🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW PL

PCA AB 1386 • Włocławek, Poland • 37 methods

Water & wastewaterMicrobiology

MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW is a laboratory accredited by PCA under number AB 1386 (Włocławek, Poland). Its accreditation scope covers 37 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Wastewater, Water intended for human consumption, Sewage sludge.

At a glance

  • Accreditation number: PCA AB 1386
  • Methods in scope: 37
  • Types of test objects: 5
  • City: Włocławek, Poland
Accreditation number
AB 1386
Accreditation body
PCA
Address
I KANALIZACJI Sp. z o.o., ul. Toruńska 146, 87-800 Włocławek
City
Włocławek, Poland

What this laboratory tests (5)

Accreditation scope — test methods (37)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
2 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
3 Water Total iron concentration Range: (0,040 – 10,00) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
4 Water Manganese concentration Range: (0,015 – 4,00) mg/l Spectrophotometric method PN-92/C-04590/03
5 Water Nitrate concentration Range: (0,18 – 4,43) mg/l Spectrophotometric method PN-82/C-04576.08
6 Water Nitrite concentration Range: (0,020 – 0,82) mg/l Spectrophotometric method PN-EN 26777:1999
7 Water Colour Range: (5 – 70) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 p.6 +Ap1:2015-06
8 Water Turbidity Range: (0,30 – 40) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
9 Water Electrical conductivity Range: (100 – 2500) µS/cm Conductometric method PN-EN 27888:1999
10 Water pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
11 Water Chloride concentration Range: (5 – 1000) mg/l Titrimetric method PN-ISO 9297:1994
12 Water Sulphate concentration Range: (10 – 1000) mg/l Gravimetric method PN-ISO 9280:2002
13 Water Ammonium ion concentration Range: (0,060 – 1,29) mg/l Spectrophotometric method PN-ISO 7150-1:2002
14 Water Total suspended solids (TSS) Range: (2,0 – 500) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
15 Water Total calcium and magnesium content (total hardness) Range: (5 – 1000) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
16 Water intended for human consumption Total count of microorganisms at 22 C Plate method (pour plate) PN-EN ISO 6222:2004
17 Water intended for human consumption Total count of microorganisms at 36 C Plate method (pour plate)
18 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12 + A1:2017-04
19 Water intended for human consumption Escherichia coli count Membrane filtration method
20 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
21 Water, wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
22 Water, wastewater Chemical oxygen demand - COD-Cr Range: (4 – 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
23 Wastewater Sampling for chemical and physical testing Manual method Automatic method Measurement of the temperature of wastewater/ of the wastewater sample taken Range: (4,0 – 35,0) ºC PN-ISO 5667-10:2021-11 PB-03/W,Ś wydanie 2 z dnia 10.05.2019 r.
24 Wastewater pH Range: 3,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012
25 Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 3000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
26 Wastewater Total suspended solids (TSS) Range: (2,0 – 3000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
27 Wastewater Nitrate nitrogen concentration Range: (0,14 – 30) mg/l Spectrophotometric method PN-82/C-04576.08
28 Wastewater Nitrite nitrogen concentration Range: (0,02 – 1,0) mg/l Spectrophotometric method PN-EN 26777:1999
29 Wastewater Kjeldahl nitrogen concentration Range: (2,0 – 1000) mg/l Titrimetric method PN-EN 25663:2001
30 Wastewater Total nitrogen concentration (calculated) PB-02/Ś wydanie 3 z dnia 15.10.2019 r.
31 Wastewater Total phosphorus concentration Range: (0,080 – 30,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 rozdział 8 +Ap1:2010+Ap2:2010
32 Wastewater Chloride concentration Range: (5 – 2000) mg/l Titrimetric method PN-ISO 9297:1994
33 Wastewater Dissolved sulphate concentration Range: (10 – 1000) mg/l Gravimetric method PN-ISO 9280:2002
34 Wastewater Ammonium nitrogen concentration Range: (1,0 – 1000) mg/l Titrimetric method PN-ISO 5664:2002
35 Sewage sludge pH - in H O 2 Range: 3,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09
36 Sewage sludge Loss on ignition of dry matter - organic matter Range: (0,2 – 99,8) % Gravimetric method PN-EN 12879:2004
37 Sewage sludge Dry residue and water content Range: (0,5 – 99,5) % Gravimetric method PN-EN 12880:2004

Reference standards (29)

PB-02/Ś wydanie 3 z dnia 15.10.2019 r.
PN-82/C-04576.08
PN-92/C-04590/03
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 rozdział 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p.6 +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12 + A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PB-03/W,Ś wydanie 2 z dnia 10.05.2019 r.
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994