No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 30,0) ºC PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2 | PN-77/C-04584
2 Wastewater Sampling for chemical and physical testing Manual method Temperature of the wastewater sample taken Range: (5,0 – 30,0) ºC PN-ISO 5667-10:2021-11 PN-77/C-04584
3 Water Wastewater Rainwater and snowmelt water Mineral oil index Range: (0,5 – 25) mg/l Gas chromatography with flame ionisation detection (GC-FID) PN-EN ISO 9377-2:2003
4 Water Wastewater Rainwater and snowmelt water Total suspended solids (TSS) Range: (2,0 – 1000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
5 Water Wastewater Chemical oxygen demand - COD Range: (20 – 1000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
6 Water Wastewater Chemical oxygen demand - COD Range: (1000 – 10000) mg/l O 2 Spectrophotometric method I.32.4 wyd. 06 z dn. 22.05.2024 r. na podstawie testu Hach Lange nr LCK 014
7 Water Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 6000) mg/l O 2 Optical method PN-EN ISO 5815-1:2019-12
8 Water Wastewater Total phosphorus concentration Range: (0,02 – 50) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010
9 Water Wastewater Phenol index Range: (0,1 – 5) mg/l Spectrophotometric method PN-ISO 6439:1994
10 Water Wastewater Settleable solids Range: (1,0 – 100) ml/l Volumetric method PN-72/C-04559.03
11 Water Wastewater Kjeldahl nitrogen concentration Range: (5 – 150) mg/l Titrimetric method PN-EN 25663:2001
12 Water Wastewater Total nitrogen concentration (calculated) I.32.5 wyd. 02 z dn. 22.05.2024 r.
13 Water Wastewater Dissolved solids concentration Range: (100 – 20000) mg/l Gravimetric method PN-EN 15216:2010
14 Water Wastewater Concentration of substances extractable with petroleum ether Range: (0,5 – 100) mg/l Gravimetric method PN-86/C-04573.01
15 Water Wastewater Anionic surfactant concentration Range: (0,1 – 20) mg/l Spectrophotometric method PN-EN 903:2002
16 Water Wastewater Non-ionic surfactant concentration Range: (0,2 – 6) mg/l Spectrophotometric method I.32.7 wyd. 04 z dn. 22.05.2024 r. na podstawie testu Hach Lange nr LCK 333
17 Water Wastewater Manganese concentration Range: (0,02 – 5,0) mg/l Spectrophotometric method I.32.9 wyd. 03 z dn. 22.05.2024 r. na podstawie testu Hach Lange nr LCW 032
18 Water Wastewater Colour Range: (5 – 70) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015 Metoda C
19 Water Wastewater Ammonium nitrogen concentration Range: (2,0 – 150) mg/l Titrimetric method PN-ISO 5664:2002
20 Water Wastewater Nitrate nitrogen concentration Range: (0,04 – 20) mg/l Spectrophotometric method PN-82/C-04576.08
21 Water Wastewater Nitrite nitrogen concentration Range: (0,012 – 5,0) mg/l Spectrophotometric method PN-EN 26777:1999
22 Water Wastewater Chloride concentration Range: (10 – 1000) mg/l Titrimetric method PN-ISO 9297:1994
23 Water Wastewater Orthophosphate concentration Range: (0,04 – 50) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010
24 Water Wastewater pH Range: (2,0 – 12,0) Potentiometric method PN-EN ISO 10523:2012
25 Water Wastewater Electrical conductivity Range: (10 – 12880) µS/cm Conductometric method PN-EN 27888:1999
26 Water Wastewater Sulfate concentration Range: (10 – 500) mg/l Gravimetric method PN-ISO 9280:2002
27 Water Wastewater Total iron concentration Range: (0,02 – 5) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016
28 Water Wastewater Fluoride concentration Range: (0,05 – 20) mg/l Potentiometric method PN-78/C-04588.03
29 Water Wastewater Permanganate index Range: (1,0 – 50) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001
30 Water Wastewater Chromium (VI) concentration Range: (0,02 – 1,5) mg/l Spectrophotometric method PN-77/C-04604-08

Reference standards (31)

I.32.4 wyd. 06 z dn. 22.05.2024 r. na podstawie testu Hach Lange nr LCK 014
I.32.5 wyd. 02 z dn. 22.05.2024 r.
I.32.7 wyd. 04 z dn. 22.05.2024 r. na podstawie testu Hach Lange nr LCK 333
I.32.9 wyd. 03 z dn. 22.05.2024 r. na podstawie testu Hach Lange nr LCW 032
PN-72/C-04559.03
PN-77/C-04584
PN-77/C-04604-08
PN-78/C-04588.03
PN-82/C-04576.08
PN-86/C-04573.01
PN-EN 15216:2010
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7887:2012+Ap1:2015 Metoda C
PN-EN ISO 8467:2001
PN-EN ISO 9377-2:2003
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2
PN-ISO 6332:2001+Ap1:2016
PN-ISO 6439:1994
PN-ISO 9280:2002
PN-ISO 9297:1994