🇵🇱 INSTYTUT BADAWCZY DRÓG i MOSTÓW PL
ConstructionMaterials & polymers
INSTYTUT BADAWCZY DRÓG i MOSTÓW is a laboratory accredited by PCA under number AB 1562 (Kielce, Poland). Its accreditation scope covers 13 test methods in the following areas: Construction, Materials & polymers. Test objects include: Construction works – bridge structures (railway engineering structu…, Metal products and materials: - steel for concrete reinforcement, Bars, wire rod and wire for the reinforcement of concrete, Metals. Most frequently used techniques: Method: tensile test at room temperature.
At a glance
- Accreditation number: PCA AB 1562
- Methods in scope: 13
- Types of test objects: 6
- Techniques used: 1
- City: Kielce, Poland
- Accreditation number
- AB 1562
- Accreditation body
- PCA
- Address
- ul. Instytutowa 1; 03-302 Warszawa, LABORATORIUM BADAŃ MATERIAŁÓW I KONSTRUKCJI MOSTOWYCH, ul. Chorzowska 28; 25-852 Kielce
- City
- Kielce, Poland
What this laboratory tests (6)
- Construction works – bridge structures (railway engineering structures and road engineering structures) — 7 methods
- Metal products and materials: - steel for concrete reinforcement — 2 methods
- Bars, wire rod and wire for the reinforcement of concrete — 1 method
- Metals — 1 method
- Prestressing steel — 1 method
- Welded reinforcing fabric — 1 method
Analytical techniques used (1)
- Method: tensile test at room temperature — 4 methods
Accreditation scope — test methods (13)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of vertical displacements under static load Range ± 50 mm Location of the reference point do 20 m Measurement using displacement sensors |
PB/TK-2/1 wydanie 3 z dnia 07.01.2015 r. | ||
| 2 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of vertical displacements under static load Range do 50 mm Location of the reference point do 40 m (horizontal) Measurement using precise levelling |
PB/TK-2/2 wydanie 3 z dnia 07.01.2015 r. | ||
| 3 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of support settlements under static load Range do 50 mm Location of the reference point do 40 m (horizontal) Measurement using precise levelling |
PB/TK-2/2 wydanie 3 z dnia 07.01.2015 r. | ||
| 4 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of unit strains under static load Range ± 2000 μm/m Measurement using electrical resistance strain gauges |
PB/TK-2/4 wydanie 2 z dnia 01.07.2016 r. | ||
| 5 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of vertical displacements under dynamic load, Range ± 50 mm, Reference point location up to 10 m (vertically), Measurement using displacement transducers | PB/TK-2/1 wydanie 3 z dnia 07.01.2015 r. | ||
| 6 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of vibration accelerations of structural elements under dynamic loading amplitudes: ± 10 m/s2 frequency (0,5 – 20) Hz Measurement using accelerometers |
PB/TK-2/3 wydanie 2 z dnia 01.06.2015 r. | ||
| 7 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of unit strains under dynamic load Range ± 2000 μm/m Measurement using electrical resistance strain gauges |
PB/TK-2/4 wydanie 2 z dnia 01.07.2016 r. | ||
| 8 | Metals | Mechanical properties: tensile strength Rm distinct yield strength Re proof strength, plastic extension Rp elongation A, Agt Force range do 1000 kN |
Method: tensile test at room temperature | PN-EN ISO 6892-1:2020-05 metoda B | |
| 9 | Bars, wire rod and wire for the reinforcement of concrete | Mechanical properties: tensile strength Rm distinct yield strength Re proof strength, plastic extension Rp elongation A, Agt Force range do 1000 kN |
Method: tensile test at room temperature | PN-EN ISO 6892-1:2020-05 metoda B | PN-EN ISO 15630-1:2019-04 p.5 | |
| 10 | Welded reinforcing fabric | Mechanical properties: tensile strength Rm distinct yield strength Re proof strength, plastic extension Rp elongation A, Agt Force range do 1000 kN |
Method: tensile test at room temperature | PN-EN ISO 6892-1:2020-05 metoda B | PN-EN ISO 15630-2: 2019-04 p.5 | |
| 11 | Prestressing steel | Mechanical properties: tensile strength Rm distinct yield strength Re proof strength, plastic extension Rp elongation A, Agt Force range do 1000 kN |
Method: tensile test at room temperature | PN-EN ISO 6892-1:2020-05 metoda B | PN-EN ISO 15630-3: 2019-04 p.5 | |
| 12 | Metal products and materials: - steel for concrete reinforcement | Ability to undergo plastic deformation – bending, Bend test | PN-EN ISO 15630-1: 2019-04 pkt 6 | ||
| 13 | Metal products and materials: - steel for concrete reinforcement | Ability to undergo plastic deformation – unbending, Unbending test | PN-EN ISO 15630-1: 2019-04 pkt 7 | ||
Reference standards (10)
PB/TK-2/1 wydanie 3 z dnia 07.01.2015 r.
PB/TK-2/2 wydanie 3 z dnia 07.01.2015 r.
PB/TK-2/3 wydanie 2 z dnia 01.06.2015 r.
PB/TK-2/4 wydanie 2 z dnia 01.07.2016 r.
PN-EN ISO 15630-1: 2019-04 pkt 6
PN-EN ISO 15630-1: 2019-04 pkt 7
PN-EN ISO 15630-1:2019-04 p.5
PN-EN ISO 15630-2: 2019-04 p.5
PN-EN ISO 15630-3: 2019-04 p.5
PN-EN ISO 6892-1:2020-05 metoda B