🇵🇱 GMINA KIELCE PL

PCA AB 1591 • Kielce, Poland • 8 methods

Water & wastewater

GMINA KIELCE is a laboratory accredited by PCA under number AB 1591 (Kielce, Poland). Its accreditation scope covers 8 test methods in the following areas: Water & wastewater. Test objects include: Bituminous mixtures, Aggregates, Road pavements.

At a glance

  • Accreditation number: PCA AB 1591
  • Methods in scope: 8
  • Types of test objects: 3
  • City: Kielce, Poland
Accreditation number
AB 1591
Accreditation body
PCA
Address
MIEJSKI ZARZĄD DRÓG W KIELCACH, LABORATORIUM, ul. Prendowskiej 7, 25-395 Kielce
City
Kielce, Poland

What this laboratory tests (3)

Accreditation scope — test methods (8)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Aggregates Grain composition Range: (0 – 63) mm PN-EN 933-1:2012
2 Aggregates Water content PN-EN 1097-5:2008
3 Aggregates Sampling PN-EN 932-1:1999 p. 8.8
4 Bituminous mixtures Grading Range: (0 – 31,5) mm PN-EN 12697-2+A1:2019-12 PN-EN 933-1:2012
5 Bituminous mixtures Bulk density Range: (2,100 – 3,000) Mg/m3 Method: B PN-EN 12697-6:2020-07
6 Bituminous mixtures Soluble binder content Range: (2 – 10) % PN-EN 12697-1:2020-08 p. B.1.7
7 Bituminous mixtures Resistance to deformation under load Range: WTS = (0 – 1,5) mm/1000 cycles AIR PRD = (0 – 30) % AIR Method: wheel tracking by method B (in air), small device PN-EN 12697-22:2020-07
8 Road pavements Thickness Range: (0 – 300) mm PN-EN 12697-36:2022-09 p. 6.1

Reference standards (8)

PN-EN 1097-5:2008
PN-EN 12697-1:2020-08 p. B.1.7
PN-EN 12697-2+A1:2019-12 PN-EN 933-1:2012
PN-EN 12697-22:2020-07
PN-EN 12697-36:2022-09 p. 6.1
PN-EN 12697-6:2020-07
PN-EN 932-1:1999 p. 8.8
PN-EN 933-1:2012