🇵🇱 Centrum Ochrony Pracy „PERFEX” Sp. z o.o. PL
Environment
Centrum Ochrony Pracy „PERFEX” Sp. z o.o. is a laboratory accredited by PCA under number AB 1509 (Lębork, Poland). Its accreditation scope covers 38 test methods in the following areas: Environment. Test objects include: Workplace environment –cold microclimate, Workplace environment - air, Workplace environment –hot microclimate, Workplace environment - noise. Most frequently used techniques: Direct measurement method, Gravimetric method, Electrochemical method.
At a glance
- Accreditation number: PCA AB 1509
- Methods in scope: 38
- Types of test objects: 10
- Techniques used: 4
- City: Lębork, Poland
- Accreditation number
- AB 1509
- Accreditation body
- PCA
- Address
- Laboratorium Badań i Pomiarów Środowiska Pracy, ul. Staromiejska 4/1, 84-300 Lębork
- City
- Lębork, Poland
What this laboratory tests (10)
- Workplace environment –cold microclimate — 7 methods
- Workplace environment - air — 5 methods
- Workplace environment –hot microclimate — 5 methods
- Workplace environment - noise — 4 methods
- Workplace environment – moderate microclimate — 4 methods
- Workplace environment – emergency lighting — 3 methods
- Workplace environment – hand-arm vibration — 3 methods
- Workplace environment – whole-body vibration — 3 methods
- Workplace environment -energy expenditure — 2 methods
- Workplace environment – indoor electric lighting — 2 methods
Analytical techniques used (4)
- Direct measurement method — 20 methods
- Gravimetric method — 2 methods
- Electrochemical method — 1 method
- Personal dosimetry method — 1 method
Laboratory locations
- Laboratorium Badań i Pomiarów Środowiska Pracy — ul. Staromiejska 4/1, 84-300 Lębork
Accreditation scope — test methods (38)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium Badań i Pomiarów Środowiska Pracy | |||||
| 1 | Workplace environment - noise | A-weighted equivalent sound pressure level Range (50-136) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | |
| 2 | Workplace environment - noise | Maximum A-weighted sound pressure level Range (50-136) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | |
| 3 | Workplace environment - noise | C-weighted peak sound pressure level Range (50-139) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | |
| 4 | Workplace environment - noise | Noise exposure level normalised to: (calculated) an 8-hour daily working time average weekly working time |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | ||
| 5 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 6 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 7 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction: apatites and phosphorites petroleum bitumen portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica pył drewna pył mąki dusts not classified according to toxicity pyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki calcium sulfate (VI) (gypsum) carbon black coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range (0,09 – 40,8) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 8 | Workplace environment - air | Stężenie pyłowych czynników szkodli-wych dla zdrowia – frakcja respirabilna: apatites and phosphorites portland cement natural graphite krzemionka bezpostaciowa i syntetycz-na pyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki coal (hard, brown) Range (0,07 – 13,5) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 9 | Workplace environment - air | Carbon monoxide concentration Range (2,3-232) mg/m3 Range (2-200) ppm |
Electrochemical method | PB-01 wydanie 3 z dnia 09.12.2024 r. | |
| 10 | Workplace environment – hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,32 – 100) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015 | |
| 11 | Workplace environment – hand-arm vibration | Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015 | ||
| 12 | Workplace environment – hand-arm vibration | Exposure lasting 30 minutes and less, expressed as the vector sum of root-mean-square, frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015 | ||
| 13 | Workplace environment – whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,03 - 35) m/s² |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 14 | Workplace environment – whole-body vibration | Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczo-nych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) | PN-EN 14253+A1:2011 | ||
| 15 | Workplace environment – whole-body vibration | Exposure lasting 30 minutes or less, expressed as the frequency-weighted r.m.s. vibration acceleration, dominant among the vibration accelerations determined for the three directional components with the appropriate factors applied (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 16 | Workplace environment –hot microclimate | Air temperature Range (10 – 60) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 17 | Workplace environment –hot microclimate | Natural wet bulb temperature Range (10 – 40) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 18 | Workplace environment –hot microclimate | Black globe temperature Range (10 – 60) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 19 | Workplace environment –hot microclimate | WBGT index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 20 | Workplace environment –hot microclimate | WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 21 | Workplace environment – moderate microclimate | Air temperature Range (10 – 30) o C |
Direct measurement method | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | |
| 22 | Workplace environment – moderate microclimate | Black globe temperature Range (10 - 30) °C |
Direct measurement method | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | |
| 23 | Workplace environment – moderate microclimate | Air humidity Range (20 – 90) % |
Direct measurement method | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | |
| 24 | Workplace environment – moderate microclimate | Air velocity Range (0,15 – 1) m/s |
Direct measurement method | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | |
| 25 | Workplace environment –cold microclimate | Air temperature Range (-30 – +10) °C |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 26 | Workplace environment –cold microclimate | Black globe temperature Range (-30 – +15) °C |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 27 | Workplace environment –cold microclimate | Air humidity Range (20 – 90) % |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 28 | Workplace environment –cold microclimate | Air velocity Range (0,15 – 5) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 29 | Workplace environment –cold microclimate | Wskaźnik tWC (z obliczeń) | PN-EN ISO 11079:2008 | ||
| 30 | Workplace environment –cold microclimate | Wskaźnik IREQmin (z obliczeń) | PN-EN ISO 11079:2008 | ||
| 31 | Workplace environment –cold microclimate | IREQneutral index (calculated) | PN-EN ISO 11079:2008 | ||
| 32 | Workplace environment – indoor electric lighting | Illuminance Range (5 - 5000) lx |
Direct measurement method | PN-83/E-04040/03 | PB-02 wydanie 2 z dnia 09.12.2024 r. | |
| 33 | Workplace environment – indoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040/03 | PB-02 wydanie 2 z dnia 09.12.2024 r. | ||
| 34 | Workplace environment – emergency lighting | Illuminance Range (0,5 - 500) lx |
Direct measurement method | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7 4.3.3-4.3.7; 4.4.3-4.4.7; 4.5 i 5 | |
| 35 | Workplace environment – emergency lighting | Stosunek minimalnego do maksymalne-go natężenia oświetlenia (z obliczeń) | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7 4.3.3-4.3.7; 4.4.3-4.4.7; 4.5 i 5 | ||
| 36 | Workplace environment – emergency lighting | Illuminance uniformity for the high-risk zone (calculated) | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7 4.3.3-4.3.7; 4.4.3-4.4.7; 4.5 i 5 | ||
| 37 | Workplace environment -energy expenditure | Air temperature Range (0 - 60) o C |
Direct measurement method | PB-03 wydanie 2 z dnia 09.12.2024 r. | |
| 38 | Workplace environment -energy expenditure | Air flow Range (10 - 60) dm3/min |
Direct measurement method | PB-03 wydanie 2 z dnia 09.12.2024 r. | |
Reference standards (20)
PB-01 wydanie 3 z dnia 09.12.2024 r.
PB-02 wydanie 2 z dnia 09.12.2024 r.
PB-03 wydanie 2 z dnia 09.12.2024 r.
PN-83/E-04040/03
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7 4.3.3-4.3.7; 4.4.3-4.4.7; 4.5 i 5
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004+A1:2015
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08