🇵🇱 LABORATORIUM BADAŃ ŚRODOWISKOWYCH PL

PCA AB 1326 • Bielawa (działalność techniczna), Poland • 18 methods

EnvironmentConstruction

LABORATORIUM BADAŃ ŚRODOWISKOWYCH is a laboratory accredited by PCA under number AB 1326 (Bielawa (działalność techniczna), Poland). Its accreditation scope covers 18 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment - air, Workplace environment - emergency lighting, Workplace environment - hand-arm vibration, Workplace environment - noise.

At a glance

  • Accreditation number: PCA AB 1326
  • Methods in scope: 18
  • Types of test objects: 8
  • City: Bielawa (działalność techniczna), Poland
Accreditation number
AB 1326
Accreditation body
PCA
Address
PACHOREK – JUROWSKA sp. j., ul. Grabowa 10, 58-200 Dzierżoniów, ul. 3-go Maja 53/1, 58-260 Bielawa (działalność techniczna)
City
Bielawa (działalność techniczna), Poland

What this laboratory tests (8)

Accreditation scope — test methods (18)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level Range: (25 - 135) dB C-weighted peak sound level Range: (40 - 138) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 Z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11
2 Workplace environment - noise Noise exposure level referred to: - an 8-hour daily working time - an average weekly working time (calculated)
3 Workplace environment - whole-body vibration Frequency-weighted effective vibration acceleration Range: (0,06 - 10) m/s2 Direct measurement method PN-EN 14253+A1:2011
4 Workplace environment - whole-body vibration Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4a , 1.4a , a ) wx wy wz Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4a , 1.4a , a ) wx wy wz (calculated)
5 Workplace environment - hand-arm vibration RMS frequency-weighted vibration acceleration Range: (0,06 - 100) m/s2 Direct measurement method PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004+A1:2015-11
6 Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (a , a , a ) hwx hwy hwz Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (a , a , a ) hwx hwy hwz (calculated)
7 Workplace environment Illuminance Range: (5 - 10000) lx Direct measurement method PB-01 wydanie 3 z dnia 02.11.2022 r.
8 indoors Illuminance uniformity (calculated)
9 Workplace environment - emergency lighting Illuminance Range: (0,5 - 3000) lx Direct measurement method PN-EN 1838:2013-11 z wyłączeniem p.4.2.3-4.2.6
10 Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated)
11 Workplace environment - emergency lighting Illuminance uniformity for the high-risk zone (calculated)
12 Workplace environment - air Sampling for assessment of occupational exposure to: - dust agents - inhalable fraction - respirable fraction Personal dosimetry method PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004
13 Workplace environment - air Sampling for occupational exposure assessment to: - organic substances, - inorganic substances - inhalable fraction - respirable fraction - metals and their compounds, including - inhalable fraction - respirable fraction Personal dosimetry method Stationary method
14 Workplace environment - air Exposure index (calculated)
15 Workplace environment - air Concentration of harmful dust agents – inhalable fraction: - apatites and phosphorites - petroleum asphalt - Portland cement - titanium dioxide - natural graphite - synthetic graphite - kaolin - amorphous and synthetic silica - wood dust - flour dust - dusts not classified according to toxicity - organic dusts of animal and plant origin except wood and flour dust - carbon black - calcium sulphate (VI) (gypsum) - coal (hard, brown) - magnesium calcium carbonate (dolomite) - silicon carbide, non-fibrous Range: (0,2 – 34) mg/m3 Gravimetric method PN-Z-04507:2022-05+Ap1:2022-08
16 Workplace environment - air Concentration of harmful dust agents – respirable fraction : - apatites and phosphorites - Portland cement - natural graphite - amorphous and synthetic silica - organic dusts of animal and plant origin except wood and flour dust - coal (hard, brown) Range: (0,14 - 37) mg/m3 Gravimetric method PN-Z-04508:2022-05+Ap1:2022-08
17 Workplace environment - air Carbon monoxide concentration Range: (2,3 - 232) mg/m3 Range: (2-200) ppm Electrochemical method PB-03 wydanie 3 z dnia 17.10.2025 r.
18 Workplace environment - air samples collected on filters - air Content/concentration of crystalline silica (quartz, cristobalite) – respirable fraction Range:(0,006 – 0,400) mg in the sample (0,009 – 0,585) mg/m3 Fourier transform infrared spectrometry (FT-IR) method Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130

Reference standards (10)

PB-01 wydanie 3 z dnia 02.11.2022 r.
PB-03 wydanie 3 z dnia 17.10.2025 r.
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 z wyłączeniem p.4.2.3-4.2.6
PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004+A1:2015-11
PN-N-01307:1994 PN-EN ISO 9612:2011 Z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11
PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05+Ap1:2022-08
Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130