🇵🇱 KOPALNIA SOLI „KŁODAWA” S. A. PL
Environment
KOPALNIA SOLI „KŁODAWA” S. A. is a laboratory accredited by PCA under number AB 1463 (Kłodawa, Poland). Its accreditation scope covers 17 test methods in the following areas: Environment. Test objects include: Workplace environment – indoor electric lighting, Workplace environment - air, Test object/product, Workplace environment - noise.
At a glance
- Accreditation number: PCA AB 1463
- Methods in scope: 17
- Types of test objects: 6
- City: Kłodawa, Poland
- Accreditation number
- AB 1463
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAŃ ŚRODOWISKOWYCH, Al. 1000-lecia 2, 62-650 Kłodawa
- City
- Kłodawa, Poland
What this laboratory tests (6)
- Workplace environment – indoor electric lighting — 5 methods
- Workplace environment - air — 4 methods
- Test object/product — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment – hot microclimate — 2 methods
- Workplace environment – moderate microclimate — 2 methods
Accreditation scope — test methods (17)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - noise | A-weighted equivalent sound level A-weighted maximum sound level Range: (30,0 - 135,0) dB C-weighted peak sound level Range: (50,0 - 135,0) dB Direct measurement method | PN-N-01307:1994 PN-EN ISO 9612:2011 (z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11) | ||
| 2 | Workplace environment - noise | Noise exposure level normalised to: - an 8-hour working day (calculated) | |||
| 3 | Workplace environment - air | Sampling for occupational exposure assessment to: - dust agents inhalable fraction respirable fraction - inorganic substances respirable fraction Personal dosimetry method | PN-Z-04008-7/2002 PN-Z-04008-7/2002+Az1:2004 | ||
| 4 | Workplace environment - air | Exposure index (calculated) | |||
| 5 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction: - Wood dust - Coal dust - Dusts not classified according to toxicity Range: (0,14 – 34,0) mg/m3 Gravimetric method | PN-Z-04507:2022-05+Ap1:2022-08 | ||
| 6 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction: - Coal dust Range: (0,15 – 36.5) mg/m3 Gravimetric method | PN-Z-04508:2022-05+Ap1:2022-08 | ||
| 7 | Test object/product | Type of activity/ | |||
| 8 | Test object/product | characteristics tested/method | |||
| 9 | Workplace environment – indoor electric lighting | Illuminance | PN-83/E-04040.03 | ||
| 10 | Workplace environment – indoor electric lighting | Range: (0,5 – 9000) lx | IB-03 wydanie 7 z dnia 18.02.2025 | ||
| 11 | Workplace environment – indoor electric lighting | Direct measurement method | |||
| 12 | Workplace environment – indoor electric lighting | Illuminance uniformity | |||
| 13 | Workplace environment – indoor electric lighting | (calculated) | |||
| 14 | Workplace environment – hot microclimate | Air temperature Range: (10 - 50) °C Natural wet bulb temperature Range: (10 - 50) °C Blackened globe temperature Range: (10 - 50) °C Direct measurement method | PN-EN ISO 7243:2018-01 | ||
| 15 | Workplace environment – hot microclimate | WBGT index WBGT eff index (calculated) | |||
| 16 | Workplace environment – moderate microclimate | Air temperature Range: (10 - 40) °C Blackened globe temperature Range: (10 - 40) °C Air humidity Range: (20 - 75) % Air velocity Range: (0,15 - 5,0) m/s Direct measurement method | PN-EN ISO 7730:2006 | ||
| 17 | Workplace environment – moderate microclimate | PMV index PPD index (calculated) | |||
Reference standards (8)
IB-03 wydanie 7 z dnia 18.02.2025
PN-83/E-04040.03
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-N-01307:1994 PN-EN ISO 9612:2011 (z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11)
PN-Z-04008-7/2002 PN-Z-04008-7/2002+Az1:2004
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05+Ap1:2022-08