🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW PL
Water & wastewaterMicrobiology
MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW is a laboratory accredited by PCA under number AB 1386 (Włocławek, Poland). Its accreditation scope covers 37 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Wastewater, Water intended for human consumption, Sewage sludge.
At a glance
- Accreditation number: PCA AB 1386
- Methods in scope: 37
- Types of test objects: 5
- City: Włocławek, Poland
- Accreditation number
- AB 1386
- Accreditation body
- PCA
- Address
- I KANALIZACJI Sp. z o.o., ul. Toruńska 146, 87-800 Włocławek
- City
- Włocławek, Poland
What this laboratory tests (5)
- Water — 13 methods
- Wastewater — 12 methods
- Water intended for human consumption — 7 methods
- Sewage sludge — 3 methods
- Water, wastewater — 2 methods
Accreditation scope — test methods (37)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 2 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 3 | Water | Total iron concentration Range: (0,040 – 10,00) mg/l Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | ||
| 4 | Water | Manganese concentration Range: (0,015 – 4,00) mg/l Spectrophotometric method | PN-92/C-04590/03 | ||
| 5 | Water | Nitrate concentration Range: (0,18 – 4,43) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 6 | Water | Nitrite concentration Range: (0,020 – 0,82) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 7 | Water | Colour Range: (5 – 70) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 p.6 +Ap1:2015-06 | ||
| 8 | Water | Turbidity Range: (0,30 – 40) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 9 | Water | Electrical conductivity Range: (100 – 2500) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 10 | Water | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 11 | Water | Chloride concentration Range: (5 – 1000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 12 | Water | Sulphate concentration Range: (10 – 1000) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
| 13 | Water | Ammonium ion concentration Range: (0,060 – 1,29) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 14 | Water | Total suspended solids (TSS) Range: (2,0 – 500) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 15 | Water | Total calcium and magnesium content (total hardness) Range: (5 – 1000) mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 16 | Water intended for human consumption | Total count of microorganisms at 22 C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 17 | Water intended for human consumption | Total count of microorganisms at 36 C Plate method (pour plate) | |||
| 18 | Water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12 + A1:2017-04 | ||
| 19 | Water intended for human consumption | Escherichia coli count Membrane filtration method | |||
| 20 | Water intended for human consumption | Intestinal enterococci count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 21 | Water, wastewater | Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 22 | Water, wastewater | Chemical oxygen demand - COD-Cr Range: (4 – 10000) mg/l O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 23 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method Measurement of the temperature of wastewater/ of the wastewater sample taken Range: (4,0 – 35,0) ºC | PN-ISO 5667-10:2021-11 PB-03/W,Ś wydanie 2 z dnia 10.05.2019 r. | ||
| 24 | Wastewater | pH Range: 3,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 25 | Wastewater | Biochemical oxygen demand - BOD 5 Range: (3 – 3000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 26 | Wastewater | Total suspended solids (TSS) Range: (2,0 – 3000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 27 | Wastewater | Nitrate nitrogen concentration Range: (0,14 – 30) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 28 | Wastewater | Nitrite nitrogen concentration Range: (0,02 – 1,0) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 29 | Wastewater | Kjeldahl nitrogen concentration Range: (2,0 – 1000) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 30 | Wastewater | Total nitrogen concentration (calculated) | PB-02/Ś wydanie 3 z dnia 15.10.2019 r. | ||
| 31 | Wastewater | Total phosphorus concentration Range: (0,080 – 30,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 rozdział 8 +Ap1:2010+Ap2:2010 | ||
| 32 | Wastewater | Chloride concentration Range: (5 – 2000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 33 | Wastewater | Dissolved sulphate concentration Range: (10 – 1000) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
| 34 | Wastewater | Ammonium nitrogen concentration Range: (1,0 – 1000) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 35 | Sewage sludge | pH - in H O 2 Range: 3,0 – 12,0 Potentiometric method | PN-EN ISO 10390:2022-09 | ||
| 36 | Sewage sludge | Loss on ignition of dry matter - organic matter Range: (0,2 – 99,8) % Gravimetric method | PN-EN 12879:2004 | ||
| 37 | Sewage sludge | Dry residue and water content Range: (0,5 – 99,5) % Gravimetric method | PN-EN 12880:2004 | ||
Reference standards (29)
PB-02/Ś wydanie 3 z dnia 15.10.2019 r.
PN-82/C-04576.08
PN-92/C-04590/03
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 rozdział 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p.6 +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12 + A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PB-03/W,Ś wydanie 2 z dnia 10.05.2019 r.
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994