🇵🇱 ITA-TEST Sp. z o.o. PL

PCA AB 1478 • Warszawa, Poland • 19 methods

Pharma & cosmeticsWater & wastewaterMicrobiology

ITA-TEST Sp. z o.o. is a laboratory accredited by PCA under number AB 1478 (Warszawa, Poland). Its accreditation scope covers 19 test methods in the following areas: Pharma & cosmetics, Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, water, Cosmetics, Cosmetics and household chemical products, Water intended for human consumption.

At a glance

  • Accreditation number: PCA AB 1478
  • Methods in scope: 19
  • Types of test objects: 4
  • City: Warszawa, Poland
Accreditation number
AB 1478
Accreditation body
PCA
Address
ul. Obozowa 82A lok.1, 01-434 Warszawa
City
Warszawa, Poland

What this laboratory tests (4)

Accreditation scope — test methods (19)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Issue No. 17, 21.11.2025 1/4
2 Water intended for human consumption, water Total count of microorganisms at a temperature of 22°C Plate method (pour plate) PN-EN ISO 6222:2004
3 Water intended for human consumption, water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014- 12 +A1:2017-04
4 Water intended for human consumption, water Escherichia coli count Membrane filtration method
5 Water intended for human consumption, water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
6 Water intended for human consumption, water Count of Clostridium perfringens including spores Membrane filtration method PN-EN ISO 14189:2016-10 z wyłączeniem punktu 8.2
7 Water intended for human consumption, water Count of bacteria of the genus Legionella Membrane filtration method] Matrix A Procedure 5, BCYE Procedure 7, GVPC PN-EN ISO 11731:2017-08 +Ap1:2019-12
8 Water intended for human consumption, water Sampling for microbiological testing PN-EN ISO 19458:2007
9 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 +Ap 1:2019-07
10 Water intended for human consumption Colour Range: (2,0 – 30) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda C
11 Cosmetics and household chemical products pH Range: 2,0 – 12,0 Potentiometric method PB 110/ChM wyd 5 z 01.09.2021
12 Cosmetics and household chemical products Chloride content Range: (0,05 -100,0)% NaCl Titrimetric method PB 95/ChM wyd 5 z 01.09.2021
13 Cosmetics and household chemical products Chloride content Range: (0,05 -100,0)% NaCl Potentiometric titration method
14 Cosmetics Count of mesophilic aerobic bacteria Plate method (pour plate) EN ISO 21149:2017-07 +A1:2023-01 z wyłączeniem punktu 9.3.2.2
15 Cosmetics Yeast and mould count Plate method (pour plate) PN-EN ISO 16212:2017-08 +A1:2023-01 z wyłączeniem punktu 9.3.2.2
16 Cosmetics Presence of Pseudomonas aeruginosa in 1 g (ml) of sample Culture method PN-EN ISO 22717:2016-01 +A1:2023-03
17 Cosmetics Presence of Staphylococcus aureus in 1 g (ml) of sample Culture method PN-EN ISO 22718:2016-01 +A1:2023-01
18 Cosmetics Presence of Escherichia coli in 1 g (ml) of sample Culture method PN-EN ISO 21150:2016-01 +A1:2023-03
19 Cosmetics Presence of Candida albicans in 1 g (ml) of sample Culture method PN-EN ISO 18416:2016-01 +A1:2023-03

Reference standards (17)

1/4
EN ISO 21149:2017-07 +A1:2023-01 z wyłączeniem punktu 9.3.2.2
PB 110/ChM wyd 5 z 01.09.2021
PB 95/ChM wyd 5 z 01.09.2021
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 14189:2016-10 z wyłączeniem punktu 8.2
PN-EN ISO 16212:2017-08 +A1:2023-01 z wyłączeniem punktu 9.3.2.2
PN-EN ISO 18416:2016-01 +A1:2023-03
PN-EN ISO 19458:2007
PN-EN ISO 21150:2016-01 +A1:2023-03
PN-EN ISO 22717:2016-01 +A1:2023-03
PN-EN ISO 22718:2016-01 +A1:2023-01
PN-EN ISO 6222:2004
PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014- 12 +A1:2017-04
PN-ISO 5667-5:2017-10 +Ap 1:2019-07