🇵🇱 SOLDI sp. z o.o. PL

PCA AB 1571 • Kraków, Poland • 59 methods

EnvironmentElectronics & EMC

SOLDI sp. z o.o. is a laboratory accredited by PCA under number AB 1571 (Kraków, Poland). Its accreditation scope covers 59 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment - electromagnetic field in the workspace orig…, Workplace environment - electromagnetic field originating from equi…, Workplace environment - electromagnetic field originating from indu…. Most frequently used techniques: Direct measurement method, Gravimetric method, Direct measurement method (simplified).

At a glance

  • Accreditation number: PCA AB 1571
  • Methods in scope: 59
  • Types of test objects: 21
  • Techniques used: 4
  • City: Kraków, Poland
Accreditation number
AB 1571
Accreditation body
PCA
Address
ul. Bieżanowska 22, 30-812 Kraków
City
Kraków, Poland

What this laboratory tests (21)

Analytical techniques used (4)

Laboratory locations

Accreditation scope — test methods (59)

No. Test object Methodology / Parameters Technique Reference document
Laboratorium Badawcze SOLDI
1 Workplace environment - electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters Electric field strength:
in the frequency range from 10 Hz do 500 kHz Range 1 V/m – 49 kV/m in the frequency range from 100 kHz do 3 GHz Range (1,0 – 980) V/m in the frequency range from 80 MHz do 90 GHz Range (1,0 – 350) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 1
2 Workplace environment - electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters Magnetic flux density:
with a frequency of 0 Hz Range 0,3 mT – 1 T in the frequency range from 10 Hz do 500 kHz Range 0,1 µT – 19 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 1
3 Workplace environment - electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters Magnetic field strength:
in the frequency range from 300 kHz do 35 MHz Range (0,010 – 16,0) A/m w zakresie częstotliwości od 20 MHz do 1 GHz Range (0,010 – 10,0) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 1
4 Workplace environment - electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters Magnetic field strength:
w zakresie częstotliwości: od 1 GHz do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 1
5 Workplace environment - electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Electric field strength:
in the frequency range from 10 Hz do 500 kHz Range 1 V/m – 49 kV/m in the frequency range from 100 kHz do 3 GHz Range (1,0 – 980) V/m in the frequency range from 80 MHz do 90 GHz Range (1,0 – 350) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 2
6 Workplace environment - electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic flux density:
with a frequency of 0 Hz Range 0,3 mT – 1 T in the frequency range from 10 Hz do 500 kHz Range 0,1 µT – 19 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 2
7 Workplace environment - electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 300 kHz do 35 MHz Range (0,010 – 16,0) A/m w zakresie częstotliwości od 20 MHz do 1 GHz Range (0,010 – 10,0) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 2
8 Workplace environment - electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
w zakresie częstotliwości: od 1 GHz do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 2
9 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Electric field strength:
in the frequency range from 10 Hz do 500 kHz Range 1 V/m – 49 kV/m in the frequency range from 100 kHz do 3 GHz Range (1,0 – 980) V/m in the frequency range from 80 MHz do 90 GHz Range (1,0 – 350) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 3
10 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Magnetic flux density:
with a frequency of 0 Hz Range 0,3 mT – 1 T in the frequency range from 10 Hz do 500 kHz Range 0,1 µT – 19 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 3
11 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Magnetic field strength:
in the frequency range from 100 kHz do 1 GHz Range (0,010 – 16,0) A/m in the frequency range from 300 kHz do 35 MHz Range (0,010 – 16,0) A/m w zakresie częstotliwości od 20 MHz do 1 GHz Range (0,010 – 10,0) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 3
12 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Magnetic field strength:
w zakresie częstotliwości: od 0,8 GHz do 90 GHz from 1 GHz do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 3
13 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength:
in the frequency range from 10 Hz do 1 kHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
14 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density:
in the frequency range from 10 Hz do 1 kHz Range 1,25 µT – 19 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method (simplified) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
15 Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Electric field strength:
w zakresie częstotliwości od 45 Hz od 55 Hz Range 1 V/m – 49,0 kV/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
16 Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Magnetic field strength:
w zakresie częstotliwości od 45 Hz od 55 Hz (z obliczeń)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
17 Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Magnetic flux density:
in the frequency range from 45 Hz do 55 kHz Range 1,25 µT – 19 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
18 Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations) Electric field strength:
in the frequency range from 100 kHz do 3,6 GHz Range (0,5 – 1000) V/m in the frequency range from 3 GHz do 90 GHz Range (0,5 – 350) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
19 Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations) Magnetic field strength:
in the frequency range from 80 MHz do 1 GHz Range (0,010 – 10) A/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
20 Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations) Magnetic field strength:
in the frequency range from 0,8 GHz do 90 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
21 Workplace environment - electromagnetic field in the workspace originating from radiocommunication transmitting equipment (broadcasting and radiocommunication transmitting systems - radio, television, etc.) Electric field strength:
in the frequency range from 100 kHz do 3 GHz Range (0,5 – 1000) V/m in the frequency range from 3 GHz do 90 GHz Range (0,5 – 248) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
22 Workplace environment - electromagnetic field in the workspace originating from radiocommunication transmitting equipment (broadcasting and radiocommunication transmitting systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 300 kHz do 35 MHz Range (0,010 – 16) A/m w zakresie częstotliwości od 20 MHz do 1 GHz Range (0,010 – 10) A/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
23 Workplace environment - electromagnetic field in the workspace originating from radiocommunication transmitting equipment (broadcasting and radiocommunication transmitting systems - radio, television, etc.) Magnetic flux density:
in the frequency range from 100 kHz do 300 kHz Range (0,1 – 41,0) µT
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
24 Workplace environment - electromagnetic field in the workspace originating from radiocommunication transmitting equipment (broadcasting and radiocommunication transmitting systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 100 kHz do 300 kHz od 0,8 GHz do 90 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
25 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength:
in the frequency range 50 Hz Range 1 V/m – 49 kV/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
26 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density:
in the frequency range 50 Hz Range 0,1 µT – 19 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
27 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength:
in the frequency range 50 Hz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
28 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
in the frequency range from 100 kHz do 3,6 GHz Range (0,5 – 1000) V/m w zakresie częstotliwości od 3,0 GHz do 90 GHz Range (0,5 – 350) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
29 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic flux density:
in the frequency range from 100 kHz do 300 kHz Range (0,1 – 41,0) µT
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
30 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 300 kHz do 10 MHz Range (0,010 – 16) A/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
31 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 100 kHz do 300 kHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
32 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 10 MHz do 90 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt 3 załącznika do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
33 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (26 – 136) dB C-weighted peak sound pressure level Range (28 – 136) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 oraz strategię 3 – punkt 11
34 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 oraz strategię 3 – punkt 11
35 Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,5 – 60) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
36 Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
37 Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,03 – 35,5) m/s²
Direct measurement method PN-EN 14253+A1:2011
38 Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
39 Workplace environment – hot microclimate Air temperature
Range (10 – 60) °C Natural wet bulb temperature Range (10 – 60) °C Black globe temperature Range (10 – 60) °C
Direct measurement method PN-EN ISO 7243:2018-01
40 Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
41 Workplace environment – cold microclimate Air temperature
Range (-30 – 10) °C Black globe temperature Range (-30 – 10) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 10) m/s
Direct measurement method PN-EN ISO 11079:2008
42 Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
43 Workplace environment – moderate microclimate Air temperature
Range (10 – 30) °C Black globe temperature Range (10 – 40) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 1) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
44 Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
45 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (26 – 136) dB
Direct measurement method Załącznik nr 7 do Rozporządzenia Ministra Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem punktu F
46 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem punktu F
47 Workplace environment – indoor electric lighting Illuminance
Range (0,5 – 9800) lx
Direct measurement method PN-83/E-04040.03
48 Workplace environment – indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
49 Workplace environment – outdoor electric lighting Illuminance
Range (0,5 – 9800) lx
Direct measurement method PN-83/E-04040.03
50 Workplace environment – outdoor electric lighting Ratio of minimum to maximum illuminance (calculated) PN-83/E-04040.03
51 Workplace environment – outdoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
52 Workplace environment – emergency lighting Illuminance
Range (0,5 – 500) lx
Direct measurement method PN-83/E-04040.03 | PN-EN 1838:2025-05 z wyłączeniem punktów 5.1.3 – 5.1.9, 5.2.3 – 5.2.7, 5.3.4 – 5.3.8, 6, 7.2
53 Workplace environment – emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-83/E-04040.03 | PN-EN 1838:2025-05 z wyłączeniem punktów 5.1.3 – 5.1.9, 5.2.3 – 5.2.7, 5.3.4 – 5.3.8, 6, 7.2
54 Workplace environment – energy expenditure Air temperature
Range (0 – 60) °C Air flow Range (10 – 60) dm3/min
Direct measurement method PB-02 wydanie 6 z dnia 11.02.2025 r.
55 Workplace environment – energy expenditure Energy expenditure (calculated) PB-02 wydanie 6 z dnia 11.02.2025 r.
56 Workplace environment – air Sampling for assessment of occupational exposure to: − dust agents
inhalable fraction frakcja respirabilna − substancje nieorganiczne, w tym respirable fraction − organic substances, including frakcja wdychalna − metale i ich związki, w tym inhalable fraction respirable fraction
Personal dosimetry method PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004
57 Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004
58 Workplace environment – air Concentration of harmful dust agents - inhalable fraction:
Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,12 – 17,0) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
59 Workplace environment – air Concentration of harmful dust agents - respirable fraction:
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,12 – 15,4) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08

Reference standards (29)

Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 1
Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 2
Instrukcja I-05 wydanie 10 z dnia 02.06.2025 r., Załącznik nr 3
PB-02 wydanie 6 z dnia 11.02.2025 r.
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN 1838:2025-05 z wyłączeniem punktów 5.1.3 – 5.1.9, 5.2.3 – 5.2.7, 5.3.4 – 5.3.8, 6, 7.2
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 oraz strategię 3 – punkt 11
PN-N-01307:1994
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
PN-Z-04008-7:2002
PN-Z-04008-7:2002/Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
Punkt 3 załącznika do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik nr 7 do Rozporządzenia Ministra Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem punktu F