🇵🇱 KATOWICKIE WODOCIĄGI S.A. PL

PCA AB 1433 • Katowice, Poland • 90 methods

Water & wastewaterMicrobiologyMaterials & polymers

KATOWICKIE WODOCIĄGI S.A. is a laboratory accredited by PCA under number AB 1433 (Katowice, Poland). Its accreditation scope covers 90 test methods in the following areas: Water & wastewater, Microbiology, Materials & polymers. Test objects include: Water, Swimming pool water, Wastewater, Water, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 1433
  • Methods in scope: 90
  • Types of test objects: 8
  • Techniques used: 18
  • City: Katowice, Poland
Accreditation number
AB 1433
Accreditation body
PCA
Address
ul. Obrońców Westerplatte 89, 40-335 Katowice, LABORATORIUM CENTRALNE
City
Katowice, Poland

What this laboratory tests (8)

Analytical techniques used (18)

Laboratory sections (3)

Laboratory locations

Certificate information

Issue date
18.05.2026
Issue no.
16

Accreditation scope — test methods (90)

No. Test object Methodology / Parameters Technique Reference document
Microbiology Laboratory
1 Water Sampling for microbiological testing PN-EN ISO 19458:2007
2 Water Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
3 Water Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
4 Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
5 Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
6 Water Count of faecal streptococci (enterococci) Membrane filtration method PN-EN ISO 7899-2:2004
7 Water Most probable number of coliform bacteria Metoda NPL (Test Colilert) PN-EN ISO 9308-2:2014-06
8 Water Most probable number of Escherichia coli Metoda NPL (Test Colilert) PN-EN ISO 9308-2:2014-06
9 Water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
10 Water Liczba bakterii z rodzaju Legionella, Matryca: A, Procedura: 1 (pożywka A, B) Plate method (spread plate) PN-EN ISO 11731:2017-08 +Ap1:2019-12
11 Water Liczba bakterii z rodzaju Legionella, Matryca: A, Procedura: 5 (pożywka A, B), Procedura: 7 (pożywka B, C) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
12 Water Liczba bakterii z rodzaju Legionella, Matryca: B, Procedura: 7 (pożywka B, C) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
13 Water Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000
14 Water Clostridium perfringens count Membrane filtration method PN-EN ISO 14189:2016-10
15 Swimming pool water Sampling for microbiological testing PN-EN ISO 19458:2007
16 Swimming pool water Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
17 Swimming pool water Escherichia coli count Metoda NPL (Test Colilert) PN-EN ISO 9308-2:2014-06
18 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
19 Swimming pool water Liczba bakterii z rodzaju Legionella, Matryca: B, Procedura: 7 (pożywka B, C) Membrane filtration method PN-EN ISO 11731:2017-08+Ap1:2019-12
20 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000
21 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
Pracownia Wody
22 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
23 Water intended for human consumption Temperature
Range (0,5 – 50,0) °C
PN-77/C-04584
24 Swimming pool water Sampling for chemical and physical testing IO-5.7.4 Wydanie 3 z dnia 10.12.2024
25 Swimming pool water Temperature
Range (0,5 – 50,0) °C
PN-77/C-04584
26 Water Sampling for chemical and physical testing Manual method PN-EN ISO 5667-6:2016-12 +A11:2020-10 z wyłączeniem pkt. 7.5, pkt. 7.6 oraz pkt. 8.2
27 Water Temperature
Range (0,5 – 35,0) °C
PN-77/C-04584
28 Water, Water intended for human consumption pH
Range (4,0 – 10,0)
Potentiometric method PN-EN ISO 10523:2012
29 Water, Water intended for human consumption Turbidity
Range (0,10 – 400) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
30 Water, Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 +Ap1:2015-06, metoda D
31 Water, Water intended for human consumption Electrical conductivity
Range (10 – 2500) μS/cm
Conductometric method PN-EN 27888:1999
32 Water, Water intended for human consumption Free chlorine concentration ☑
Range (0,05 – 1,64) mg/l
Regulated area: ☑ - badania wykonywane poza siedzibą Laboratorium
Spectrophotometric method PB-05 Wydanie 4 z dnia 10.12.2024
33 Water, Water intended for human consumption Total iron concentration
Range (30 – 3500) μg/l
Spectrophotometric method PN-ISO 6332:2001 +Ap1:2016-06
34 Water, Water intended for human consumption Chloride concentration
Range (5,0 – 800) mg/l
Titrimetric method PN-ISO 9297:1994
35 Water, Water intended for human consumption Ammonia (ammonium ion) concentration
Range (0,050 – 5,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
36 Water, Water intended for human consumption Nitrite concentration
Range (0,050 – 0,50) mg/l
Spectrophotometric method PN-EN 26777:1999
37 Water, Water intended for human consumption Nitrate concentration
Range (1,0 – 60) mg/l
Spectrophotometric method PN-82/C-04576/08
38 Water, Water intended for human consumption Total calcium and magnesium content (Total hardness)
Range (10 – 1250) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
39 Water, Water intended for human consumption Calcium concentration
Range (2,0 – 250) mg/l
Titrimetric method PN-ISO 6058:1999
40 Water, Water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 załącznik A
41 Water, Water intended for human consumption Metal concentrations
Manganese (5,0 – 3000) μg/l Cadmium (0,5 – 110) μg/l Copper (3,0 – 2500) μg/l Nickel (5,0 – 1000) μg/l Total chromium (2,0 – 500) μg/l Arsenic (3,0 – 100) μg/l Lead (3,0 – 250) μg/l Silver (0,0010 – 0,50) mg/l Iron (25 – 20000) μg/l Aluminium (15 – 500) μg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
42 Water, Water intended for human consumption Permanganate index
Range (0,50 – 15) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
43 Water, Water intended for human consumption Trihalomethane (THM) concentration:
trichloromethane (chloroform) Range (1,0 – 100) μg/l bromodichloromethane (1,0 – 100) μg/l dibromochloromethane (1,0 – 100) μg/l tribromomethane (bromoform) (1,0 – 100) μg/l
Headspace gas chromatography with electron capture detection (HS-GC-ECD) PN-EN ISO 10301:2002
44 Water, Water intended for human consumption Ʃ THM (calculated) PN-EN ISO 10301:2002
45 Water, Water intended for human consumption Oxidation-reduction potential ☑ (redox) ref. to Ag/AgCl 3,5 mol/l KCl
Range (200 – 800) mV
Regulated area: ☑ - badania wykonywane poza siedzibą Laboratorium
Potentiometric method PB-27 Wydanie 2 z dnia 10.12.2024
46 Woda, Wody opadowe, Wody roztopowe, Ścieki Mineral oil index
Range (0,5 – 50) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
47 Swimming pool water Turbidity
Range (0,10 – 400) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
48 Swimming pool water Nitrate concentration
Range (1,0 – 60) mg/l
Spectrophotometric method PN-82/C-04576/08
49 Swimming pool water pH +☑
Range (4,0 – 10,0)
Regulated area: +☑ - badania wykonywane w siedzibie i poza siedzibą Laboratorium
Potentiometric method PN-EN ISO 10523:2012
50 Swimming pool water Permanganate index
Range (0,50 – 15) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
51 Swimming pool water Free chlorine concentration ☑
Range (0,05 – 1,64) mg/l
Regulated area: ☑ - badania wykonywane poza siedzibą Laboratorium
Spectrophotometric method PB-05 Wydanie 4 z dnia 10.12.2024
52 Swimming pool water Stężenie chloru całkowitego ☑
Range (0,05 – 2,0) mg/l
Regulated area: ☑ - badania wykonywane poza siedzibą Laboratorium
Spectrophotometric method PB-26 Wydanie 2 z dnia 10.12.2024
53 Swimming pool water Combined chlorine (calculated) PB-26 Wydanie 2 z dnia 10.12.2024
54 Swimming pool water Oxidation-reduction potential ☑ (redox) ref. to Ag/AgCl 3,5 mol/l KCl
Range (200-800) mV
Regulated area: ☑ - badania wykonywane poza siedzibą Laboratorium
Potentiometric method PB-27 Wydanie 2 z dnia 10.12.2024
55 Swimming pool water Trihalomethane (THM) concentration:
trichloromethane (chloroform) Range (1,0 – 100) μg/l bromodichloromethane (1,0 – 100) μg/l dibromochloromethane (1,0 – 100) μg/l tribromomethane (bromoform) (1,0 – 100) μg/l
Headspace gas chromatography with electron capture detection (HS-GC-ECD) PN-EN ISO 10301:2002
56 Swimming pool water Ʃ THM (calculated) PN-EN ISO 10301:2002
57 Swimming pool water Metal concentrations
Aluminium (15 – 500) μg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
Wastewater Laboratory
58 Wastewater Sampling for physical and chemical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
59 Wastewater Temperature
Range (0,5 – 50,0) °C
PN-77/C-04584
60 Wastewater pH
Range (4,0 – 10,0)
Potentiometric method PN-EN ISO 10523:2012
61 Wastewater Chloride concentration
Range (5,0 – 20 000) mg/l
Titrimetric method PN-ISO 9297:1994
62 Wastewater Nitrate nitrogen concentration
Range (0,090 – 50) mg/l
Spectrophotometric method PN-82/C-04576.08
63 Wastewater Nitrite nitrogen concentration
Range (0,015 – 5,0) mg/l
Spectrophotometric method PN-EN 26777:1999
64 Wastewater Chemiczne zapotrzebowanie tlenu -ChZT
Range (15 – 6000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
65 Wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
66 Wastewater Biochemical oxygen demand
BOD5 Range (1 – 2000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
67 Wastewater Total suspended solids (TSS)
Range (2,0 – 3000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
68 Wastewater Total phosphorus concentration
Range (0,050 – 50,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010, pkt.8
69 Wastewater Ammonium nitrogen concentration
Range (0,50 – 1000) mg/l
Titrimetric method PN-ISO 5664:2002
70 Wastewater Orthophosphate concentration
Range (0,04 – 40) mg/l P
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010, pkt.4
71 Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
72 Wastewater Kjeldahl nitrogen concentration
Range (1,0 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
73 Wastewater Sulfate concentration
Range (10 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
74 Wastewater Chemical oxygen demand
COD Range (30 – 3000) mg/l O2
Titrimetric method PN-ISO 6060:2006
75 Wastewater Metal concentrations:
Copper (0,050 – 6) mg/l Zinc (0,050 – 10) mg/l Cadmium (0,020 – 2) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Metoda A
76 Wastewater Metal concentrations:
Lead (0,006 – 1,5) mg/l Arsenic (0,010 – 1,0) mg/l Total chromium (0,002 – 5,0) mg/l Silver (0,001 – 0,5) mg/l Vanadium (0,020 – 4,0) mg/l Nickel (0,005 – 5,0) mg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
77 Sewage sludge Metal concentrations:
Nickel (25 – 1000) mg/kg Copper (50 – 4000) mg/kg Zinc (5,0 – 7000) mg/kg Cadmium (2,0 – 100) mg/kg Lead (25 – 3000) mg/kg
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Metoda A
78 Sewage sludge Stężenie chromu ogólnego:
Range (40 – 3000) mg/kg
Flame atomic absorption spectrometry (FAAS) PB-28 Wydanie 2 z dnia 10.12.2024
79 Sewage sludge Dry residue / water content
Range (10 – 96)%
Gravimetric method PN-EN 12880:2004
80 Sewage sludge Kjeldahl nitrogen concentration
Range (3,80 – 7,00) %
Titrimetric method PN-EN 13342:2002
81 Sewage sludge Total phosphorus concentration
Range (1,00 – 4,00) %
Spectrophotometric method PN-EN 14672:2006
82 Rainwater, Snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
83 Rainwater, Snowmelt water Temperature
Range (0,5 – 35,0) °C
PN-77/C-04584
84 Rainwater, Snowmelt water Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
85 Water Chemical oxygen demand
COD Range (15 – 3000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
86 Water Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
87 Water Kjeldahl nitrogen concentration
Range (1,0 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
88 Water Orthophosphate concentration
Range (0,04 – 40) mg/l P
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010, pkt.4
89 Water Total nitrogen concentration (calculated) PN-73/C-04576/14
90 Water Total phosphorus concentration
Range (0,05 – 50,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010, pkt.8

Reference standards (51)

IO-5.7.4 Wydanie 3 z dnia 10.12.2024
PB-05 Wydanie 4 z dnia 10.12.2024
PB-26 Wydanie 2 z dnia 10.12.2024
PB-27 Wydanie 2 z dnia 10.12.2024
PB-28 Wydanie 2 z dnia 10.12.2024
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576.08
PN-82/C-04576/08
PN-C-04554-4:1999 załącznik A
PN-EN 12880:2004
PN-EN 13342:2002
PN-EN 14672:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10301:2002
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 11731:2017-08+Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 15586:2005
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5667-6:2016-12 +A11:2020-10 z wyłączeniem pkt. 7.5, pkt. 7.6 oraz pkt. 8.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010, pkt.4
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010, pkt.8
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 +Ap1:2015-06, metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9377-2:2003
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001 +Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 8288:2002 Metoda A
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-Z-11001-3:2000

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201433