🇵🇱 WODOCIĄGI I KANALIZACJA W OPOLU Sp. z o.o. PL
Water & wastewaterMicrobiology
WODOCIĄGI I KANALIZACJA W OPOLU Sp. z o.o. is a laboratory accredited by PCA under number AB 1589 (Opole, Poland). Its accreditation scope covers 33 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water Wastewater, Wastewater, Water intended for human consumption Wastewater.
At a glance
- Accreditation number: PCA AB 1589
- Methods in scope: 33
- Types of test objects: 6
- City: Opole, Poland
- Accreditation number
- AB 1589
- Accreditation body
- PCA
- Address
- DZIAŁ LABORATORIUM, ul. Oleska 64, 45-222 Opole
- City
- Opole, Poland
What this laboratory tests (6)
- Water intended for human consumption — 15 methods
- Water Wastewater — 9 methods
- Wastewater — 5 methods
- Water intended for human consumption Wastewater — 2 methods
- Rainwater and snowmelt water — 1 method
- Wastewater Rainwater and snowmelt water — 1 method
Accreditation scope — test methods (33)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 2 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 3 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method | PN-ISO 5667-10:2021-11 | ||
| 4 | Rainwater and snowmelt water | Sampling for chemical and physical testing Manual method | PN-ISO 5667-10:2021-11 | ||
| 5 | Water Wastewater | pH Range: 4,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 6 | Water Wastewater | Kjeldahl nitrogen concentration Range: (2,0 – 200) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 7 | Water Wastewater | Total suspended solids Range: (4,0 – 2000) mg/l Gravimetric method | PN-EN 872:2007 PN-EN 872:2007/Ap1:2007 | ||
| 8 | Water Wastewater | Chemical oxygen demand - COD-Cr Range: (15,0 – 10000) mg/l O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 9 | Water Wastewater | Nitrite nitrogen concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method Nitrite concentration (calculated) | PN-EN 26777:1999 | ||
| 10 | Water Wastewater | Nitrate nitrogen concentration Range: (0,35 – 12,0) mg/l Spectrophotometric method Nitrate concentration (calculated) | PN-82/C-04576/08 | ||
| 11 | Water Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 12 | Water Wastewater | Total phosphorus concentration Range: (0,1 – 50) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 p.8 PN-EN ISO 6878:2006/Ap1:2010 PN-EN ISO 6878:2006/Ap2:2010 | ||
| 13 | Water Wastewater | Biochemical oxygen demand - BOD 5 Range: (3,0 – 700) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 14 | Wastewater | Ammonium nitrogen concentration Range: (0,5 – 100) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 15 | Wastewater | Petroleum ether extractable substances Range: (5,0 – 1200) mg/l Gravimetric method | PN-86/C-04573-01 | ||
| 16 | Wastewater | Zinc concentration Range: (0,05 – 10) mg/l Flame atomic absorption spectrometry method (FAAS) | PN-ISO 8288:2002 (metoda A) | ||
| 17 | Wastewater | Metal concentrations Range: lead (0,002 – 0,200) mg/l cadmium (0,0001 – 0,0300) mg/l chromium (0,002 – 0,500) mg/l copper (0,002 – 0,200) mg/l nickel (0,005 – 0,400) mg/l Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 15586:2005 | ||
| 18 | Wastewater Rainwater and snowmelt water | Mineral oil index Range: (1,0 – 100) mg/l Gas chromatography with flame ionisation detection (GC-FID) | PN-EN ISO 9377-2:2003 | ||
| 19 | Water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12/A1:2017- 04 | ||
| 20 | Water intended for human consumption | Escherichia coli count Membrane filtration method | |||
| 21 | Water intended for human consumption | Enterococci (faecal streptococci) count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 22 | Water intended for human consumption | Total count of microorganisms at 22C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 23 | Water intended for human consumption | Total count of microorganisms at 36C Plate method (pour plate) | |||
| 24 | Water intended for human consumption | pH Range: 4,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 25 | Water intended for human consumption | Nitrite nitrogen concentration Range: (0,04 – 2,0) mg/l Spectrophotometric method Nitrite concentration (calculated) | PN-EN 26777:1999 | ||
| 26 | Water intended for human consumption | Nitrate nitrogen concentration Range: (0,35 – 12,0) mg/l Spectrophotometric method Nitrate concentration (calculated) | PN-82/C-04576/08 | ||
| 27 | Water intended for human consumption | Manganese concentration Range: (0,10 – 3,0) mg/l Spectrophotometric method | PN-92/C-04590.02 | ||
| 28 | Water intended for human consumption | Turbidity Range: (0,10 – 10,0) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 29 | Water intended for human consumption | Electrical conductivity Range: (100 – 2500) μS/cm Conductometric method | PN-EN 27888:1999 | ||
| 30 | Water intended for human consumption | Total iron concentration Range: (0,04 – 4,0) mg/l Spectrophotometric method | PN-ISO 6332:2001 PN-ISO 6332:2001/Ap1:2016-06 | ||
| 31 | Water intended for human consumption | Total calcium and magnesium content (total hardness) Range: (10 – 500) mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 32 | Water intended for human consumption Wastewater | Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 33 | Water intended for human consumption Wastewater | Sulfate concentration Range: (10 – 500) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
Reference standards (27)
PN-73/C-04576/14
PN-82/C-04576/08
PN-86/C-04573-01
PN-92/C-04590.02
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 PN-EN 872:2007/Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 15586:2005
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p.8 PN-EN ISO 6878:2006/Ap1:2010 PN-EN ISO 6878:2006/Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12/A1:2017- 04
PN-EN ISO 9377-2:2003
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001 PN-ISO 6332:2001/Ap1:2016-06
PN-ISO 8288:2002 (metoda A)
PN-ISO 9280:2002
PN-ISO 9297:1994