🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1353 (Oświęcim, Poland). Its accreditation scope covers 24 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, water, Water intended for human consumption, Water, Water intended for human consumption, surface water (from rivers).
At a glance
- Accreditation number: PCA AB 1353
- Methods in scope: 24
- Types of test objects: 4
- City: Oświęcim, Poland
- Accreditation number
- AB 1353
- Accreditation body
- PCA
- Address
- LABORATORIUM, ul. Ostatni Etap 6, 32-603 Oświęcim
- City
- Oświęcim, Poland
What this laboratory tests (4)
- Water intended for human consumption, water — 19 methods
- Water intended for human consumption — 3 methods
- Water — 1 method
- Water intended for human consumption, surface water (from rivers) — 1 method
Accreditation scope — test methods (24)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 2 | Water | Sampling for chemical and physical testing Manual method | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 | ||
| 3 | Water intended for human consumption, water | pH Range: (4,0 − 10,0) Potentiometric method | PN-EN ISO 10523:2012 | ||
| 4 | Water intended for human consumption, water | Turbidity Range: (0,10 − 100) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 5 | Water intended for human consumption, water | Nitrate concentration Range: (1,00 – 60,0) mg/l Spectrophotometric method | PB-04 wydanie 1 z dnia 01.12.2011 r. na podstawie testu Hach Lange Nr LCK 339 | ||
| 6 | Water intended for human consumption, water | Colour Range: (5 − 500) mg/l Pt Spectrophotometric method | PB-01 wydanie 3 z dnia 11.08.2016 r. na podstawie metody Hach Nr 8025 | ||
| 7 | Water intended for human consumption, water | Electrical conductivity Range: (100 – 3000) μS/cm Conductometric method | PN-EN 27888:1999 | ||
| 8 | Water intended for human consumption, water | Ammonium ion concentration Range: (0,10 − 2,5) mg/l Spectrophotometric method | PB-03 wydanie 3 z dnia 18.04.2016 r. na podstawie testu Hach Lange Nr LCK 304 | ||
| 9 | Water intended for human consumption, water | Nitrite concentration Range: (0,050 − 0,6) mg/l Spectrophotometric method | PB-05 wydanie 2 z dnia 01.06.2012 r. na podstawie testu Hach Lange Nr LCK 341 | ||
| 10 | Water intended for human consumption, water | Total iron concentration Range: (0,02 − 3,00) mg/l Spectrophotometric method | PB-07 wydanie 1 z dnia 01.12.2011 r. na podstawie metody Hach Nr 8008 | ||
| 11 | Water intended for human consumption, water | Manganese concentration Range: (0,020 − 0,500) mg/l Spectrophotometric method | PB-23 wydanie 1 z dnia 07.11.2024 r. na podstawie metody Hach Lange LCW 532 | ||
| 12 | Water intended for human consumption, water | Chloride concentration Range: (5,00 − 1000) mg/l Spectrophotometric method | PB-06 wydanie 2 z dnia 01.06.2012 r. na podstawie testu Hach Lange Nr LCK 311 | ||
| 13 | Water intended for human consumption, water | Sulphate concentration Range: (5,0 − 300) mg/l Spectrophotometric method | PB-09 wydanie 1 z dnia 01.12.2011 r. na podstawie metody Hach Nr 8051 | ||
| 14 | Water intended for human consumption, water | Total calcium and magnesium content (total hardness) Range: (20 − 600) mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 15 | Water intended for human consumption, water | Calcium concentration Range: (10 − 100) mg/l Titrimetric method | PN-ISO 6058:1999 | ||
| 16 | Water intended for human consumption, surface water (from rivers) | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wył. pkt. 4.4.4 | ||
| 17 | Water intended for human consumption, water | Most probable number of coliform bacteria MPN method | PN-EN ISO 9308-2:2014-06 | ||
| 18 | Water intended for human consumption, water | Most probable number of Escherichia coli MPN method | |||
| 19 | Water intended for human consumption, water | Most probable number of enterococci MPN method (Enterolert-DW test) | PB-11 wydanie 5 z dnia 11.05.2017 r. | ||
| 20 | Water intended for human consumption, water | Enterococci count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 21 | Water intended for human consumption, water | Total viable count at 36 °C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 22 | Water intended for human consumption, water | Total viable count at 22 °C Plate method (pour plate) | |||
| 23 | Water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12+A1:2017-04 | ||
| 24 | Water intended for human consumption | Escherichia coli count Membrane filtration method | |||
Reference standards (21)
PB-01 wydanie 3 z dnia 11.08.2016 r. na podstawie metody Hach Nr 8025
PB-03 wydanie 3 z dnia 18.04.2016 r. na podstawie testu Hach Lange Nr LCK 304
PB-04 wydanie 1 z dnia 01.12.2011 r. na podstawie testu Hach Lange Nr LCK 339
PB-05 wydanie 2 z dnia 01.06.2012 r. na podstawie testu Hach Lange Nr LCK 341
PB-06 wydanie 2 z dnia 01.06.2012 r. na podstawie testu Hach Lange Nr LCK 311
PB-07 wydanie 1 z dnia 01.12.2011 r. na podstawie metody Hach Nr 8008
PB-09 wydanie 1 z dnia 01.12.2011 r. na podstawie metody Hach Nr 8051
PB-11 wydanie 5 z dnia 11.05.2017 r.
PB-23 wydanie 1 z dnia 07.11.2024 r. na podstawie metody Hach Lange LCW 532
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wył. pkt. 4.4.4
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12+A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999