PCA AB 1453 • Pruszków, Poland • 4 methods

Other

SCILAB MEASUREMENTS ROBERT JASTRZĘBSKI is a laboratory accredited by PCA under number AB 1453 (Pruszków, Poland). Its accreditation scope covers 4 test methods in the following areas: Other. Test objects include: Equipment for measurement and control of industrial processes with…, Numerically controlled machine tools, machining centres.

At a glance

  • Accreditation number: PCA AB 1453
  • Methods in scope: 4
  • Types of test objects: 2
  • City: Pruszków, Poland
Accreditation number
AB 1453
Accreditation body
PCA
Address
ul. Zacisze 53/3, 05-800 Pruszków
City
Pruszków, Poland

What this laboratory tests (2)

Accreditation scope — test methods (4)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Equipment for measurement and control of industrial processes with linear displacement and force measuring systems Static transfer characteristics of the measuring chain and of the set physical quantities: - Inaccuracy - Non-repeatability - Hysteresis - Non-linearity of the chain (calculated) - Transfer coefficient (calculated) Measuring range: - Force (0,1 - 100) kN Strain gauge method Measuring range: - Displacement (0,1μm - 20 m) Laser interferometry method PN-EN 60770-1:2011 PN-EN 61298-2:2009 Instrukcja SL/I-03 wyd.2/3.2020
2 Equipment for measurement and control of industrial processes with linear displacement and force measuring systems Dynamic transfer characteristics of the measuring chain and of the set physical quantities: - force variations over time Measuring range (0,1 - 100) kN Strain gauge method - displacements over time Measuring ranges: - Displacement (0,1 μm - 20 m), - Velocity up to 4 m/s - Time (of motion, signal response, accele- ration, braking, reversal, rise, motion cycle duration) (0,1 ms - 8 h) - Rotational speed (calculated) - Acceleration (calculated) Laser interferometry method Instrukcja SL/I-03 wyd.2/3.2020 PN-EN 60770-1:2011
3 Numerically controlled machine tools, machining centres Straightness and angular deviations of moving axes Measuring ranges: - Angular deviations (0,001 - 5)º over a length up to 20 m, - Straightness (0,1 μm - 4 mm) over a length up to 4 m Laser interferometry method ISO 230-1:2012 pkt 8.2.2.5 pkt 8.2.3 pkt 8.4.2.3 pkt 12.1.3.4
4 Numerically controlled machine tools, machining centres Accuracy and repeatability of position- ing of numerically controlled linear axes Measuring range: (0,1 µm - 20 m) Laser interferometry method ISO 230-2:2014 PN-ISO10791-4:2001

Reference standards (4)

ISO 230-1:2012 pkt 8.2.2.5 pkt 8.2.3 pkt 8.4.2.3 pkt 12.1.3.4
ISO 230-2:2014 PN-ISO10791-4:2001
Instrukcja SL/I-03 wyd.2/3.2020 PN-EN 60770-1:2011
PN-EN 60770-1:2011 PN-EN 61298-2:2009 Instrukcja SL/I-03 wyd.2/3.2020