🇵🇱 MARCELI UCIŃSKI PRZEDSIĘBIORSTWO WIELOBRANŻOWE PL
Water & wastewater
MARCELI UCIŃSKI PRZEDSIĘBIORSTWO WIELOBRANŻOWE is a laboratory accredited by PCA under number AB 1462 (Koło, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater. Test objects include: Water Water intended for human consumption Wastewater, Water Wastewater, Soil, Wastewater Rainwater and snowmelt water.
At a glance
- Accreditation number: PCA AB 1462
- Methods in scope: 27
- Types of test objects: 7
- City: Koło, Poland
- Accreditation number
- AB 1462
- Accreditation body
- PCA
- Address
- „ELKOM”, LABORATORIUM ElkomLab, ul. PCK 10 a, 62-600 Koło
- City
- Koło, Poland
What this laboratory tests (7)
- Water Water intended for human consumption Wastewater — 13 methods
- Water Wastewater — 9 methods
- Soil — 1 method
- Wastewater Rainwater and snowmelt water — 1 method
- Water — 1 method
- Water intended for human consumption — 1 method
- Water Wastewater Rainwater and snowmelt water — 1 method
Accreditation scope — test methods (27)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water | Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 100,0) ºC | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 15 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.6 | PN-ISO 5667-11:2017-10 PN-77/C-04584 | ||
| 2 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 100,0) ºC | PN-ISO 5667-5:2017-10 PN-77/C-04584 | ||
| 3 | Wastewater Rainwater and snowmelt water | Sampling for chemical and physical testing Manual method Temperature of the wastewater sample taken Range: (0,0 – 100,0) ºC | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 4 | Water Water intended for human consumption Wastewater | Ammonium ion concentration Range: (0,05 – 350) mg/l Spectrophotometric method | B1, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14752.0001 | ||
| 5 | Water Water intended for human consumption Wastewater | Nitrate concentration Range: (2,5 – 1000) mg/l Spectrophotometric method | B3, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14773.0001 | ||
| 6 | Water Water intended for human consumption Wastewater | Nitrite concentration Range: (0,01 – 300) mg/l Spectrophotometric method | B4, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14776.0002 | ||
| 7 | Water Water intended for human consumption Wastewater | Manganese concentration Range: (0,02 – 200) mg/l Spectrophotometric method | B14, wyd. 1 z dn. 08.03.2017 r. na podstawie testu Merck nr 1.14770.0002 | ||
| 8 | Water Water intended for human consumption Wastewater | Iron concentration Range: (0,02 – 50) mg/l Spectrophotometric method | B12, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14761.0002 | ||
| 9 | Water Water intended for human consumption Wastewater | Colour Range: (5 – 100) mg/l Pt Visual method | PN-EN ISO 7887:2012 pkt. 7 | ||
| 10 | Water Water intended for human consumption Wastewater | Electrical conductivity Range: (100 – 100000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 11 | Water Water intended for human consumption Wastewater | pH Range: 2,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 12 | Water Water intended for human consumption Wastewater | Permanganate index Range: (1 – 1000) mg/l O 2 Titrimetric method | PN-EN ISO 8467:2001 | ||
| 13 | Water Water intended for human consumption Wastewater | Total calcium and magnesium content (total hardness) Range: (5,0 – 500) mg/l CaCO 3 (0,05 – 5,0) mmol/l Titrimetric method | PN-ISO 6059:1999 | ||
| 14 | Water Water intended for human consumption Wastewater | Chloride concentration Range: (5 – 1000) mg/l Spectrophotometric method | B5, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14897.0001 | ||
| 15 | Water Water intended for human consumption Wastewater | Calcium concentration Range: (2,0 – 200) mg/l (0,05 – 5,0) mmol/l Titrimetric method | PN-ISO 6058:1999 | ||
| 16 | Water Water intended for human consumption Wastewater | Magnesium concentration (calculated) | B13, wyd. 1 z dn. 15.04.2013 r. | ||
| 17 | Water Wastewater | Phosphate concentration Range: (0,05 – 1000) mg/l Spectrophotometric method | B6, wyd. 2 z dn. 06.05.2013 r. na podstawie testu Merck nr 1.14848.0001 | ||
| 18 | Water Wastewater | Total phosphorus concentration Range: (0,05 – 100) mg/l Spectrophotometric method | B6, wyd. 2 z dn. 06.05.2013 r. na podstawie testu Merck nr 1.14848.0001 | ||
| 19 | Water Wastewater | Total nitrogen concentration Range: (0,8 – 100) mg/l Spectrophotometric method | B2, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14537.0001 | ||
| 20 | Water Wastewater | Dissolved oxygen concentration Range: (0,50 – 10,0) mg/l O 2 Electrochemical method | PN-EN ISO 5814:2013-04 | ||
| 21 | Water Wastewater | Biochemical oxygen demand - BOD 5 Range: (3 – 4800) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 22 | Water Wastewater | Biochemical oxygen demand - BOD 5 Range: (0,50 – 6,0) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 23 | Water Wastewater | Chemical oxygen demand - COD Range: (7,0 – 1000) mg/l O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 24 | Water Wastewater | Dry residue, residue on ignition Range: (10 – 10000) mg/l Gravimetric method Loss on ignition (calculated) | PN-78/C-04541 | ||
| 25 | Water Wastewater | Dissolved solids, mineral dissolved solids Range: (10 – 10000) mg/l Gravimetric method Volatile dissolved solids (calculated) | |||
| 26 | Water Wastewater Rainwater and snowmelt water | Total suspended solids (TSS) Range: (5,0 – 2000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 27 | Soil | Sampling for chemical and physical testing | PN-R-04031:1997 | ||
Reference standards (26)
B1, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14752.0001
B12, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14761.0002
B13, wyd. 1 z dn. 15.04.2013 r.
B14, wyd. 1 z dn. 08.03.2017 r. na podstawie testu Merck nr 1.14770.0002
B2, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14537.0001
B3, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14773.0001
B4, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14776.0002
B5, wyd. 1 z dn. 04.04.2012 r. na podstawie testu Merck nr 1.14897.0001
B6, wyd. 2 z dn. 06.05.2013 r. na podstawie testu Merck nr 1.14848.0001
PN-78/C-04541
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7887:2012 pkt. 7
PN-EN ISO 8467:2001
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-11:2017-10 PN-77/C-04584
PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 15 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.6
PN-ISO 5667-5:2017-10 PN-77/C-04584
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-R-04031:1997