🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 1353 • Oświęcim, Poland • 24 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1353 (Oświęcim, Poland). Its accreditation scope covers 24 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, water, Water intended for human consumption, Water, Water intended for human consumption, surface water (from rivers).

At a glance

  • Accreditation number: PCA AB 1353
  • Methods in scope: 24
  • Types of test objects: 4
  • City: Oświęcim, Poland
Accreditation number
AB 1353
Accreditation body
PCA
Address
LABORATORIUM, ul. Ostatni Etap 6, 32-603 Oświęcim
City
Oświęcim, Poland

What this laboratory tests (4)

Accreditation scope — test methods (24)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
2 Water Sampling for chemical and physical testing Manual method PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5
3 Water intended for human consumption, water pH Range: (4,0 − 10,0) Potentiometric method PN-EN ISO 10523:2012
4 Water intended for human consumption, water Turbidity Range: (0,10 − 100) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
5 Water intended for human consumption, water Nitrate concentration Range: (1,00 – 60,0) mg/l Spectrophotometric method PB-04 wydanie 1 z dnia 01.12.2011 r. na podstawie testu Hach Lange Nr LCK 339
6 Water intended for human consumption, water Colour Range: (5 − 500) mg/l Pt Spectrophotometric method PB-01 wydanie 3 z dnia 11.08.2016 r. na podstawie metody Hach Nr 8025
7 Water intended for human consumption, water Electrical conductivity Range: (100 – 3000) μS/cm Conductometric method PN-EN 27888:1999
8 Water intended for human consumption, water Ammonium ion concentration Range: (0,10 − 2,5) mg/l Spectrophotometric method PB-03 wydanie 3 z dnia 18.04.2016 r. na podstawie testu Hach Lange Nr LCK 304
9 Water intended for human consumption, water Nitrite concentration Range: (0,050 − 0,6) mg/l Spectrophotometric method PB-05 wydanie 2 z dnia 01.06.2012 r. na podstawie testu Hach Lange Nr LCK 341
10 Water intended for human consumption, water Total iron concentration Range: (0,02 − 3,00) mg/l Spectrophotometric method PB-07 wydanie 1 z dnia 01.12.2011 r. na podstawie metody Hach Nr 8008
11 Water intended for human consumption, water Manganese concentration Range: (0,020 − 0,500) mg/l Spectrophotometric method PB-23 wydanie 1 z dnia 07.11.2024 r. na podstawie metody Hach Lange LCW 532
12 Water intended for human consumption, water Chloride concentration Range: (5,00 − 1000) mg/l Spectrophotometric method PB-06 wydanie 2 z dnia 01.06.2012 r. na podstawie testu Hach Lange Nr LCK 311
13 Water intended for human consumption, water Sulphate concentration Range: (5,0 − 300) mg/l Spectrophotometric method PB-09 wydanie 1 z dnia 01.12.2011 r. na podstawie metody Hach Nr 8051
14 Water intended for human consumption, water Total calcium and magnesium content (total hardness) Range: (20 − 600) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
15 Water intended for human consumption, water Calcium concentration Range: (10 − 100) mg/l Titrimetric method PN-ISO 6058:1999
16 Water intended for human consumption, surface water (from rivers) Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. pkt. 4.4.4
17 Water intended for human consumption, water Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
18 Water intended for human consumption, water Most probable number of Escherichia coli MPN method
19 Water intended for human consumption, water Most probable number of enterococci MPN method (Enterolert-DW test) PB-11 wydanie 5 z dnia 11.05.2017 r.
20 Water intended for human consumption, water Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
21 Water intended for human consumption, water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
22 Water intended for human consumption, water Total viable count at 22 °C Plate method (pour plate)
23 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04
24 Water intended for human consumption Escherichia coli count Membrane filtration method

Reference standards (21)

PB-01 wydanie 3 z dnia 11.08.2016 r. na podstawie metody Hach Nr 8025
PB-03 wydanie 3 z dnia 18.04.2016 r. na podstawie testu Hach Lange Nr LCK 304
PB-04 wydanie 1 z dnia 01.12.2011 r. na podstawie testu Hach Lange Nr LCK 339
PB-05 wydanie 2 z dnia 01.06.2012 r. na podstawie testu Hach Lange Nr LCK 341
PB-06 wydanie 2 z dnia 01.06.2012 r. na podstawie testu Hach Lange Nr LCK 311
PB-07 wydanie 1 z dnia 01.12.2011 r. na podstawie metody Hach Nr 8008
PB-09 wydanie 1 z dnia 01.12.2011 r. na podstawie metody Hach Nr 8051
PB-11 wydanie 5 z dnia 11.05.2017 r.
PB-23 wydanie 1 z dnia 07.11.2024 r. na podstawie metody Hach Lange LCW 532
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wył. pkt. 4.4.4
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12+A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999