Electronics & EMC
WOJSKOWY INSTYTUT ŁĄCZNOŚCI is a laboratory accredited by PCA under number AB 149 (Zegrze Południowe, Poland). Its accreditation scope covers 18 test methods in the following areas: Electronics & EMC. Test objects include: Electrical, electromechanical and electronic equipment or sets of e…, Electronic and telecommunications equipment, Antennas, Data carrier image.
At a glance
- Accreditation number: PCA AB 149
- Methods in scope: 18
- Types of test objects: 7
- City: Zegrze Południowe, Poland
- Accreditation number
- AB 149
- Accreditation body
- PCA
- Address
- IM. PROF. DR. HAB. JANUSZA GROSZKOWSKIEGO, PAŃSTWOWY INSTYTUT BADAWCZY, LABORATORIUM WIŁ - PIB
- City
- Zegrze Południowe, Poland
What this laboratory tests (7)
- Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces — 8 methods
- Electronic and telecommunications equipment — 5 methods
- Antennas — 1 method
- Data carrier image — 1 method
- Filters — 1 method
- Shielding enclosures with internal dimensions of min. (1,5x1,5x1,5) m — 1 method
- Vehicles and other equipment powered by internal combustion engines — 1 method
Accreditation scope — test methods (18)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces | Radiated electromagnetic disturbances (magnetic field), in the frequency range from 30 Hz to 100 kHz. | NO-06-A500:2012 p.3.13 | ||
| 2 | Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces | Radiated electromagnetic disturbances (electric field), in the frequency range from 10 kHz to 18 GHz. | NO-06-A500:2012 p.3.14 | ||
| 3 | Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces | Conducted disturbances on power supply lines, in the frequency range from 30 Hz to 10 kHz. | NO-06-A500:2012 p.3.1 | ||
| 4 | Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces | Conducted disturbances on power supply lines, in the frequency range from 10 kHz to 10 MHz. | NO-06-A500:2012 p.3.2 | ||
| 5 | Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces | Immunity to electrostatic discharge | PN-EN 61000-4-2:2011 | ||
| 6 | Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces | Immunity to radiated disturbances (electric field), in the frequency range from 2 MHz to 18 GHz. | NO-06-A500:2012 p.3.17 | ||
| 7 | Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces | Immunity to conducted disturbances in power and signal lines, in the frequency range from 10 kHz to 200 MHz. | NO-06-A500:2012 p.3.9 | ||
| 8 | Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces | Immunity to conducted disturbances in power lines, in the frequency range from 30 Hz to 150 kHz. | NO-06-A500:2012 p.3.4 | ||
| 9 | Shielding enclosures with internal dimensions of min. (1,5x1,5x1,5) m | Shielding effectiveness of shielding structures, in the frequency range from 10 kHz to 1GHz. | NO-06-A501 | ||
| 10 | Filters | Insertion loss of filters, in the frequency range from 10 kHz to 1 GHz | PB-01-03 | enność filtrów” (w oparciu o PN-CISPR 17:2000 p. 4.1) | ||
| 11 | Vehicles and other equipment powered by internal combustion engines | Electromagnetic disturbances, in the frequency range from 30 MHz to 1 GHz. | EN 55012:2012 | ||
| 12 | Antennas | Directional radiation pattern, in the frequency range from 30 MHz to 18 GHz. | PB-06-01 | eny - kierunkowa charakterystyka promieniowania” | ||
| 13 | Electronic and telecommunications equipment | Resistance to ambient temperature changes (thermal shock) Range: (-60 ÷ +95) °C | NO-06-A107 | NO-A-STANAG-4370/AECTP-300- | ||
| 14 | Electronic and telecommunications equipment | Total resistance to increased humidity (damp heat), Range: (80 ÷ 98)% (+25 ÷ +55) °C | NO-06-A107 | NO-A-STANAG-4370/AECTP- | ||
| 15 | Electronic and telecommunications equipment | Total resistance to reduced ambient temperature (low temperature), Range: down to -60 °C | NO-06-A107 | NO-A-STANAG-4370/AECTP- | ||
| 16 | Electronic and telecommunications equipment | Resistance to condensation atmospheric deposits (frost and dew) | NO-06-A107:2021 p.4.10 | ||
| 17 | Electronic and telecommunications equipment | Total resistance to elevated ambient temperature (high temperature), Range: up to +95 °C | NO-06-A107 | NO-A-STANAG-4370/AECTP- | ||
| 18 | Data carrier image | Authenticity testing | PB-01 Wydanie I z 26.03.2018 r. | ||
Reference standards (19)
EN 55012:2012
NO-06-A107
NO-06-A107:2021 p.4.10
NO-06-A500:2012 p.3.1
NO-06-A500:2012 p.3.13
NO-06-A500:2012 p.3.14
NO-06-A500:2012 p.3.17
NO-06-A500:2012 p.3.2
NO-06-A500:2012 p.3.4
NO-06-A500:2012 p.3.9
NO-06-A501
NO-A-STANAG-4370/AECTP-
NO-A-STANAG-4370/AECTP-300-
PB-01 Wydanie I z 26.03.2018 r.
PB-01-03
PB-06-01
PN-EN 61000-4-2:2011
enność filtrów” (w oparciu o PN-CISPR 17:2000 p. 4.1)