🇵🇱 TARNOWSKIE WODOCIĄGI Sp. z o.o. PL

PCA AB 1350 • Tarnów, Poland • 79 methods

Water & wastewaterMicrobiology

TARNOWSKIE WODOCIĄGI Sp. z o.o. is a laboratory accredited by PCA under number AB 1350 (Tarnów, Poland). Its accreditation scope covers 79 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water (including swimming pool water), Water intended for human con…, Water, Water intended for human consumption, Wastewater, Water, Wastewater. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 1350
  • Methods in scope: 79
  • Types of test objects: 12
  • Techniques used: 16
  • City: Tarnów, Poland
Accreditation number
AB 1350
Accreditation body
PCA
Address
ul. Narutowicza 37, 33-100 Tarnów
City
Tarnów, Poland

What this laboratory tests (12)

Analytical techniques used (16)

Laboratory sections (2)

Laboratory locations

Accreditation scope — test methods (79)

No. Test object Methodology / Parameters Technique Reference document
Water Testing Laboratory
1 Water intended for human consumption Sampling for chemical, physical (including sensory) testing PN-ISO 5667-5:2017-10
2 Water intended for human consumption Presence of foreign taste
Regulated area: Badania wykonywane poza siedzibą Laboratorium
Qualitative method PN-EN 1622:2006
3 Water intended for human consumption Taste threshold number TFN
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
4 Water intended for human consumption Taste threshold number TFN
Range (1 – 8)
Full paired method, non-forced choice PN-EN 1622:2006
5 Water intended for human consumption Chloramine concentration (calculated)
Regulated area: Badania wykonywane poza siedzibą Laboratorium
PB-NL-FCH-16 wyd. 3 z 10.03.2026 r.
6 Water intended for human consumption Most probable number of intestinal enterococci MPN method PN-EN ISO 7899-3:2025-11
7 Surface water Sampling for chemical, physical (including sensory) testing PN-ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.5, 7.6
8 Surface water Temperature
Range (1,0 – 40,0) °C
PN-77/C-04584
9 Groundwater Sampling for chemical, physical (including sensory) testing PN-ISO 5667-11:2017-10 p. 5.3.2.2, 6.2
10 Swimming pool water Sampling for physical and chemical testing PB-NL-FCH-15 wyd. 3 z 10.03.2026 r.
11 Water (including swimming pool water) Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl
Range (200 – 800) mV
Regulated area: Badania wykonywane w siedzibie Laboratorium i poza nią
Potentiometric method PB-NL-FCH-17 wyd. 2 z 10.03.2026 r.
12 Water (including swimming pool water), Water intended for human consumption Turbidity
Range (0,10 – 100) NTU
Regulated area: Badania wykonywane w siedzibie Laboratorium i poza nią
Nephelometric method PN-EN ISO 7027-1:2016-09
13 Water (including swimming pool water), Water intended for human consumption Free chlorine concentration
Range (0,10 – 2,0) mg/l
Regulated area: Badania wykonywane poza siedzibą Laboratorium
Spectrophotometric method PB-NL-FCH-10 wyd. 4 z 10.03.2026 r. | na podstawie testów HACH nr 8021
14 Water (including swimming pool water), Water intended for human consumption Total chlorine concentration
Range (0,10 - 2,0) mg/l
Regulated area: Badania wykonywane poza siedzibą Laboratorium
Spectrophotometric method PB-NL-FCH-16 wyd. 3 z 10.03.2026 r. | na podstawie testów HACH nr 8167
15 Water (including swimming pool water), Water intended for human consumption Combined chlorine concentration (calculated)
Regulated area: Badania wykonywane poza siedzibą Laboratorium
PB-NL-FCH-16 wyd. 3 z 10.03.2026 r. | na podstawie testów HACH nr 8167
16 Water (including swimming pool water), Water intended for human consumption Aluminium concentration
Range (0,020 – 0,500) mg/l
Spectrophotometric method PN-92/C-04605.02
17 Water (including swimming pool water), Water intended for human consumption Iron concentration
Range (0,010 – 25) mg/l
Spectrophotometric method PN-ISO 6332:2001 Rozdział 7.1
18 Water (including swimming pool water), Water intended for human consumption Permanganate index
Range (0,7 – 40) mg/l
Titrimetric method PN-EN ISO 8467:2001
19 Water (including swimming pool water), Water intended for human consumption Nitrate nitrogen concentration
Range (0,040 – 500) mg/l
Spectrophotometric method PN-82/C-04576.08
20 Water (including swimming pool water), Water intended for human consumption Nitrate concentration (calculated) PN-82/C-04576.08
21 Water (including swimming pool water), Water intended for human consumption Chloride concentration
Range (5 – 4000) mg/l
Titrimetric method PN-ISO 9297:1994
22 Water (including swimming pool water), Water intended for human consumption pH
Range (2,0 – 12,0)
Regulated area: Badania wykonywane w siedzibie Laboratorium i poza nią
Potentiometric method PN-EN ISO 10523:2012
23 Water (including swimming pool water), Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
24 Water (including swimming pool water), Water intended for human consumption Temperature
Range (1,0 – 60,0) °C
PN-77/C-04584
25 Water (including swimming pool water), Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04
26 Water (including swimming pool water), Water intended for human consumption Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
27 Water (including swimming pool water), Water intended for human consumption Pseudomonas aeruginosa bacteria count Membrane filtration method PN-EN ISO 16266:2009
28 Water (including swimming pool water), Water intended for human consumption Count of bacteria of the genus Legionella
Matryca A: Procedura 5 (pożywka A – BCYE), 7 (pożywka C – GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08
29 Water (including swimming pool water), Water intended for human consumption Count of bacteria of the genus Legionella
Matrix B: Procedure 7 (medium C – GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08
30 Water (including swimming pool water), Water intended for human consumption Count of bacteria of the genus Legionella
Matryca A: Procedura 1 (pożywka A – BCYE i B – BCYE+AB)
Plate method (spread plate) PN-EN ISO 11731:2017-08
31 Water (including swimming pool water), Water intended for human consumption Count of bacteria of the genus Legionella
Matryca B: Procedura 1,2,3 (pożywka C – GVPC)
Plate method (spread plate) PN-EN ISO 11731:2017-08
32 Water (including swimming pool water), Water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000
33 Water, Water intended for human consumption Nitrite nitrogen concentration
Range (0,010 – 150) mg/l
Spectrophotometric method PN-EN 26777:1999
34 Water, Water intended for human consumption Nitrite concentration (calculated) PN-EN 26777:1999
35 Water, Water intended for human consumption Ammonium nitrogen concentration
Range (0,040 – 150) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
36 Water, Water intended for human consumption Ammonium ion concentration (calculated) PN-ISO 7150-1:2002
37 Water, Water intended for human consumption Ammonia concentration (calculated) PN-ISO 7150-1:2002
38 Water, Water intended for human consumption Colour
Range (2,5 – 500) mg/l Pt
Spectrophotometric method PB-NL-FCH-6 wyd. 5 z 10.03.2026 r.
39 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (10 – 1 000) mg/l
Titrimetric method PN-ISO 6059:1999
40 Water, Water intended for human consumption Sulfate concentration
Range (10 – 400) mg/l
Spectrophotometric method PB-NL-FCH-2 wyd. 5 z 10.03.2026 r. | na podstawie testów HACH nr 8051
41 Water, Water intended for human consumption Manganese concentration
Range (0,015 – 3,50) mg/l
Spectrophotometric method PB-NL-FCH-1 wyd. 5 z 10.03.2026 r. | na podstawie testów HACH nr 8149
42 Water, Water intended for human consumption Electrical conductivity
Range (5,0 – 5 000) μS/cm
Conductometric method PN-EN 27888:1999
43 Water, Water intended for human consumption Presence of foreign odour
Regulated area: Badania wykonywane poza siedzibą Laboratorium
Qualitative method PN-EN 1622:2006
44 Water, Water intended for human consumption Odour threshold number TON
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
45 Water, Water intended for human consumption Odour threshold number TON
Range (1 – 32)
Full paired method, non-forced choice PN-EN 1622:2006
46 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04
47 Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
48 Water, Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
49 Water, Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
50 Water, Water intended for human consumption Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
51 Water, Water intended for human consumption Clostridium perfringens bacteria count including spores Membrane filtration method PN-EN ISO 14189:2016-10
Wastewater Testing Laboratory
52 Wastewater Sampling for physical and chemical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
53 Wastewater Temperature
Range (1,0 – 50,0) °C
PN-77/C-04584
54 Wastewater Ammonium nitrogen concentration
Range (1,0 – 3000) mg/l
Titrimetric method PN-ISO 5664:2002
55 Wastewater Chemical oxygen demand - COD
Range (30 – 245000) mg/l O2
Titrimetric method PN-74/C-04578.03
56 Wastewater Electrical conductivity
Range (1,0 – 49) mS/cm
Conductometric method PN-EN 27888:1999
57 Wastewater Nitrate nitrogen concentration
Range (0,040 – 500) mg/l
Spectrophotometric method PN-82/C-04576.08
58 Wastewater Nitrate concentration (calculated) PN-82/C-04576.08
59 Wastewater Chloride concentration
Range (5 – 4000) mg/l
Titrimetric method PN-ISO 9297:1994
60 Wastewater Nitrite nitrogen concentration
Range (0,010 – 150) mg/l
Spectrophotometric method PN-EN 26777:1999
61 Wastewater Nitrite concentration (calculated) PN-EN 26777:1999
62 Wastewater Ammonium nitrogen concentration
Range (0,040 – 150) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
63 Wastewater Ammonium ion concentration (calculated) PN-ISO 7150-1:2002
64 Wastewater Ammonia concentration (calculated) PN-ISO 7150-1:2002
65 Water, Wastewater Total phosphorus concentration
Range (0,080 – 200) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010, Rozdział 7
66 Water, Wastewater Orthophosphate concentration
Range (0,040 – 40,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010, Rozdział 4
67 Water, Wastewater Kjeldahl nitrogen concentration
Range (0,50 – 5,0)
Spectrophotometric method PN-EN 25663-2001
68 Water, Wastewater Kjeldahl nitrogen concentration
Range (1,00 – 2 600) mg/l
Titrimetric method PN-EN 25663-2001
69 Water, Wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14
70 Water, Wastewater Total nitrogen concentration
Range (1,00 – 200) mg/l
Spectrophotometric method PB-NL-FCH-9 wyd. 4 z 10.03.2026 r. | na podstawie testów HACH nr LCK 138, LCK 238, LCK 338
71 Water, Wastewater Chemical oxygen demand - COD
Range (5,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
72 Water, Wastewater Biochemical oxygen demand - BOD5
Range (4 – 4000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
73 Water, Wastewater Biochemical oxygen demand - BOD5
Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
74 Water, Wastewater Phenol index
Range (0,018 – 15,0) mg/l
Spectrophotometric method PN-ISO 6439:1994
75 Water, Wastewater Sulfate concentration
Range (10 – 2000) mg/l
Gravimetric method PN-ISO 9280:2002
76 Rainwater, snowmelt water Sampling for physical and chemical testing Manual method PN-ISO 5667-10:2021-11
77 Rainwater, snowmelt water Temperature
Range (1,0 – 50,0) °C
PN-77/C-04584
78 Woda, Ścieki, Wody opadowe, wody roztopowe Total suspended solids (TSS)
Range (2,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
79 Wastewater, Rainwater, snowmelt water pH
Range (2,0 – 12,0)
Regulated area: Badania wykonywane w siedzibie Laboratorium i poza nią
Potentiometric method PN-EN ISO 10523:2012

Reference standards (53)

PB-NL-FCH-1 wyd. 5 z 10.03.2026 r.
PB-NL-FCH-10 wyd. 4 z 10.03.2026 r.
PB-NL-FCH-15 wyd. 3 z 10.03.2026 r.
PB-NL-FCH-16 wyd. 3 z 10.03.2026 r.
PB-NL-FCH-17 wyd. 2 z 10.03.2026 r.
PB-NL-FCH-2 wyd. 5 z 10.03.2026 r.
PB-NL-FCH-6 wyd. 5 z 10.03.2026 r.
PB-NL-FCH-9 wyd. 4 z 10.03.2026 r.
PN-73/C-04576.14
PN-74/C-04578.03
PN-77/C-04584
PN-82/C-04576.08
PN-92/C-04605.02
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663-2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010, Rozdział 4
PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010, Rozdział 7
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 7899-3:2025-11
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 p. 5.3.2.2, 6.2
PN-ISO 5667-5:2017-10
PN-ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.5, 7.6
PN-ISO 6059:1999
PN-ISO 6332:2001 Rozdział 7.1
PN-ISO 6439:1994
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-Z-11001-3:2000
na podstawie testów HACH nr 8021
na podstawie testów HACH nr 8051
na podstawie testów HACH nr 8149
na podstawie testów HACH nr 8167
na podstawie testów HACH nr LCK 138, LCK 238, LCK 338