🇵🇱 TARNOBRZESKIE WODOCIĄGI Sp. z o.o. PL
Water & wastewaterMicrobiology
TARNOBRZESKIE WODOCIĄGI Sp. z o.o. is a laboratory accredited by PCA under number AB 1452 (Tarnobrzeg, Poland). Its accreditation scope covers 31 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, water, Wastewater, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.
At a glance
- Accreditation number: PCA AB 1452
- Methods in scope: 31
- Types of test objects: 3
- Techniques used: 12
- City: Tarnobrzeg, Poland
- Accreditation number
- AB 1452
- Accreditation body
- PCA
- Address
- ul. Wiślna 1, 39-400 Tarnobrzeg, LABORATORIUM WODY I ŚCIEKÓW, Stale, ul. prof. Pawłowskiego 33, 39-400 Tarnobrzeg
- City
- Tarnobrzeg, Poland
What this laboratory tests (3)
- Water intended for human consumption, water — 17 methods
- Wastewater — 13 methods
- Water intended for human consumption — 1 method
Analytical techniques used (12)
- Spectrophotometric method — 8 methods
- Titrimetric method — 4 methods
- Membrane filtration method — 3 methods
- Electrochemical method — 2 methods
- MPN method — 2 methods
- Plate method (pour plate) — 2 methods
- Potentiometric method — 2 methods
- Conductometric method — 1 method
- Gravimetric method — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
- Visual method — 1 method
Laboratory sections (2)
- Water Testing Laboratory; Stale, ul. prof. Pawłowskiego 33, 39-400 Tarnobrzeg — 18 methods
- Wastewater Testing Laboratory — 13 methods
Laboratory locations
- LABORATORIUM WODY I ŚCIEKÓW — Stale, ul. prof. Pawłowskiego 33
- Pracownia Badania Wody — Stale, ul. prof. Pawłowskiego 33, 39-400 Tarnobrzeg
- Pracownia Badania Ścieków — ul. Podwale 3, 39-400 Tarnobrzeg
- Pracownia Badania Wody; Stale, ul. prof. Pawłowskiego 33, 39-400 Tarnobrzeg —
Accreditation scope — test methods (31)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Water Testing Laboratory; Stale, ul. prof. Pawłowskiego 33, 39-400 Tarnobrzeg | |||||
| 1 | Water intended for human consumption, water | pH Range 2,0 − 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 2 | Water intended for human consumption, water | Electrical conductivity Range (84 − 12900) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 3 | Water intended for human consumption, water | Colour Range (5 − 140) mg/l Pt |
Visual method | PN-EN ISO 7887:2012, Metoda D +Ap1:2015-06 | |
| 4 | Water intended for human consumption, water | Turbidity Range (0,25 − 70) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 5 | Water intended for human consumption, water | Manganese concentration Range (0,010 − 5,00) mg/l |
Spectrophotometric method | PN-92/C-04590/02 | |
| 6 | Water intended for human consumption, water | Total iron concentration Range (0,020 − 5,00) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 7 | Water intended for human consumption, water | Chloride concentration Range (5,0 − 250) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 8 | Water intended for human consumption, water | Total hardness (total calcium and magnesium concentration) Range (0,05 − 5,0) mmol/l |
Titrimetric method | PN-ISO 6059:1999 | |
| 9 | Water intended for human consumption, water | Free chlorine concentration Range (0,05 − 2,0) mg/l |
Spectrophotometric method | PB/W/06 wydanie II z 29.12.2025 | |
| 10 | Water intended for human consumption | Sampling for chemical and physical testing Temperature Range (0,0 − 25,0) oC |
PN-ISO 5667-5:2017-10 | PN-77/C-04584 | ||
| 11 | Water intended for human consumption, water | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 12 | Water intended for human consumption, water | Most probable number, Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 13 | Water intended for human consumption, water | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 14 | Water intended for human consumption, water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 15 | Water intended for human consumption, water | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 16 | Water intended for human consumption, water | Total viable count at 36oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 17 | Water intended for human consumption, water | Total viable count at 22oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 18 | Water intended for human consumption, water | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wył. pkt 4.4.3; 4.4.4; 4.4.5; 4.4.6, | ||
| Wastewater Testing Laboratory | |||||
| 19 | Wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 20 | Wastewater | Ammonium nitrogen concentration Range (0,1 – 100) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 21 | Wastewater | Ammonium nitrogen concentration Range (3,00 – 1000) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 22 | Wastewater | Nitrite nitrogen concentration Range (0,010 – 20) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 23 | Wastewater | Nitrate nitrogen concentration Range (0,05 – 50) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 24 | Wastewater | Total phosphorus concentration Range (0,040 – 100) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p. 7 + Ap1:2010 + Ap2:2010 | |
| 25 | Wastewater | Chemical oxygen demand COD-Cr Range (8,0 – 2000) mg/l O2 |
Spectrophotometric method | P N - ISO 15705:2005 | |
| 26 | Wastewater | Biochemical oxygen demand – BOD5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 27 | Wastewater | Biochemical oxygen demand – BOD5 Range (1 – 3000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 28 | Wastewater | Kjeldahl nitrogen concentration Range (1,00– 500) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 29 | Wastewater | Total suspended solids (TSS) Range (2,0 – 2000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 30 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576.14 | ||
| 31 | Wastewater | Sampling for chemical and physical testing Temperature Range (0,0 − 50,0) oC |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
Reference standards (28)
P N - ISO 15705:2005
PB/W/06 wydanie II z 29.12.2025
PN-73/C-04576.14
PN-77/C-04584
PN-82/C-04576/08
PN-92/C-04590/02
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wył. pkt 4.4.3; 4.4.4; 4.4.5; 4.4.6,
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p. 7 + Ap1:2010 + Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012, Metoda D +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994