🇵🇱 Centralna Stacja Ratownictwa Górniczego S.A PL
Environment
Centralna Stacja Ratownictwa Górniczego S.A is a laboratory accredited by PCA under number AB 1584 (Bytom, Poland). Its accreditation scope covers 5 test methods in the following areas: Environment. Test objects include: General environment: - air samples, - mine air samples, - mine gas…. Most frequently used techniques: Gas chromatography with thermal conductivity detection (GC-TCD), Gas chromatography with flame ionization detection (GC-FID).
At a glance
- Accreditation number: PCA AB 1584
- Methods in scope: 5
- Types of test objects: 1
- Techniques used: 2
- City: Bytom, Poland
- Accreditation number
- AB 1584
- Accreditation body
- PCA
- Address
- Zespół Badawczy Laboratorium Chemicznego, ul. Chorzowska 25, 41 – 902 Bytom
- City
- Bytom, Poland
What this laboratory tests (1)
- General environment: - air samples, - mine air samples, - mine gas samples, - mixtures of technical gases. — 5 methods
Analytical techniques used (2)
- Gas chromatography with thermal conductivity detection (GC-TCD) — 3 methods
- Gas chromatography with flame ionization detection (GC-FID) — 2 methods
Accreditation scope — test methods (5)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | General environment: - air samples, - mine air samples, - mine gas samples, - mixtures of technical gases. | CO, CO2 concentration Carbon monoxide (10 – 5000) ppm Carbon dioxide (0,05 – 0,50) % |
Gas chromatography with flame ionization detection (GC-FID) | Procedura PB:GC Wydanie 5 z dnia 30.08.2024 r. | |
| 2 | General environment: - air samples, - mine air samples, - mine gas samples, - mixtures of technical gases. | CO, CO2 concentration Carbon monoxide (5001 – 50 000) ppm Carbon dioxide (0,50 – 10,00) % |
Gas chromatography with thermal conductivity detection (GC-TCD) | Procedura PB:GC Wydanie 5 z dnia 30.08.2024 r. | |
| 3 | General environment: - air samples, - mine air samples, - mine gas samples, - mixtures of technical gases. | Hydrocarbon concentration Methane (0,05 – 0,50) % Ethane (1 – 5 000) ppm Propane (10,0 – 3000,0) ppm Ethene (ethylene) 50,00 – 5000,00 ppm |
Gas chromatography with flame ionization detection (GC-FID) | Procedura PB:GC Wydanie 5 z dnia 30.08.2024 r. | |
| 4 | General environment: - air samples, - mine air samples, - mine gas samples, - mixtures of technical gases. | Hydrocarbon concentration Methane (0,50 – 75,00) % Ethane (5001 – 6 000) ppm |
Gas chromatography with thermal conductivity detection (GC-TCD) | Procedura PB:GC Wydanie 5 z dnia 30.08.2024 r. | |
| 5 | General environment: - air samples, - mine air samples, - mine gas samples, - mixtures of technical gases. | H2, O2, N2 concentration Hydrogen (10 – 25000) ppm Oxygen (0,05 – 21,00) % Nitrogen (0,05 – 96,00) % |
Gas chromatography with thermal conductivity detection (GC-TCD) | Procedura PB:GC Wydanie 5 z dnia 30.08.2024 r. | |
Reference standards (1)
Procedura PB:GC Wydanie 5 z dnia 30.08.2024 r.