🇵🇱 SIEĆ BADAWCZA ŁUKASIEWICZ - PL
Materials & polymers
SIEĆ BADAWCZA ŁUKASIEWICZ - is a laboratory accredited by PCA under number AB 1490 (Warszawa, Poland). Its accreditation scope covers 14 test methods in the following areas: Materials & polymers. Test objects include: Composites E, Composites E Plastics E.
At a glance
- Accreditation number: PCA AB 1490
- Methods in scope: 14
- Types of test objects: 2
- City: Warszawa, Poland
- Accreditation number
- AB 1490
- Accreditation body
- PCA
- Address
- INSTYTUT LOTNICTWA, LABORATORIUM BADAŃ KOMPOZYTÓW, Al. Krakowska 110/114
- City
- Warszawa, Poland
What this laboratory tests (2)
- Composites E — 11 methods
- Composites E Plastics E — 3 methods
Accreditation scope — test methods (14)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Composites E | Shear - Shear strength - Shear modulus Load range: (0 – 200) kN Temperature range: from - 55 °C to +149 °C Static in-plane shear test Static short-beam shear test Static V-notched shear test | ASTM D2344/D2344M ASTM D3518/D3518M ASTM D7078/D7078M PN-EN ISO 14129 PN-EN ISO 14130 | ||
| 2 | Composites E | Tension - Tensile strength - Tensile modulus - Poisson's ratio Load range: (0 – 200) kN Temperature range: from - 55 °C to +149 °C Static tension test Open-hole tension test | PN-EN ISO 527-1 PN-EN ISO 527-4 PN-EN ISO 527-5 | ||
| 3 | Composites E | Flexure - Flexural strength - Flexural modulus Load range: (0 – 200) kN Temperature range: from - 55 °C to +149 °C Static flexure test | PN-EN ISO 14125 PN-EN ISO 14125 | ||
| 4 | Composites E | Compression - Compressive strength - Compressive modulus - Poisson's ratio Load range: (0 – 200) kN Temperature range: from - 55°C to +149°C Static compression test Open-hole compression test | ASTM D3410/D3410M ASTM D6641/D6641M ASTM D6484/D6484M procedura B PN-EN ISO 14126 | ||
| 5 | Composites E | Compression after impact - Compression-after-impact strength Load range: (0 – 200) kN Temperature range: from - 55 °C to +149 °C Static compression after impact test | ASTM D7136/D7136M ASTM D7137/D7137M ISO 18352 | ||
| 6 | Composites E | Interlaminar fracture - Critical energy release rate - G Ic Load range: (0 – 2000) N Static mode I fracture test Fatigue mode I fracture test | ASTM D5528/D5528M ASTM D6115 PN-EN 6033 ISO 15024 | ||
| 7 | Composites E | Bearing response - Bearing strength Load range: (0 – 200) kN Temperature range: from - 55 °C to +149 °C Static tensile test of pin joints Bearing response - Bearing strength Load range: (0 – 200) kN Temperature range: from - 55 °C to +149 °C Static bearing test | ASTM D5961/D5961M | ||
| 8 | Composites E | Sandwich flexure - Facesheet flexure strength - Facesheet stiffness Load range: (0 – 200) kN Temperature range: from - 55°C to +149°C Static long-beam flexure test | ASTM D7249/D7249M | ||
| 9 | Composites E | Flatwise tension - Flatwise tensile strength Load range: (0 – 200) kN Temperature range: from - 55 °C to +149 °C Static flatwise tension test | ASTM C297/C297M | ||
| 10 | Composites E | Fastener pull-through - Pull-through resistance Load range: (0 – 200) kN Temperature range: from - 55 °C to +149 °C Static fastener pull-through test | ASTM D7332/D7332M | ||
| 11 | Composites E | Constituent Content of Composite Materials: - Reinforcement Content (Weight Percent, Volume Percent) - Matrix Content (Weight Percent, Volume Percent) - Void Volume | ASTM D3171 Metoda 1, proc. B | ||
| 12 | Composites E Plastics E | Density testing: - determination of density and specific gravity Lower limit of determination: 0,1 g/cm3 Density: - density and Specific Gravity (Relative Density) Lower range of determination: 0,1 g/cm3 | ASTM D792 proc. A | ||
| 13 | Composites E Plastics E | Calorimetric testing (DSC): - Enthalpy of melting and crystallisation - Melting and crystallisation temperature - Glass transition temperature Test temperature range: from - 40 ˚C to + 500 ˚C Differential Scanning Calorimetry (DSC): - Enthalpies of melting and crystalization - Melting and crystalization temperaturę - Glass transition temperature Temperature range: from - 40 ˚C to + 500 ˚C | PN-EN ISO 11357-1 PN-EN-ISO 11357-2 PN-EN-ISO 11357-3 | ||
| 14 | Composites E Plastics E | Dynamic Mechanical Analysis (DMA): - Glass transition temperature Temperature range: from - 160 ˚C to + 600 ˚C | PN-EN ISO 6721-1 ISO 6721-5 ISO 6721-11 | ||
Reference standards (14)
ASTM C297/C297M
ASTM D2344/D2344M ASTM D3518/D3518M ASTM D7078/D7078M PN-EN ISO 14129 PN-EN ISO 14130
ASTM D3171 Metoda 1, proc. B
ASTM D3410/D3410M ASTM D6641/D6641M ASTM D6484/D6484M procedura B PN-EN ISO 14126
ASTM D5528/D5528M ASTM D6115 PN-EN 6033 ISO 15024
ASTM D5961/D5961M
ASTM D7136/D7136M ASTM D7137/D7137M ISO 18352
ASTM D7249/D7249M
ASTM D7332/D7332M
ASTM D792 proc. A
PN-EN ISO 11357-1 PN-EN-ISO 11357-2 PN-EN-ISO 11357-3
PN-EN ISO 14125 PN-EN ISO 14125
PN-EN ISO 527-1 PN-EN ISO 527-4 PN-EN ISO 527-5
PN-EN ISO 6721-1 ISO 6721-5 ISO 6721-11