🇵🇱 PRZEDSIĘBIORSTWO ROBÓT TELEKOMUNIKACYJNYCH BAZA PL
EnvironmentElectronics & EMC
PRZEDSIĘBIORSTWO ROBÓT TELEKOMUNIKACYJNYCH BAZA is a laboratory accredited by PCA under number AB 1361 (Toruń, Poland). Its accreditation scope covers 6 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment – electromagnetic field in the workspace duri…. Most frequently used techniques: Direct measurement method.
At a glance
- Accreditation number: PCA AB 1361
- Methods in scope: 6
- Types of test objects: 2
- Techniques used: 1
- City: Toruń, Poland
- Accreditation number
- AB 1361
- Accreditation body
- PCA
- Address
- SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ, ul. Henryka Strobanda 23, 87-100 Toruń
- City
- Toruń, Poland
What this laboratory tests (2)
- Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) — 3 methods
- Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) — 3 methods
Analytical techniques used (1)
- Direct measurement method — 4 methods
Laboratory locations
- LABORATORIUM BADAWCZE — ul. Forteczna 13b
Accreditation scope — test methods (6)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| LABORATORIUM BADAWCZE | |||||
| 1 | Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) | Electric field strength: in the frequency range Od 100 MHz do 90 GHz Range (0,8 – 300) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 2 | Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) | Magnetic field strength: in the frequency range od 27 MHz do 1 GHz Range (0,012 – 1,0) A/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 3 | Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) | Magnetic field strength: in the frequency range od 800 MHz do 90 GHz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | ||
| 4 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Electric field strength: in the frequency range od 100 MHz do 90 GHz Range (0,6 – 300) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630) | |
| 5 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: in the frequency range od 27 MHz do 1 GHz Range (0,012 – 1,0) A/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630) | |
| 6 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: in the frequency range od 100 MHz do 90 GHz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
Reference standards (3)
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)