🇵🇱 WOJSKOWY INSTYTUT ŁĄCZNOŚCI PL

PCA AB 149 • Zegrze Południowe, Poland • 18 methods

Electronics & EMC

WOJSKOWY INSTYTUT ŁĄCZNOŚCI is a laboratory accredited by PCA under number AB 149 (Zegrze Południowe, Poland). Its accreditation scope covers 18 test methods in the following areas: Electronics & EMC. Test objects include: Electrical, electromechanical and electronic equipment or sets of e…, Electronic and telecommunications equipment, Antennas, Data carrier image.

At a glance

  • Accreditation number: PCA AB 149
  • Methods in scope: 18
  • Types of test objects: 7
  • City: Zegrze Południowe, Poland
Accreditation number
AB 149
Accreditation body
PCA
Address
IM. PROF. DR. HAB. JANUSZA GROSZKOWSKIEGO, PAŃSTWOWY INSTYTUT BADAWCZY, LABORATORIUM WIŁ - PIB
City
Zegrze Południowe, Poland

What this laboratory tests (7)

Accreditation scope — test methods (18)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces Radiated electromagnetic disturbances (magnetic field), in the frequency range from 30 Hz to 100 kHz. NO-06-A500:2012 p.3.13
2 Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces Radiated electromagnetic disturbances (electric field), in the frequency range from 10 kHz to 18 GHz. NO-06-A500:2012 p.3.14
3 Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces Conducted disturbances on power supply lines, in the frequency range from 30 Hz to 10 kHz. NO-06-A500:2012 p.3.1
4 Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces Conducted disturbances on power supply lines, in the frequency range from 10 kHz to 10 MHz. NO-06-A500:2012 p.3.2
5 Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces Immunity to electrostatic discharge PN-EN 61000-4-2:2011
6 Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces Immunity to radiated disturbances (electric field), in the frequency range from 2 MHz to 18 GHz. NO-06-A500:2012 p.3.17
7 Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces Immunity to conducted disturbances in power and signal lines, in the frequency range from 10 kHz to 200 MHz. NO-06-A500:2012 p.3.9
8 Electrical, electromechanical and electronic equipment or sets of equipment intended for use in the Polish Armed Forces Immunity to conducted disturbances in power lines, in the frequency range from 30 Hz to 150 kHz. NO-06-A500:2012 p.3.4
9 Shielding enclosures with internal dimensions of min. (1,5x1,5x1,5) m Shielding effectiveness of shielding structures, in the frequency range from 10 kHz to 1GHz. NO-06-A501
10 Filters Insertion loss of filters, in the frequency range from 10 kHz to 1 GHz PB-01-03 | enność filtrów” (w oparciu o PN-CISPR 17:2000 p. 4.1)
11 Vehicles and other equipment powered by internal combustion engines Electromagnetic disturbances, in the frequency range from 30 MHz to 1 GHz. EN 55012:2012
12 Antennas Directional radiation pattern, in the frequency range from 30 MHz to 18 GHz. PB-06-01 | eny - kierunkowa charakterystyka promieniowania”
13 Electronic and telecommunications equipment Resistance to ambient temperature changes (thermal shock) Range: (-60 ÷ +95) °C NO-06-A107 | NO-A-STANAG-4370/AECTP-300-
14 Electronic and telecommunications equipment Total resistance to increased humidity (damp heat), Range: (80 ÷ 98)% (+25 ÷ +55) °C NO-06-A107 | NO-A-STANAG-4370/AECTP-
15 Electronic and telecommunications equipment Total resistance to reduced ambient temperature (low temperature), Range: down to -60 °C NO-06-A107 | NO-A-STANAG-4370/AECTP-
16 Electronic and telecommunications equipment Resistance to condensation atmospheric deposits (frost and dew) NO-06-A107:2021 p.4.10
17 Electronic and telecommunications equipment Total resistance to elevated ambient temperature (high temperature), Range: up to +95 °C NO-06-A107 | NO-A-STANAG-4370/AECTP-
18 Data carrier image Authenticity testing PB-01 Wydanie I z 26.03.2018 r.

Reference standards (19)

EN 55012:2012
NO-06-A107
NO-06-A107:2021 p.4.10
NO-06-A500:2012 p.3.1
NO-06-A500:2012 p.3.13
NO-06-A500:2012 p.3.14
NO-06-A500:2012 p.3.17
NO-06-A500:2012 p.3.2
NO-06-A500:2012 p.3.4
NO-06-A500:2012 p.3.9
NO-06-A501
NO-A-STANAG-4370/AECTP-
NO-A-STANAG-4370/AECTP-300-
PB-01 Wydanie I z 26.03.2018 r.
PB-01-03
PB-06-01
PN-EN 61000-4-2:2011
enność filtrów” (w oparciu o PN-CISPR 17:2000 p. 4.1)
eny - kierunkowa charakterystyka promieniowania”