🇵🇱 CENTRUM BADAŃ I DOZORU Sp. z o.o. PL
Materials & polymersConstruction
CENTRUM BADAŃ I DOZORU Sp. z o.o. is a laboratory accredited by PCA under number AB 1348 (Lędziny, Poland). Its accreditation scope covers 26 test methods in the following areas: Materials & polymers, Construction. Test objects include: Welded joints in metallic materials, Wires, Metal products and materials, Steel wire ropes. Most frequently used techniques: Ultrasonic method, Method: Vickers, Visual method.
At a glance
- Accreditation number: PCA AB 1348
- Methods in scope: 26
- Types of test objects: 16
- Techniques used: 6
- City: Lędziny, Poland
- Accreditation number
- AB 1348
- Accreditation body
- PCA
- Address
- ul. Lędzińska 8, 43-143 Lędziny, LABORATORIUM OŚRODKA RZECZOZNAWSTWA, I DOZORU URZĄDZEŃ GÓRNICZYCH
- City
- Lędziny, Poland
What this laboratory tests (16)
- Welded joints in metallic materials — 5 methods
- Wires — 4 methods
- Metal products and materials — 3 methods
- Steel wire ropes — 2 methods
- Capacitive voltage detectors — 1 method
- Electrical insulating matting — 1 method
- Ferromagnetic metal products and materials including: castings, forgings, welded joints, sheets — 1 method
- Flat steel products — 1 method
- Gloves of insulating material — 1 method
- Insulating poles — 1 method
- Metal products — 1 method
- Metal products and materials including: castings, forgings, sheets — 1 method
- Metal products and materials including: castings, forgings, welded joints, sheets — 1 method
- Protective footwear — 1 method
- Steel and steel-rubber ropes — 1 method
- and 1 more
Analytical techniques used (6)
- Ultrasonic method — 4 methods
- Method: Vickers — 2 methods
- Visual method — 2 methods
- Magnetic particle method — 1 method
- Magnetic rope testing method — 1 method
- Penetrant testing method — 1 method
Laboratory locations
- LABORATORIUM OŚRODKA RZECZOZNAWSTWA — AB 1348 ul. Fabryczna 20
- Laboratorium Ośrodka Rzeczoznawstwa i Dozoru Urządzeń Górniczych — ul. Fabryczna 20, 41-404 Mysłowice
Accreditation scope — test methods (26)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory of the Centre for Expert Assessment and Supervision of Mining Equipment | |||||
| 1 | Welded joints in metallic materials | Welding imperfections | Ultrasonic method | PN-EN ISO 17640:2019-01 | PN-EN ISO 16810:2025-04 | |
| 2 | Flat steel products | Discontinuities | Ultrasonic method | PN-EN 10160:2001 | PN-EN ISO 16810:2025-04 | |
| 3 | Steel forgings | Discontinuities | Ultrasonic method | PN-EN ISO 16810:2025-04 | PN-EN 10228-3:2016-07 | |
| 4 | Metal products | Thickness Range (0,5-300) mm |
Ultrasonic method | PN-EN ISO 16809:2025-12 | |
| 5 | Ferromagnetic metal products and materials including: castings, forgings, welded joints, sheets | Surface and subsurface discontinuities | Magnetic particle method | PN-EN ISO 9934-1:2017-02 | |
| 6 | Metal products and materials including: castings, forgings, welded joints, sheets | Surface discontinuities | Penetrant testing method | PN-EN ISO 3452-1:2021-12 | |
| 7 | Metal products and materials including: castings, forgings, sheets | Shape imperfections and surface discontinuities | Visual method | PN-EN 13018:2016-04 | |
| 8 | Welded joints in metallic materials | Welding imperfections | Visual method | PN-EN ISO 17637:2017-02 | |
| 9 | Steel and steel-rubber ropes | Discontinuities and change in the metallic cross-section of the rope Range of rope diameters (6 - 70) mm Speed range (0,5 - 2,0) m/s |
Magnetic rope testing method | PN-EN 12927-8:2006 | PN-EN 12927:2019-07 | PN-G-46603:1992 | PN-G-46604:1992 | |
| 10 | Wires | Wire diameter, Dimensional measurement, Range up to 10 mm | PN-ISO 3154:1997 pkt. 5.2.2 | ||
| 11 | Wires | Tensile test, Actual breaking force Fm, Tensile strength Rm, Force range up to 100 kN | PN-EN ISO 6892-1:2020-05 metoda B | ||
| 12 | Wires | Resistance to torsion in one direction Diameter range (0,3 - 5) mm |
PN-ISO 7800:1996 | ||
| 13 | Wires | Resistance to reverse bending Diameter range (0,5 - 8,0) mm |
PN-ISO 7801:1996 | ||
| 14 | Steel wire ropes | Dimensional measurement, Rope diameter, Range up to 50 mm | PN-ISO 3154:1997 pkt. 5.1.1 | ||
| 15 | Steel wire ropes | Tensile test, Actual breaking force Fm, Force range up to 1000 kN | PN-EN 12385-1:2009 Metoda 1 | PN-ISO 3154:1997 Metoda B | ||
| 16 | Metal products and materials | Mechanical properties: Force Fm Yield strength Re Proof strength, plastic extension Rp Tensile strength Rm Elongation A Reduction of area Z Force range do 1000 kN Tensile test at room temperature |
PN-EN ISO 6892-1:2020-05 Metoda B | ||
| 17 | Metal products and materials | Mechanical properties: Force Fm Yield strength Re Proof strength, plastic extension Rp Tensile strength Rm Elongation A Reduction of area Z Force range do 100 kN Temperature range: up to +800°C Tensile test at elevated temperature |
PN-EN ISO 6892-2:2018-08 Metoda B | ||
| 18 | Welded joints in metallic materials | Mechanical properties: Force Fm Tensile strength Rm Force range do 1000 kN Tensile test at room temperature |
PN-EN ISO 4136:2022-12 | PN-EN ISO 6892-1:2020-05 Metoda B | ||
| 19 | Welded joints in metallic materials | Mechanical properties: Force Fm Tensile strength Rm Force range do 100 kN Temperature range: up to +800°C Tensile test at elevated temperature |
PN-EN ISO 4136:2022-12 | PN-EN ISO 6892-2:2018-08 Metoda B | ||
| 20 | Metal products and materials | HV hardness Range HV1, HV2, HV3, HV5, HV10, HV30 |
Method: Vickers | PN-EN ISO 6507-1:2024-04 | |
| 21 | Welded joints in metallic materials | HV hardness Range HV1, HV2, HV3, HV5, HV10, HV30 |
Method: Vickers | PN-EN ISO 9015-1:2011 | PN-EN ISO 6507-1:2024-04 | |
| 22 | Protective footwear | Dielectric strength at AC voltage Up range (1 – 100) kV |
PN-EN 50321-1:2018-05, p. 5.2 PB/DM/PE, wyd. II z dnia 07.03.2023 (wg normy PN-77/C-94136) | ||
| 23 | Gloves of insulating material | Dielectric strength at AC voltage Up range (1 – 100) kV |
PN-EN 60903:2006, p. 8.4.2.1 | ||
| 24 | Electrical insulating matting | Electric strength at alternating voltage (excluding conditioning in water) Up range (1 – 100) kV |
PN-EN 61111:2009, p. 5.6.4.2 | ||
| 25 | Insulating poles | Dielectric strength at AC voltage Up range (1 – 100) kV |
PN-EN 60832-1:2010, p. 5.7.1.1.1 | ||
| 26 | Capacitive voltage detectors | Unambiguity of signalling Un range (1 – 52) kV Functional tests excluding type testing |
PN-EN IEC 61243-1:2022-01 p. 6.2.1 | ||
Reference standards (30)
PN-EN 10160:2001
PN-EN 10228-3:2016-07
PN-EN 12385-1:2009 Metoda 1
PN-EN 12927-8:2006
PN-EN 12927:2019-07
PN-EN 13018:2016-04
PN-EN 50321-1:2018-05, p. 5.2 PB/DM/PE, wyd. II z dnia 07.03.2023 (wg normy PN-77/C-94136)
PN-EN 60832-1:2010, p. 5.7.1.1.1
PN-EN 60903:2006, p. 8.4.2.1
PN-EN 61111:2009, p. 5.6.4.2
PN-EN IEC 61243-1:2022-01 p. 6.2.1
PN-EN ISO 16809:2025-12
PN-EN ISO 16810:2025-04
PN-EN ISO 17637:2017-02
PN-EN ISO 17640:2019-01
PN-EN ISO 3452-1:2021-12
PN-EN ISO 4136:2022-12
PN-EN ISO 6507-1:2024-04
PN-EN ISO 6892-1:2020-05 Metoda B
PN-EN ISO 6892-1:2020-05 metoda B
PN-EN ISO 6892-2:2018-08 Metoda B
PN-EN ISO 9015-1:2011
PN-EN ISO 9934-1:2017-02
PN-G-46603:1992
PN-G-46604:1992
PN-ISO 3154:1997 Metoda B
PN-ISO 3154:1997 pkt. 5.1.1
PN-ISO 3154:1997 pkt. 5.2.2
PN-ISO 7800:1996
PN-ISO 7801:1996