🇵🇱 ZAKŁAD USŁUG GEOLOGICZNYCH GEOTECH Sp. z o.o. PL

PCA AB 1416 • Rzeszów, Poland • 20 methods

Other

ZAKŁAD USŁUG GEOLOGICZNYCH GEOTECH Sp. z o.o. is a laboratory accredited by PCA under number AB 1416 (Rzeszów, Poland). Its accreditation scope covers 20 test methods in the following areas: Other. Test objects include: Ground, Natural stone.

At a glance

  • Accreditation number: PCA AB 1416
  • Methods in scope: 20
  • Types of test objects: 2
  • City: Rzeszów, Poland
Accreditation number
AB 1416
Accreditation body
PCA
Address
LABORATORIUM MECHANIKI GRUNTÓW I SKAŁ, ul. Budziwojska 79, 35-317 Rzeszów
City
Rzeszów, Poland

What this laboratory tests (2)

Accreditation scope — test methods (20)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Ground Macroscopic analysis PN-EN ISO 14688-1:2018-05 PN-88/B-04481 p. 3
2 Ground Humidity PN-88/B-04481 PN-EN ISO 17892-1:2015-02
3 Ground Sieve analysis PN-88/B-04481 p. 4.1
4 Ground Hydrometer analysis PN-88/B-04481 p. 4.2
5 Ground Yield strength PN-88/B-04481 p. 5.5 PKN-CEN ISO/TS 17892-12:2009 PN-EN ISO 17892-12:2018-08
6 Ground Liquid limit Cone penetrometer method PKN-CEN | ISO/TS 17892-12:2009 PN-EN ISO 17892-12:2018-08
7 Ground Organic matter content Ignition method PN-88/B-04481 p. 4.4
8 Ground Organic matter content Oxidation method
9 Ground Bulk density PN-88/B-04481 p. 5.2.6 PN-EN ISO 17892-2:2015-02 p. 5.1
10 Ground Compressibility modulus determined in an oedometer PN-88/B-04481 p. 6.1
11 Ground Permeability at constant and variable hydraulic gradient PKN-CEN | ISO/TS 17892-11:2009 p. 4.2
12 Ground Optimum moisture content and maximum dry density of the soil skeleton PN-88/B-04481 p. 8
13 Ground Sand equivalent value PN-EN 933-8+A1:2015-07
14 Ground Particle size distribution Range: (0,063 - 63) mm PN-EN ISO 17892-4:2017 pkt. 5.2
15 Ground Direct shear apparatus test - shear box apparatus PN-EN ISO 17892-10:2019-01E
16 Ground Testing of soils in a triaxial compression apparatus after water saturation Cell pressure range: (0 - 3500) kPa PN-EN ISO 17892-9:2018-05
17 Ground Testing of soils in a triaxial compression apparatus without water saturation and without consolidation Cell pressure range: (0 - 3500) kPa PN-EN ISO 17892-8:2018-05
18 Natural stone Uniaxial compressive strength Force range: (1 – 1000) kN PN-EN 1926:2007
19 Natural stone Tensile strength by the transverse compression method Force range: (1 – 100) kN PN-G-04302:1997
20 Natural stone Compressive strength Force range: (1 – 2000) kN PN-G-04303:1997

Reference standards (20)

ISO/TS 17892-11:2009 p. 4.2
ISO/TS 17892-12:2009 PN-EN ISO 17892-12:2018-08
PKN-CEN
PN-88/B-04481 PN-EN ISO 17892-1:2015-02
PN-88/B-04481 p. 4.1
PN-88/B-04481 p. 4.2
PN-88/B-04481 p. 4.4
PN-88/B-04481 p. 5.2.6 PN-EN ISO 17892-2:2015-02 p. 5.1
PN-88/B-04481 p. 5.5 PKN-CEN ISO/TS 17892-12:2009 PN-EN ISO 17892-12:2018-08
PN-88/B-04481 p. 6.1
PN-88/B-04481 p. 8
PN-EN 1926:2007
PN-EN 933-8+A1:2015-07
PN-EN ISO 14688-1:2018-05 PN-88/B-04481 p. 3
PN-EN ISO 17892-10:2019-01E
PN-EN ISO 17892-4:2017 pkt. 5.2
PN-EN ISO 17892-8:2018-05
PN-EN ISO 17892-9:2018-05
PN-G-04302:1997
PN-G-04303:1997