🇵🇱 ChM sp. z o.o. PL

PCA AB 1629 • Juchnowiec Kościelny, Poland • 8 methods

Materials & polymersWater & wastewaterMicrobiology

ChM sp. z o.o. is a laboratory accredited by PCA under number AB 1629 (Juchnowiec Kościelny, Poland). Its accreditation scope covers 8 test methods in the following areas: Materials & polymers, Water & wastewater, Microbiology. Test objects include: Metals, metal alloys, metal products, Meto, Medical devices (implants and instruments), Water. Most frequently used techniques: Comparative method according to the scale of standards; Intercept m…, Culture method: direct immersion, membrane filtration, Inductively coupled plasma optical emission spectrometry (ICP-OES).

At a glance

  • Accreditation number: PCA AB 1629
  • Methods in scope: 8
  • Types of test objects: 3
  • Techniques used: 8
  • City: Juchnowiec Kościelny, Poland
Accreditation number
AB 1629
Accreditation body
PCA
Address
Lewickie 3B, 16-061 Juchnowiec Kościelny
City
Juchnowiec Kościelny, Poland

What this laboratory tests (3)

Analytical techniques used (8)

Laboratory sections (3)

Laboratory locations

Certificate information

Issue date
20.07.2026
Issue no.
11

Accreditation scope — test methods (8)

No. Test object Methodology / Parameters Technique Reference document
Biomechanical Laboratory; Lewickie 3B, 16-061 Juchnowiec Kościelny
1 Metals, metal alloys, metal products, Meto Mechanical properties:
proof strength, plastic extension Rp distinct yield strength Re tensile strength Rm extensometer elongation Ag, At, Agt, elongation A reduction of area Z force do 100 kN
Method: Tensile test at room temperature PN-EN ISO 6892-1:2020-05 metoda B
2 Metals, metal alloys, metal products, Meto Mechanical properties:
bending strength bending stiffness K structural bending stiffness Ele force do 100 kN
Method: Static 4-point bending test ASTM F382-24 Annex A1
3 Metals, metal alloys, metal products, Meto Grain size
Optical microscopy
Comparative method according to the scale of standards; Intercept method; Planimetric method ASTM E112-25 | PN-EN ISO 643:2025-02
4 Metals, metal alloys, metal products, Meto Mechanical strengths:
maximum load, displacement at maximum load, load at 2% deformation, displacement in the elastic range, bending stiffness
Method: static compressive bending test ASTM F1717-21
Microbiology Laboratory; Lewickie 3B, 16-061 Juchnowiec Kościelny
5 Medical devices (implants and instruments) Microorganism count, Aerobic bacteria count, Fungal count (yeasts and moulds) Membrane filtration method PN-EN ISO 11737-1:2018-03
6 Medical devices (implants and instruments) Sterility Culture method: direct immersion, membrane filtration PN-EN ISO 11737-2:2020-11
Physicochemical Laboratory; Lewickie 3B, 16-061 Juchnowiec Kościelny
7 Water Total organic carbon TOC concentration
Range (0,2 – 10) mg/l
Spectrometry method in the infrared range (IR) PN-EN 1484:1999
8 Water Element concentration
Mo (5,0 - 1000) μg/l Pb (5,0 - 1000) μg/l Co (3,0 - 1000) μg/l Ni (3,0 - 1000) μg/l Cr (3,0 - 1000) μg/l V (3,0 - 1000) μg/l Cu (3,0 - 1000) μg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009

Reference standards (9)

ASTM E112-25
ASTM F1717-21
ASTM F382-24 Annex A1
PN-EN 1484:1999
PN-EN ISO 11737-1:2018-03
PN-EN ISO 11737-2:2020-11
PN-EN ISO 11885:2009
PN-EN ISO 643:2025-02
PN-EN ISO 6892-1:2020-05 metoda B

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201629