, wastewater | Total calcium and magnesium content (total hardness) (calculated) | PB/LBS/18 wyd. 01 z dn. 26.08.2019 r. | ||
| 24 | Water, water intended for human consumption, wastewater | Dissolved solids Range: (100 – 10000) mg/l Gravimetric method | PN-78/C-04541 | ||
| 25 | Water, wastewater | Kjeldahl nitrogen concentration Range: (1,0 – 1000) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 26 | Water, wastewater | Total nitrogen concentration (calculated) | PB/LBS/12:2019 wyd.03 z dn. 16.12.2019 | ||
| 27 | Water, wastewater | Chemical oxygen demand - COD Range: (5,00 – 10000) mg/l O 2 Spectrophotometric method | PN-EN ISO 15705:2005 | ||
| 28 | Water, wastewater | Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 29 | Water, wastewater | Total phosphorus concentration Range: (0,08 – 80) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 | ||
| 30 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (1,0 – 50) °C | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 31 | Wastewater | pH Range: 2,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 32 | Wastewater | Biochemical oxygen demand - BOD 5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 33 | Wastewater | Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 34 | Wastewater | Petroleum ether extractable substances Range: (2,0 – 400) mg/l Gravimetric method | PB/LBS/05 wyd. 04 z dn. 30.07.2018 r. | ||
| 35 | Sewage sludge | Sampling for chemical and physical testing | PN-EN ISO 5667-13:2011 | ||
| 36 | Sewage sludge | pH Range: 1,0 – 13,0 Potentiometric method | PN-EN 12176:2004 | ||
| 37 | Sewage sludge | Dry residue Range: (1,0 – 96) % Gravimetric method | PN-EN 12880:2004 | ||
| 38 | Sewage sludge | Water content (calculated) | |||
| 39 | Sewage sludge | Loss on ignition of dry matter (organic matter content) Range: (1 – 96) % Gravimetric method | PN-EN 12879:2004 | ||
| 40 | Sewage sludge | Residue on ignition of dry matter (mineral substance content) (calculated) | |||
Reference standards (35)
PB/LBS/05 wyd. 04 z dn. 30.07.2018 r.
PB/LBS/12:2019 wyd.03 z dn. 16.12.2019
PB/LBS/18 wyd. 01 z dn. 26.08.2019 r.
PB/LBS/L-14 wyd. 02 z dn. 24.05.2021 r.
PN-77/C-04584
PN-78/C-04541
PN-92/C-04590/03
PN-EN 12176:2004
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 1484:1999
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 14911:2002
PN-EN ISO 15705:2005
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3
PN-EN ISO 5667-13:2011
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 + Ap1:2015 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12+ A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2
PN-ISO 5667-5:2017-10
PN-ISO 6332:2001+Ap1:2016-06