🇵🇱 M-LAB Mirosław Pracki PL
EnvironmentConstruction
M-LAB Mirosław Pracki is a laboratory accredited by PCA under number AB 1498 (Piechcin, Poland). Its accreditation scope covers 20 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment - air, Workplace environment – indoor electric lighting, General environment – noise from installations, equipment and indus…, Workplace environment - noise.
At a glance
- Accreditation number: PCA AB 1498
- Methods in scope: 20
- Types of test objects: 6
- City: Piechcin, Poland
- Accreditation number
- AB 1498
- Accreditation body
- PCA
- Address
- ul. Barcińska 18, 88-170 Pakość, LABORATORIUM M-LAB, ul. Gazowa 2/2, 88-192 Piechcin
- City
- Piechcin, Poland
What this laboratory tests (6)
- Workplace environment - air — 7 methods
- Workplace environment – indoor electric lighting — 5 methods
- General environment – noise from installations, equipment and industrial plants — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment − hand-arm vibration — 2 methods
- Workplace environment − whole-body vibration — 2 methods
Accreditation scope — test methods (20)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - noise | A-weighted equivalent sound level A-weighted maximum sound level C-weighted peak sound level Range: (28 - 137) dB Direct measurement method | PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | ||
| 2 | Workplace environment - noise | Noise exposure level referred to: - an 8-hour daily working time - an average weekly working time (calculated) | |||
| 3 | Workplace environment – indoor electric lighting | Illuminance | PN-83/E-04040.03 | ||
| 4 | Workplace environment – indoor electric lighting | Range: (5 - 5000) lx | |||
| 5 | Workplace environment – indoor electric lighting | Direct measurement method | |||
| 6 | Workplace environment – indoor electric lighting | Illuminance uniformity | |||
| 7 | Workplace environment – indoor electric lighting | (calculated) | |||
| 8 | Workplace environment - air | Sampling for occupational exposure assessment to: - dust agents inhalable fraction respirable fraction - organic substances, including inhalable fraction - inorganic substances, including inhalable fraction respirable fraction - metals and their compounds, including inhalable fraction respirable fraction Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | ||
| 9 | Workplace environment - air | Exposure index (calculated) | |||
| 10 | Workplace environment - air | Carbon monoxide concentration Range: (2,3 - 1147,2) mg/m3 (2,0 - 989) ppm Electrochemical method | PB-01 wydanie 3 z dnia 03.11.2025 r. | ||
| 11 | Workplace environment - air | Carbon dioxide concentration Range: (895 - 18333) mg/m3 (489 - 10018) ppm Non-dispersive infrared spectrometry method (NDIR) | |||
| 12 | Workplace environment - air | Exposure indices (calculated) | |||
| 13 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction: - Apatites and phosphorites - Portland cement - Titanium dioxide - Natural graphite - Synthetic graphite - Kaolin - Amorphous and synthetic silica: - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Carbon black - Talc - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Silicon carbide, non-fibrous Range: (0,2 - 37) mg/m3 Gravimetric method | PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08 | ||
| 14 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction: - Apatites and phosphorites - Portland cement - Natural graphite - Amorphous and synthetic silica: - Organic dusts of animal and plant origin except wood and flour dust - Talc - Coal (hard, brown) Range: (0,2 - 37) mg/m3 Gravimetric method | PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08 | ||
| 15 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound level Range: (28 - 137) dB Direct measurement method | nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F | ||
| 16 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | |||
| 17 | Workplace environment − whole-body vibration | Frequency-weighted effective vibration acceleration Range: (0,03 - 25) ms-2 Direct measurement method | PN-EN 14253+A1:2011 | ||
| 18 | Workplace environment − whole-body vibration | Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) (calculated) | |||
| 19 | Workplace environment − hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range: (0,32 - 100) ms-2 Direct measurement method | PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-1:2004+A1:2015-11 | ||
| 20 | Workplace environment − hand-arm vibration | Daily exposure, expressed as the 8-hour energy-equivalent vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) Exposure lasting 30 minutes and less, expressed as the vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) | |||
Reference standards (10)
PB-01 wydanie 3 z dnia 03.11.2025 r.
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-1:2004+A1:2015-11
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F
nr 7