🇵🇱 ZAKŁAD WODOCIĄGÓW I KANALIZACJI PL

PCA AB 1563 • Łomianki, Poland • 26 methods

Water & wastewaterMicrobiology

ZAKŁAD WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 1563 (Łomianki, Poland). Its accreditation scope covers 26 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water intended for human consumption Wastewater, Wastewater.

At a glance

  • Accreditation number: PCA AB 1563
  • Methods in scope: 26
  • Types of test objects: 3
  • City: Łomianki, Poland
Accreditation number
AB 1563
Accreditation body
PCA
Address
W ŁOMIANKACH SP. Z O.O., ul. Rolnicza 244, 05-092 Łomianki, LABORATORIUM BADANIA WODY I ŚCIEKÓW
City
Łomianki, Poland

What this laboratory tests (3)

Accreditation scope — test methods (26)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
2 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
3 Water intended for human consumption Iron concentration Range: (0,06 – 3,0) mg/l Spectrophotometric method PB-06 wydanie 2 z dnia 19.11.2014 r. na podstawie testu Hach 8008
4 Water intended for human consumption Manganese concentration Range: (0,015 – 1,5) mg/l Spectrophotometric method PB-01 wydanie 3 z dnia 27.04.2018 r. na podstawie testu Merck 1.14770.0001
5 Water intended for human consumption Free chlorine concentration Range: (0,05 – 1,00) mg/l Spectrophotometric method PB-02 wydanie 2 z dnia 19.11.2014 r. na podstawie testu Hach 8021
6 Water intended for human consumption Total calcium and magnesium content (total hardness) Range: (20 – 700) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
7 Water intended for human consumption Colour Range: (4 – 70) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 p.6 +Ap1:2015-06
8 Water intended for human consumption Turbidity Range: (0,30 – 100) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
9 Water intended for human consumption MPN of coliform bacteria Colilert-18 test method PN-EN ISO 9308-2:2014-06
10 Water intended for human consumption MPN of Escherichia coli Colilert-18 test method
11 Water intended for human consumption MPN of intestinal enterococci Enterolert-DW test method PB-07 wydanie 4 z dnia 31.01.2019 r. na podstawie testu firmy IDEXX
12 Wastewater Sampling for chemical and physical testing Manual method Automatic method PN-ISO 5667-10:2021-11
13 Wastewater Chemical oxygen demand - COD-Cr Range: (20,0 – 1000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
14 Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 3000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
15 Wastewater Biochemical oxygen demand - BOD 5 Range: (2,0 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
16 Wastewater Total phosphorus concentration Range: (0,20 – 25,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
17 Wastewater Total nitrogen concentration Range: (2,0 – 200) mg/l Spectrophotometric method PB-03 wydanie 4 z dnia 27.04.2018 r. na podstawie testu kuwetowego Hach-Lange LCK 138; LCK 238; LCK 338
18 Wastewater Total suspended solids (TSS) Range: (2,0 – 1000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
19 Water intended for human consumption Wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012
20 Water intended for human consumption Wastewater Electrical conductivity Range: (80 – 12 880) µS/cm Conductometric method PN-EN 27888:1999
21 Water intended for human consumption Wastewater Nitrate concentration Range: (2 – 60) mg/l Nitrate nitrogen concentration Range: (0,45 – 13,5) mg/l Spectrophotometric method PB-04 wydanie 1 z dnia 30.01.2014 r. na podstawie testu kuwetowego Hach-Lange LCK 339
22 Water intended for human consumption Wastewater Ammonium ion concentration Range: (0,10 – 2,50) mg/l Ammonium nitrogen concentration Range: (0,08 – 2,0) mg/l Spectrophotometric method PB-05 wydanie 2 z dnia 30.01.2015 r. na podstawie testu kuwetowego Hach-Lange LCK 304
23 Water intended for human consumption Wastewater Ammonium ion concentration Range: (0,07 – 205) mg/l Ammonium nitrogen concentration Range: (0,05 – 160) mg/l Spectrophotometric method PN-ISO 7150-1:2002
24 Water intended for human consumption Wastewater Nitrite concentration Range: (0,020 – 16,0) mg/l Nitrite nitrogen concentration Range: (0,006 – 5,0) mg/l Spectrophotometric method PN-EN 26777:1999
25 Water intended for human consumption Wastewater Chloride concentration Range: (5,0 – 400) mg/l Titrimetric method PN-ISO 9297:1994
26 Water intended for human consumption Wastewater Iron concentration Range: (0,020 – 10,0) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06

Reference standards (25)

PB-01 wydanie 3 z dnia 27.04.2018 r. na podstawie testu Merck 1.14770.0001
PB-02 wydanie 2 z dnia 19.11.2014 r. na podstawie testu Hach 8021
PB-03 wydanie 4 z dnia 27.04.2018 r. na podstawie testu kuwetowego Hach-Lange LCK 138; LCK 238; LCK 338
PB-04 wydanie 1 z dnia 30.01.2014 r. na podstawie testu kuwetowego Hach-Lange LCK 339
PB-05 wydanie 2 z dnia 30.01.2015 r. na podstawie testu kuwetowego Hach-Lange LCK 304
PB-06 wydanie 2 z dnia 19.11.2014 r. na podstawie testu Hach 8008
PB-07 wydanie 4 z dnia 31.01.2019 r. na podstawie testu firmy IDEXX
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p.6 +Ap1:2015-06
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994