🇵🇱 CENTRUM BADAŃ ŚRODOWISKA „SORBCHEM” Sp. z o.o. PL

PCA AB 1302 • Ruda Śląska, Poland • 228 methods

EnvironmentWater & wastewaterPetrochemistry & fuelsMaterials & polymers

CENTRUM BADAŃ ŚRODOWISKA „SORBCHEM” Sp. z o.o. is a laboratory accredited by PCA under number AB 1302 (Ruda Śląska, Poland). Its accreditation scope covers 228 test methods in the following areas: Environment, Water & wastewater, Petrochemistry & fuels, Materials & polymers. Test objects include: Workplace environment - air, Waste gases, Heating boilers for solid fuels with manual and automatic fuel feeding, Water, wastewater. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Inductively coupled plasma optical emission spectrometry (ICP-OES), Flame atomic absorption spectrometry (FAAS).

At a glance

  • Accreditation number: PCA AB 1302
  • Methods in scope: 228
  • Types of test objects: 23
  • Techniques used: 42
  • City: Ruda Śląska, Poland
Accreditation number
AB 1302
Accreditation body
PCA
Address
LABORATORIUM, ul. Kokotek 6, 41-700 Ruda Śląska
City
Ruda Śląska, Poland

What this laboratory tests (23)

Analytical techniques used (42)

Accreditation scope — test methods (228)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (26 – 135) dB C-weighted peak sound pressure level Range (40 – 138) dB
Direct measurement method PN-N-01307:1994 | PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10
2 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10
3 Workplace environment − emergency lighting Illuminance
Range (0,5 – 200) lx
Direct measurement method PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
4 Workplace environment − emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
5 Workplace environment − emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
6 Workplace environment − emergency lighting Closing time
Range (3-90) s
Direct measurement method PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
7 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (26 – 135) dB
Direct measurement method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
8 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
9 Machinery and equipment - noise Sound pressure level
weighted with the characteristic frequency weighting A Range (26 − 135) dB
Direct measurement method PN-EN ISO 3746:2011 z wyłączeniem punktu 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09
10 Machinery and equipment - noise Sound power level (calculated) PN-EN ISO 3746:2011 z wyłączeniem punktu 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09
11 Workplace environment - electric lighting Illuminance
Range (5 – 5000) lx
Direct measurement method PN-83/E-04040.03
12 Workplace environment - electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
13 Workplace environment – energy expenditure Air temperature
Range (0 – 40) °C Air flow Range (10 - 60) dm3/min
Direct measurement method Procedura Badawcza PB-51 wydanie 5 z dnia 10.06.2025 r.
14 Workplace environment – energy expenditure Energy expenditure (calculated) Procedura Badawcza PB-51 wydanie 5 z dnia 10.06.2025 r.
15 Workplace environment − moderate microclimate Air temperature
Range (10,0 – 30,0) 0C Black globe temperature Range (10,0 – 40,0) 0C Air humidity Range (20,0 – 90,0) % Air velocity Range (0,15 – 4,0) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
16 Workplace environment − moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
17 Workplace environment − hot microclimate Air temperature
Range (15,0 – 60,0) 0C Natural wet bulb temperature Range (15,0 – 60,0) 0C Black globe temperature Range (15,0 – 40,0) 0C
Direct measurement method PN-EN ISO 7243:2018-01
18 Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
19 Workplace environment − cold microclimate Air temperature
Range (-10,0 – 10,0) 0C Black globe temperature Range (-10,0 – 15,0) 0C Air humidity Range (20,0 – 90,0) % Air velocity Range (0,4 – 4,0) m/s
Direct measurement method PN-EN ISO 11079:2008
20 Workplace environment − cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
21 Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,02 – 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11
22 Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11
23 Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,02 – 100) m/s2
Direct measurement method PN-EN 14253+A1:2011
24 Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
25 Workplace environment - air Sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
26 Workplace environment - air Sampling for occupational exposure assessment to inorganic substances Stationary method PN-Z-04008-7:2002+Az1:2004
27 Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
28 Workplace environment - air Concentration of harmful dust agents - inhalable fraction
Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,19 – 20,4) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
29 Workplace environment - air Concentration of dust agents harmful to health- respirable fraction
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,10 – 6,2) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
30 Workplace environment - air Carbon monoxide concentration
Range (2,3 – 234) mg/m3 Range (2,0 – 201) ppm
Electrochemical method Procedura Badawcza PB-01 wydanie 8 z dnia 24.06.2019 r.
31 Workplace environment - air Exposure indices (calculated) Procedura Badawcza PB-01 wydanie 8 z dnia 24.06.2019 r.
32 Workplace environment - air Crystalline silica (quartz, cristobalite) concentration/content
respirable fraction Range (0,010 – 0,4) mg/m3 Range (10,0 – 400) μg w próbce
Fourier transform infrared spectrometry (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130
33 Workplace environment - air Ammonia concentration/ content
Range (1 – 100) mg/m3 Range (0,015 – 1,5) mg w próbce
Spectrophotometric method PN-71/Z-04041
34 Workplace environment - air Stężenie/ zawartość tlenku azotu i ditlenku azotu
NO (0,09 – 10,4) mg/m3 Range (0,072 – 8,4) ppm Range (0,00045 – 0,052) mg w próbce NO2 (0,07 – 8,0) mg/m3 (0,037 – 4,2) ppm (0,00035 – 0,040) mg w próbce
Spectrophotometric method PN-Z-04009-11:2008
35 Workplace environment - air Concentration/ content of formaldehyde
Range (0,033 – 2,50) mg/m3 Range (0,0008 – 0,060) mg w próbce
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, str. 96-100
36 Workplace environment - air Stężenie/ zawartość akrylaldehydu
Range (0,005 – 2,5) mg/m3 Range (0,0021 – 1,1) ppm Range (0,00012 – 0,060) mg w próbce
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) PN-Z-04045-16:2010
37 Workplace environment - air Stężenie/ zawartość 1-metoksypropan-2-olu
Range (4,44 – 950) mg/m3 Range (0,020 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04354:2005
38 Workplace environment - air Concentration/ content of benzene
Range (0,064 – 1,5) mg/m3 Range (0,020 – 0,46) ppm Range (0,00128 – 0,030) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04016-10:2005
39 Workplace environment - air Concentration/ content of styrene
Range (1,11 – 200) mg/m3 Range (0,005 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-86/Z-04152/02
40 Workplace environment - air Concentration/ content of methanol
Range (2,78 – 1000) mg/m3 Range (0,0125 – 5,0) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04476:2016-10
41 Workplace environment - air Stężenie/ zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych - frakcja wdychalna
Range (0,4 – 32) mg/m3 Range (0,2– 3,2) mg w próbce
Fourier transform infrared spectrometry (FT-IR) PN-Z-04108-5:2006
42 Workplace environment - air Concentration/ content of ethylbenzene
Range (1,11 – 800) mg/m3 Range (0,005 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-79/Z-04081/01
43 Workplace environment - air Concentration/ content of propan-2-ol
Range (36 – 2400) mg/m3 Range (0,162 – 16,2) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103), str. 157-170
44 Workplace environment - air Concentration / content of acetone
Range (1,11 – 3600) mg/m3 Range (0,005 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
45 Workplace environment - air Concentration/ content of ethanol
Range (2,22 – 4222) mg/m3 Range (0,010 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) Procedura Badawcza PB-55 wydanie 1 z dnia 10.09.2020 r.
46 Workplace environment - air Concentration/ content of butan-1-ol
Range (1,11 – 300) mg/m3 Range (0,005 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
47 Workplace environment - air Concentration/ content of ethyl acetate
Range (1,11 – 3000) mg/m3 Range (0,304 – 821) ppm Range (0,005 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
48 Workplace environment - air Stężenie/ zawartość octanu n-butylu
Range (1,11 – 1500) mg/m3 Range (0,005 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
49 Workplace environment - air Concentration/ content of xylene (mixture of isomers)
Range (1,11 – 400) mg/m3 Range (0,005 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
50 Workplace environment - air Concentration/ content of toluene
Range (1,11 – 400) mg/m3 Range (0,005 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
51 Workplace environment - air Concentration/ content of tetrachloroethene
Range (1,11 – 340) mg/m3 Range (0,161 – 49) ppm Range (0,005 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-83/Z-04118/02
52 Workplace environment - air Concentration/ content of hexane
Range (1,11 – 144) mg/m3 Range (0,005 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04136-3:2003
53 Workplace environment - air Stężenie/ zawartość butan-2-onu (metyloetyloketonu)
Range (1,11 – 1800) mg/m3 Range (0,005 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-79/Z-04107/02
54 Workplace environment - air Concentration/ content of acetic acid
Range (0,8 – 100) mg/m3 Range (0,32 – 40) ppm Range (0,02 – 1,25) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04323:2004
55 Workplace environment - air Concentration/ content of phenol
Range (0,21 – 32) mg/m3 Range (0,005 – 0,500) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, str. 91-95
56 Workplace environment - air Stężenie/ zawartość pentanu
Range (4,44 – 6000) mg/m3 Range (0,020 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-84/Z 04135/02
57 Workplace environment - air Concentration/ content of heptane
Range (4,44 – 4000) mg/m3 Range (0,020 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-84/Z 04138/02
58 Workplace environment - air Stężenie/ zawartość oktanu
Range (4,44 – 3600) mg/m3 Range (0,02 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-86/Z 04166/02
59 Workplace environment - air Stężenie/ zawartość benzyny C do lakierów
Range (4,44 – 1800) mg/m3 Range (0,02 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-81/Z-04134/03
60 Workplace environment - air Concentration/ content of extraction naphtha
Range (4,44 – 3000) mg/m3 Range (0,02 – 19) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-81/Z 04134/02
61 Workplace environment - air Stężenie/ zawartość glinu metalicznego, glin proszek (niestabilizowany) – frakcja wdychalna
Range (0,10 – 10,0) mg/m3 respirable fraction Range (0,11 – 10,00) mg/m3 Range (0,075 – 7,5) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04263-1:2012
62 Workplace environment - air Stężenie/ zawartość tritlenku glinu w przeliczeniu na Al – frakcja wdychalna
Range (0,10 – 10,0) mg/m3 – respirable fraction Range (0,11 – 11,0) mg/m3 Range (0,075 – 7,5) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04263-1:2012
63 Workplace environment - air Concentration/ content of metallic nickel
Range (0,010 – 1,0) mg/m3 Range (0,0075 – 0,75) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04502:2019-10
64 Workplace environment - air Stężenie/ zawartość związków niklu w przeliczeniu na Ni
inhalable fraction Range (0,010 – 1,0) mg/m3 respirable fraction Range (0,0095 – 0,95) mg/m3 Range (0,0075 – 0,75) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04502:2019-10
65 Workplace environment - air Stężenie / zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) - w przeliczeniu na Cr
Range (0,017 – 3,5) mg/m3 Range (0,013– 2,5) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04434:2011
66 Workplace environment - air Stężenie/ zawartość chromu metalicznego, Związki chromu (II) w przeliczeniu na chrom (II), Związki chromu (III)w przeliczeniu na chrom (III) (z obliczeń) Procedura Badawcza PB-57 wydanie 1 z dnia 16.04 2021 r.
67 Workplace environment - air Stężenie/zawartość tlenku cynku w przeliczeniu na Zn -frakcja wdychalna
Range (0.014 – 10,0) mg/m3 Range (0,01 – 7,5) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-87/Z-04100.03
68 Workplace environment - air Stężenie/ zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn -frakcja wdychalna
Range (0,005 – 1,0) mg/m3 -respirable fraction Range (0,0047 – 0,95) mg/m3 Range (0,0037– 0,75) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04472:2015-10+Ap1:2015-12
69 Workplace environment - air Concentration/ content of copper and its inorganic compounds calculated as Cu
Range (0,005 – 1,0) mg/m3 Range (0,0037 – 0,75) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04106-3:2002
70 Workplace environment - air Concentration/ content of iron oxides calculated as Fe Iron (III) oxide Iron (II) oxide Triiron tetraoxide
inhalable fraction Range (0,02 – 8,0) mg/m3 -respirable fraction Range (0,02 – 8,0) mg/m3 Range (0,015 – 6) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04469:2015-10
71 Workplace environment - air Concentration/ content of lead and its inorganic compounds - calculated as Pb
inhalable fraction Range (0,005 – 1,0) mg/m3 Range (0,0035 – 0,7) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04487:2017-10
72 Workplace environment - air Concentration/ content of manganese and its inorganic compounds calculated as Mn
inhalable fraction Range (0,00347 – 0,69) mg/m3 Range (0,0025 – 0,50) mg w próbce respirable fraction Range (0,00316 – 0,63) mg/m3 Range (0,0025 – 0,50) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
73 Workplace environment - air Concentration/ content of iron oxides calculated as Fe Iron (III) oxide Iron (II) oxide Triiron tetraoxide
inhalable fraction Range (0,069 – 20,0) mg/m3 Range (0,050 – 10,0) mg w próbce respirable fraction Range (0,063 – 10,0) mg/m3 Range (0,050 – 10,0) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
74 Workplace environment - air Stężenie/ zawartość srebra
Range (0,00347 – 0,139) mg/m3 Range (0,0025 – 0,100) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
75 Workplace environment - air Stężenie/ zawartość glinu metalicznego, glin proszek (niestabilizowany) – frakcja wdychalna
Range (0,069 – 6,9) mg/m3 Range (0,050 – 5,0) mg w próbce respirable fraction Range (0,063 – 6,3) mg/m3 Range (0,050 – 5,0) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
76 Workplace environment - air Stężenie/ zawartość tritlenku glinu w przeliczeniu na Al – frakcja wdychalna
Range (0,069 – 6,9) mg/m3 Range (0,050 – 5,0) mg w próbce – respirable fraction Range (0,063 – 6,3) mg/m3 Range (0,050 – 5,0) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
77 Workplace environment - air Concentration/ content of calcium oxide
inhalable fraction Range (0,053 – 12,0) mg/m3 Range (0,0378 – 3,78) mg w próbce respirable fraction Range (0,048 – 8,0) mg/m3 Range (0,0378 – 3,78) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
78 Workplace environment - air Concentration/ content of calcium hydroxide
inhalable fraction Range (0,069 – 12,0) mg/m3 Range (0,050 – 5,0) mg w próbce respirable fraction Range (0,063 – 8,0) mg/m3 Range (0,050 – 5,0) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
79 Workplace environment - air Concentration/ content of cadmium and its inorganic compounds calculated as Cd
inhalable fraction Range (0,00035 – 0,0139) mg/m3 Range (0,00025 – 0,0100) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
80 Workplace environment - air Concentration/ content of cobalt and its inorganic compounds calculated as Co
Range (0,00139 – 0,069) mg/m3 Range (0,00100 – 0,050) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
81 Workplace environment - air Stężenie / zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI)
calculated as Cr Range (0,0347 – 1,39) mg/m3 Range (0,0250 – 1,00) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
82 Workplace environment - air Concentration/ content of copper and its inorganic compounds calculated as Cu
Range (0,0139 – 0,69) mg/m3 Range (0,0100 – 0,50) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
83 Workplace environment - air Stężenie/ zawartość wodorotlenku potasu
Range (0,0139 – 2,00) mg/m3 Range (0,0100 – 1,00) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
84 Workplace environment - air Stężenie/ zawartość wodorotlenku sodu
Range (0,0139 – 2,00) mg/m3 Range (0,0100 – 1,00) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
85 Workplace environment - air Concentration/ content of metallic nickel
Range (0,00069 – 0,69) mg/m3 Range (0,00050 – 0,50) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
86 Workplace environment - air Stężenie/ zawartość związków niklu w przeliczeniu na Ni
inhalable fraction Range (0,00069 – 0,69) mg/m3 Range (0,00050 – 0,50) mg w próbce respirable fraction Range (0,00063 – 0,63) mg/m3 Range (0,00050 – 0,50) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
87 Workplace environment - air Concentration/ content of lead and its inorganic compounds - calculated as Pb
inhalable fraction Range (0,00347 – 0,139) mg/m3 Range (0,00250 – 0,100) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
88 Workplace environment - air Stężenie/ zawartość cyny i jej związków nieorganicznych, z wyjątkiem stannanu – w przeliczeniu na Sn
inhalable fraction Range (0,139 – 6,9) mg/m3 Range (0,100 – 5,0) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
89 Workplace environment - air Stężenie/ zawartość tytanu i jego związków – w przeliczeniu na Ti
Range (0,347 – 60) mg/m3 Range (0,250 – 15,0) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
90 Workplace environment - air Stężenie/zawartość tlenku cynku w przeliczeniu na Zn -frakcja wdychalna
Range (0,139 – 20,0) mg/m3 Range (0,100 – 10,0) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
91 Workplace environment - air Nitrogen oxide concentration / content
Range (0,125 – 14,6) mg/m3 Range (0,100 – 11,7) ppm Range (0,003 – 0,35) mg w próbce
Ion chromatography with conductometric detection (IC-CD) OSHA Method 190
92 Workplace environment - air Nitrogen dioxide concentration / content
Range (0,063 – 4,20) mg/m3 Range (0,033 – 2,2) ppm Range (0,0015 – 0,10) mg w próbce
Ion chromatography with conductometric detection (IC-CD) OSHA Method 182
93 Workplace environment - air Concentration / content of sulphur dioxide
Range (0,046 – 6,9) mg/m3 Range (0,017 – 2,6) ppm Range (0,033 – 5,0) mg w próbce
Ion chromatography with conductometric detection (IC-CD) OSHA Method 1011
94 Workplace environment - air Hydrogen sulphide concentration / content
Range (0,63 – 14,6) mg/m3 Range (0,015 – 0,35) mg w próbce
Ion chromatography with conductometric detection (IC-CD) OSHA Method 1008
95 Workplace environment - air Concentration / content of sulphuric (VI) acid – thoracic fraction
Range (0,0043 – 0,17) mg/m3 Range (0,0025 – 0,10) mg w próbce
Ion chromatography with conductometric detection (IC-CD) Podstawy i Metody Oceny Środowiska Pracy 2017 nr 2(92), str. 5-19
96 Workplace environment - air Hydrogen chloride concentration / content
Range (0,14 – 20,8) mg/m3 Range (0,10 – 15) mg w próbce
Ion chromatography with conductometric detection (IC-CD) NIOSH 7907 Method, Issue 1, 20 May 2014
97 Workplace environment - air Concentration / content of nitric (V) acid
Range (0,035 – 7,1) mg/m3 Range (0,025 – 5,1) mg w próbce
Ion chromatography with conductometric detection (IC-CD) NIOSH 7907 Method, Issue 1, 20 May 2014
98 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa
Velocity Range (1,0 – 35) m/s
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Stagnation pressure method; Anemometric method PN-Z-04030-7:1994
99 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-Z-04030-7:1994
100 Waste gases Dust concentration
Range (0,001 – 10) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Gravimetric method PN-Z-04030-7:1994
101 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-Z-04030-7:1994
102 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 13284-1:2018-02
103 Waste gases Dust concentration
Range (1,0 – 50) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Gravimetric method PN-EN 13284-1:2018-02
104 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 13284-1:2018-02
105 Waste gases Stężenie CO, SO2, CO2, NOX, O2
O2 (1,0 – 21) % CO2 (0,1 – 20) % CO (2,0 – 1400) mg/m3 SO2 (3,0 – 3000) mg/m3 NO (9 – 435) mg/m3 NOx (14 – 700) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Metoda elektrochemiczna; Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) PN-ISO 10396:2001
106 Waste gases Emisja CO, SO2, CO2, NO, NOX (NO i NO2 w przeliczeniu na NO2) (z obliczeń)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-ISO 10396:2001
107 Waste gases CO concentration
Range (2,0 – 1400) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) PN-EN 15058:2017-04
108 Waste gases CO emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 15058:2017-04
109 Waste gases NO, NOx concentration
NO (1,3 – 435) mg/m3 NOx (2,0 – 700) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Chemiluminescence method (CLD) PN-EN 14792:2017-04
110 Waste gases Emission of NO, NOx (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 14792:2017-04
111 Waste gases Sampling for determination of SO2 concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 14791:2017-04
112 Waste gases SO2 concentration
Range (5,0 – 2000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Thoron method PN-EN 14791:2017-04
113 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 14791:2017-04
114 Waste gases Water vapour concentration (H2O)
Range (4,0 – 40) % Range (29 – 250) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Condensation-absorption method PN-EN 14790:2017-04
115 Waste gases Oxygen concentration
Range (3,0 – 21,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Paramagnetic method PN-EN 14789:2017-04 | PN-ISO 10396:2001
116 Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (1,8 – 1000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Metoda ciągłej detekcji płomieniowo-jonizacyjną (FID) PN-EN 12619:2013-05
117 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 12619:2013-05
118 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 13649:2005
119 Waste gases Stężenie/ zawartość indywidualnych gazowych związków organicznych
acetone (0,5 – 1900) mg/m3 Range (0,005 – 19) mg w próbce butan-1-ol (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce etanolu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce metanolu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce octanu etylu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce octanu butylu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce toluenu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce ksylenu (mieszanina izomerów) (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce benzenu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce etylobenzenu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce butan-2-on (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Gas chromatography with flame ionization detection (GC - FID) PN-EN 13649:2005
120 Waste gases Stężenie/ zawartość indywidualnych gazowych związków organicznych
acetic acid Range (0,5 – 125) mg/m3 Range (0,005 – 1,25) mg w próbce pentane (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce heksanu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce heptanu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce oktanu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Gas chromatography with flame ionization detection (GC - FID) PN-EN 13649:2005
121 Waste gases Sum of aromatic hydrocarbons: benzene, toluene, ethylbenzene, xylenes (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 13649:2005
122 Waste gases Emission of individual gaseous organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 13649:2005
123 Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 14385:2025-05
124 Waste gases Stężenie/ zawartość metali
Antimony (0,023 – 1,0) mg/m3 Range (0,025 – 2,0) mg w próbce arsenic (0,023 – 1,0) mg/m3 (0,025 – 2,0) mg w próbce chrom (0,0023 – 1,0) mg/m3 (0,0025 – 2,5) mg w próbce kadm (0,00093 – 1,00) mg/m3 (0,001 – 2,0) mg w próbce kobalt (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg w próbce mangan (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg w próbce miedź (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg w próbce nikiel (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg w próbce ołów (0,0046 – 1,0) mg/m3 (0,005 – 2,0) mg w próbce tal (0,023 – 1,0) mg/m3 (0,025 – 2,0) mg w próbce wanad (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg w próbce
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 14385:2025-05
125 Waste gases Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 14385:2025-05
126 Waste gases Sampling for determination of styrene concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-93/Z-04152/06
127 Waste gases Concentration/ content of styrene
Range (0,5 – 1900) mg/m3 Range (0,005 – 19) mg w próbce
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC FID) PN-93/Z-04152/06
128 Waste gases Emission of styrene (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-93/Z-04152/06
129 Waste gases Sampling for determination of tetrachloroethene concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 13649:2005
130 Waste gases Concentration/ content of tetrachloroethene
Range (0,5 – 1900) mg/m3 Range (0,005 –19) mg w próbce
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
131 Waste gases Emission of tetrachloroethene (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 13649:2005
132 Waste gases Pobieranie próbek do oznaczania stężenia węglowodorów alifatycznych suma C5 – C12
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 13649:2005
133 Waste gases Stężenie/ zawartość węglowodorów alifatycznych suma C5 – C12
Range (0,5 – 1900) mg/m3 Range (0,005 – 19) mg w próbce
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
134 Waste gases Emisja węglowodorów alifatycznych suma C5 – C12 (z obliczeń)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 13649:2005
135 Waste gases Sampling for determination of total mercury concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 13211+AC:2006
136 Waste gases Total mercury emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 13211+AC:2006
137 Waste gases Sampling for determination of hydrogen chloride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 1911:2011
138 Waste gases Hydrogen chloride emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 1911:2011
139 Waste gases Sampling for determination of the concentration of gaseous fluorides
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
ISO 15713:2006
140 Waste gases Emission of gaseous fluorides (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
ISO 15713:2006
141 Automated Measuring Systems (AMS) Kalibracja AMS (QAL2) w zakresie: pyłu, O2, CO2, CO, NOx, NO, SO2
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 14181:2015
142 Automated Measuring Systems (AMS) Roczne badanie kontrolne (AST) w zakresie: pyłu, O2, CO2, CO, NOx, NO, SO2
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
PN-EN 14181:2015
143 Automated Measuring Systems (AMS) Dust concentration
Range (0,001 – 10 ) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Gravimetric method PN-Z-04030-7:1994
144 Automated Measuring Systems (AMS) Dust concentration
Range (1 – 50) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Gravimetric method PN-EN 13284-1:2018-02
145 Automated Measuring Systems (AMS) Oxygen concentration
Range (3,0 – 21,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Paramagnetic method PN-EN 14789:2017-04
146 Automated Measuring Systems (AMS) CO2 concentration
Range (0,1 – 20,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) PN-ISO 10396:2001
147 Automated Measuring Systems (AMS) CO concentration
Range (2,0 – 1400) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) PN-EN 15058:2017-04
148 Automated Measuring Systems (AMS) NO, NOx concentration
NO (1,3 – 435) mg/m3 NOx (2,0 – 700) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Chemiluminescence method (CLD) PN-EN 14792:2017-04
149 Automated Measuring Systems (AMS) SO2 concentration
Range (5 – 2000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Thoron method PN-EN 14791:2017-04
150 Automated Measuring Systems (AMS) Water vapour concentration (H2O)
Range (4,0 – 40) % Range (29 – 250) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Metoda kondensacyjno - absorpcyjna PN-EN 14790:2017-04
151 Waste gases Dust sampling for determination of the fraction composition PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02
152 Waste gases Emission of the dust fraction (calculated) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02
153 Waste gases Sampling for determination of formaldehyde concentration Aspiration method using absorbing solutions Procedura Badawcza PB-14 wydanie 10 z dnia 18.09.2019 r.
154 Waste gases Concentration/ content of formaldehyde
Range (0,2 – 100) mg/m3 Range (0,0005 – 0,02) mg w próbce
Spectrophotometric method Procedura Badawcza PB-14 wydanie 10 z dnia 18.09.2019 r.
155 Waste gases Formaldehyde emission (calculated) Procedura Badawcza PB-14 wydanie 10 z dnia 18.09.2019 r.
156 Waste gases Sampling for determination of phenol concentration Aspiration method using absorbing solutions Procedura Badawcza PB-13 wydanie 10 z dnia 18.09.2019 r.
157 Waste gases Concentration/ content of phenol
Range (0,1 – 100) mg/m3 Range (0,005 – 19) mg w próbce
Spectrophotometric method Procedura Badawcza PB-13 wydanie 10 z dnia 18.09.2019 r.
158 Waste gases Phenol emission (calculated) Procedura Badawcza PB-13 wydanie 10 z dnia 18.09.2019 r.
159 Waste gases Sampling for determination of ammonia concentration Aspiration method using absorbing solutions PN-EN ISO 21877:2020-03
160 Waste gases Ammonia concentration/ content
Range (0,17 – 100) mg/m3 Range (0,005 – 2) mg w próbce
Spectrophotometric method PN-EN ISO 21877:2020-03
161 Waste gases Ammonia emission (calculated) PN-EN ISO 21877:2020-03
162 Waste gases Sampling for determination of metal concentrations: Fe, Zn PN-EN 14385:2025-05
163 Waste gases Emission of metals: Fe, Zn (calculated) PN-EN 14385:2025-05
164 Waste gases Stężenie/ zawartość metali
zinc (0,0046 – 5,0) mg/m3 Range (0,005 – 10,0) mg w próbce iron (0,023 – 5,00) mg/m3 (0,025 – 10,0) mg w próbce
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB 58 wydanie 1 z dnia 16.04.2021 r.
165 Waste gases Sampling for determination of formaldehyde concentration Procedura Badawcza PB 52 wydanie 3 z dnia 28.08.2019 r.
166 Waste gases Concentration/ content of formaldehyde
Range (0,08 – 60) mg/m3 Range (0,0008 – 0,06) mg w próbce
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Procedura Badawcza PB 52 wydanie 3 z dnia 28.08.2019 r.
167 Waste gases Formaldehyde emission (calculated) Procedura Badawcza PB 52 wydanie 3 z dnia 28.08.2019 r.
168 Waste gases Pobieranie próbek do oznaczania stężenia akrylaldehydu Procedura Badawcza PB 54 wydanie 1 z dnia 15.05.2020 r.
169 Waste gases Stężenie/ zawartość akrylaldehydu
Range (0,012 – 60) mg/m3 Range (0,00012 – 0,060) mg w próbce
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Procedura Badawcza PB 54 wydanie 1 z dnia 15.05.2020 r.
170 Waste gases Emisja akrylaldehydu (z obliczeń) Procedura Badawcza PB 54 wydanie 1 z dnia 15.05.2020 r.
171 Dust samples Zawartość frakcji pyłu (składu ziarnowego), w tym PM2,5 i PM10
Range (0,6 – 1200) μm Range (0 – 100) %
Metoda elektrycznej strefy wykrywania ISO 13319-1:2021
172 Water, wastewater Indeks oleju mineralnego (węglowodory ropopochodne C10-C40)
Range (0,80 – 44,0) mg/l
Gas chromatography with flame ionization detection (GC - FID) PN-EN ISO 9377-2:2003
173 Water, wastewater pH
range (2,0 – 10,0)
Potentiometric method PN-EN ISO 10523:2012
174 Water, wastewater Electrical conductivity
Range (147 – 1600) μS/cm
Conductometric method PN-EN 27888:1999
175 Water, wastewater Chemical oxygen demand
COD-Cr Range (10,0 – 2 000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
176 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,50 – 6,0) mg/l O2
Titrimetric method; Electrochemical method PN-EN 1899-2:2002
177 Water, wastewater Biochemical oxygen demand
BOD5 Range (3,0 – 2000) mg/l O2
Titrimetric method; Electrochemical method PN-EN ISO 5815-1:2019-12
178 Water, wastewater Total phosphorus concentration
Range (0,050 – 40,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt.8 +Ap1:2010 + Ap2:2010
179 Water, wastewater Phosphate concentration
Range (0,050 – 40,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt.4 +Ap1:2010 + Ap2:2010
180 Water, wastewater Total suspended solids (TSS)
Range (5,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007 + Ap1:2007
181 Water, wastewater Metal concentrations
zinc (0,005 – 10) mg/l cadmium (0,010 – 10) mg/l copper (0,025 – 25) mg/l nickel (0,025 – 25) mg/l lead (0,05 – 50) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 metoda A IR-106 wydanie 1 z dnia 05.11.2018 r. pkt.3.1.4
182 Water, wastewater Iron concentration
Range (0,05 – 50) mg/l
Flame atomic absorption spectrometry (FAAS) Procedura Badawcza PB-37 wydanie 5 z dnia 24.06.2019 r.
183 Water, wastewater Total chromium concentration
Range (0,05 – 8,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-EN 1233:2000 pkt.3
184 Water, wastewater Sulfate concentration
Range (10 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
185 Water, wastewater Ammonium nitrogen concentration
Range (0,10 – 160) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
186 Water, wastewater Nitrite nitrogen concentration
Range (0,030 – 10) mg/l Nitrite concentration Range (0,098 – 33) mg/l
Spectrophotometric method PN-EN 26777:1999
187 Water, wastewater Nitrate nitrogen concentration
Range (0,40 – 100) mg/l Nitrate concentration Range (1,77 – 443) mg/l
Spectrophotometric method PN-82/C-04576/08
188 Water, wastewater Dissolved solids concentration
Range (10,0 – 2500) mg/l
Gravimetric method Procedura Badawcza PB-23 wydanie 7 z dnia 24.06.2019 r.
189 Water, wastewater Metal concentrations
chromium (0,0125 – 5,0) mg/l zinc (0,25 – 10) mg/l aluminium (0,050 – 10) mg/l cadmium (0,0050 – 1,0) mg/l manganese (0,025 – 5,0) mg/l copper (0,0125 – 5,0) mg/l nickel (0,0125 – 5,0) mg/l lead (0,025 – 5,0) mg/l iron (0,050 – 10) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
190 Wastewater Sampling for chemical testing and physical properties
Temperature Range (0,0 – 50,0) oC
Manual method PN-ISO 5667-10:2021-11 Procedura Badawcza PB-20 wydanie 8 z dnia 01.03.2022 r.
191 Wastewater Kjeldahl nitrogen concentration
Range (3,0 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
192 Wastewater Total nitrogen concentration (calculated) Procedura Badawcza PB–22 wydanie 6 z dnia 24.06.2019 r.
193 Wastewater Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
194 Water Chloride concentration
Range (5,0 – 400) mg/l
Titrimetric method PN-ISO 9297:1994
195 Soil pH - in KCl
Range (2,0 – 10,0)
Potentiometric method PN-EN ISO 10390:2022-09
196 Soil Dry matter content
Range (50,0 – 99,0) %
Gravimetric method PN-ISO 11465:2026-03
197 Soil Water content
Range (1,0 – 50,0) %
Gravimetric method PN-ISO 11465:2026-03
198 Soil, ground Sampling for physical and chemical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009
199 Soil, ground Metal content
arsenic (8,3 – 500) mg/kg barium (16,7 – 5000) mg/kg chromium (3,3 – 2000) mg/kg tin (8,3 – 500) mg/kg zinc (3,3 – 5000) mg/kg cadmium (0,83 – 50) mg/kg cobalt (1,7 – 500) mg/kg copper (3,3 – 2000) mg/kg molybdenum (3,3 – 500) mg/kg nickel (3,3 – 1000) mg/kg lead (8,3 – 1000) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-ISO 11466:2002 | PN-EN ISO 11885:2009
200 Soil, ground Mercury concentration and content
Range (0,20 – 100) mg/kg
Cold vapour atomic absorption spectrometry (CVAAS) PN-ISO 16772:2009
201 Soil, ground Suma węglowodorów C6 - C12 (składników frakcji benzyn)
Range (1,0 – 1000) mg/kg
Headspace gas chromatography with flame ionization detection (HS-GC-FID) Procedura Badawcza PB-59 wydanie 1 z dnia 01.03.2022 r.
202 Soil, ground Suma węglowodorów C12 – C35 (składników frakcji oleju)
Range (30 – 5000) mg/kg
Gas chromatography with flame ionization detection (GC-FID) Procedura Badawcza PB-60 wydanie 1 z dnia 01.03.2022 r.
203 Soil, ground Aromatic hydrocarbon content
benzene (0,10 – 250) mg/kg ethylbenzene (0,10 – 250) mg/kg toluene (0,10 – 250) mg/kg ksyleny (m,p,o) (0,10 – 250) mg/kg styrene (0,10 – 250) mg/kg
Headspace gas chromatography with flame ionization detection (HS-GC-FID) PN-EN ISO 22155:2016-07
204 Soil, ground Content of polycyclic aromatic hydrocarbons PAH
naphthalene (0,020 – 100) mg/kg anthracene (0,020 – 100) mg/kg chrysene (0,020 – 100) mg/kg benzo(a)anthracene Range (0,020 – 100) mg/kg dibenzo(ah)anthracene (0,020 – 100) mg/kg benzo(a)pyrene (0,020 – 100) mg/kg benzo(b)fluoranthene (0,020 – 100) mg/kg benzo(k)fluoranthene (0,020 – 100) mg/kg benzo(ghi)perylene (0,020 – 100) mg/kg indeno (1,2,3,c,d)piren (0,020 – 100) mg/kg
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-ISO 13877:2004
205 WasteO) code: 10 01 01 20 01 99
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Moisture content
Range (0,20 – 42,0) %
Gravimetric method PN-93/Z-15008/02
206 WasteO) code: 10 01 01 20 01 99
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Combustible matter content
Range (1,00 – 80,00) %
Gravimetric method PN-93/Z-15008/03
207 WasteO) code: 10 01 01 20 01 99
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Content of non-combustible parts (calculated) PN-93/Z-15008/03
208 WasteO) code: 10 01 01 20 01 99
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Metal content
Al (10000 – 1000000) mg/kg Cd (4 – 10000) mg/kg Co (40 – 10000) mg/kg Cr (50 – 100000) mg/kg Cu (140 – 1000000) mg/kg Fe (5000 – 1000000) mg/kg Mn (200 – 100000) mg/kg Ni (75 – 100000) mg/kg Pb (40 – 10000) mg/kg Ti (5000 – 100000) mg/kg Zn (150 – 1000000) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedura Badawcza PB–53 wydanie 2 z dnia 07.07.2020 r.
209 Heating boilers for solid fuels with manual and automatic fuel feeding Moc cieplna
Range (0 – 500) kW Temperatura wody wylotowej Temperatura wody na powrocie Temperatura otoczenia Range (10 – 100 ) °C Strumień objętości wody Range (0,1 – 20,0 m3/h) Strumień masy paliwa Range (0,5 – 100 kg/h) Temperatura spalin wylotowych Range ( 50 – 300 ) °C Ciśnienie spalin Range ( -150 – 50 ) hPa
Metoda bezpośrednia; Metoda rezystancyjna; Metoda ultradźwiękowa; Metoda wagowa; Metoda rezystancyjna; Metoda piezorezystancyjna PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5:2021-09 p. 5.7 | PN-EN 303-5:2021-09 p. 5.8 | PN-EN 303-5 +A1:2023-05 p. 5.2 | PN-EN 303-5 +A1:2023-05 p. 5.7 | PN-EN 303-5 +A1:2023-05 p. 5.8 | EN 303-5:2021+A1:2022 p. 5.2 | EN 303-5:2021+A1:2022 p. 5.7 | EN 303-5:2021+A1:2022 p. 5.8
210 Heating boilers for solid fuels with manual and automatic fuel feeding Stężenie tlenu, ditlenku węgla, tlenku węgla, tlenków azotu, ditlenku siarki, lotnych związków organicznych
O2 (1 – 21) % CO2 (0,1 – 20) % CO (3 – 1400) mg/m3 SO2 (19 – 3000) mg/m3 NO (9,0 – 435) mg/m3 NOX (14,0 – 700) mg/m3 OGC (1,8 – 1000) mg/m3 Stężenie pyłów w gazach spalinowych Range (1,0 – 100) mg/m3
Metoda elektrochemiczna - O2 (3,0 – 21,0) %; Metoda paramagnetyczna; Metoda NDIR; Metoda chemiluminescencji; Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID); Metoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5:2021-09 p. 5.7 | PN-EN 303-5:2021-09 p. 5.8 | PN-EN 303-5 +A1:2023-05 p. 5.2 | PN-EN 303-5 +A1:2023-05 p. 5.7 | PN-EN 303-5 +A1:2023-05 p. 5.8 | EN 303-5:2021+A1:2022 p. 5.2 | EN 303-5:2021+A1:2022 p. 5.7 | EN 303-5:2021+A1:2022 p. 5.8
211 Heating boilers for solid fuels with manual and automatic fuel feeding Emisja tlenu, ditlenku węgla, tlenku węgla, tlenków azotu, ditlenku siarki, lotnych związków organicznych
O2 (1– 21) % CO2 (0,1 – 20) % CO (3 – 1400) mg/m3 SO2 (19 – 3000) mg/m3 NO (9,0 – 435) mg/m3 NOX (14,0 – 700) mg/m3 OGC (1,8 – 1000) mg/m3 Stężenie pyłów w gazach spalinowych Range (1,0 – 100) mg/m3
Metoda elektrochemiczna - O2 (3,0 – 21,0) %; Metoda paramagnetyczna; Metoda NDIR; Metoda chemiluminescencji; Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID); Metoda grawimetryczna PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5:2021-09 p. 5.8 | PN-EN 303-5:2021-09 p. 5.9.4 | PN-EN 303-5 +A1:2023-05 p. 5.2 | PN-EN 303-5 +A1:2023-05 p. 5.8 | PN-EN 303-5 +A1:2023-05 p. 5.9.4 | EN 303-5:2021+A1:2022 p. 5.2 | EN 303-5:2021+A1:2022 p. 5.8 | EN 303-5:2021+A1:2022 p. 5.9.4
212 Heating boilers for solid fuels with manual and automatic fuel feeding Nominalna moc cieplna
Range (0 – 500) kW
Direct method PN-EN 303-5:2021-09 p. 5.7.2 | PN-EN 303-5 +A1:2023-05 p. 5.7.2 | EN 303-5:2021+A1:2022 p. 5.7.2
213 Heating boilers for solid fuels with manual and automatic fuel feeding Minimalna moc cieplna
Range (0 – 500) kW
Direct method PN-EN 303-5:2021-09 p. 5.7.3 | PN-EN 303-5 +A1:2023-05 p. 5.7.3 | EN 303-5:2021+A1:2022 p. 5.7.3
214 Heating boilers for solid fuels with manual and automatic fuel feeding Sprawność cieplna Metoda bezpośrednia (z obliczeń) PN-EN 303-5:2021-09 p. 5.7.6 | PN-EN 303-5:2021-09 p. 5.9.3.2 | PN-EN 303-5 +A1:2023-05 p. 5.7.6 | PN-EN 303-5 +A1:2023-05 p. 5.9.3.2 | EN 303-5:2021+A1:2022 p. 5.7.6 | EN 303-5:2021+A1:2022 p. 5.9.3.2
215 Heating boilers for solid fuels with manual and automatic fuel feeding Sprawność cieplna Metoda pośrednia (z obliczeń) PN-EN 303-5:2021-09 p. 5.9.3.3 | PN-EN 303-5 +A1:2023-05 p. 5.9.3.3 | EN 303-5:2021+A1:2022 p. 5.9.3.3
216 Heating boilers for solid fuels with manual and automatic fuel feeding Zużycie pomocniczej energii elektrycznej
Range (1 – 4000) W
Metoda: przetwornik mocy PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5 +A1:2023-05 p. 5.7.7 | EN 303-5:2021+A1:2022 p. 5.7.7
217 Heating boilers for solid fuels with manual and automatic fuel feeding Useful efficiency nGCV (calculated) PN-EN 303-5:2021-09 p. 5.9.3.4 | PN-EN 303-5 +A1:2023-05 p. 5.9.3.4 | EN 303-5:2021+A1:2022 p. 5.9.3.4
218 Heating boilers for solid fuels with manual and automatic fuel feeding Seasonal space heating energy efficiency ns (calculated) PN-EN 303-5:2021-09 p. 5.9.3.5 | PN-EN 303-5 +A1:2023-05 p. 5.9.3.5 | EN 303-5:2021+A1:2022 p. 5.9.3.5
219 Heating boilers for solid fuels with manual and automatic fuel feeding Energy efficiency index EEI (calculated) PN-EN 303-5:2021-09 p. 5.9.3.6 | PN-EN 303-5 +A1:2023-05 p. 5.9.3.6 | EN 303-5:2021+A1:2022 p. 5.9.3.6
220 Heating boilers for solid fuels with manual and automatic fuel feeding Seasonal space heating emissions Es (calculated) PN-EN 303-5:2021-09 p. 5.9.4.4 | PN-EN 303-5 +A1:2023-05 p. 5.9.4.4 | EN 303-5:2021+A1:2022 p. 5.9.4.4
221 Heating boilers for solid fuels with manual and automatic fuel feeding Surface temperature
Range (15 – 150) °C
Metoda rezystancyjna PN-EN 303-5:2021-09 p. 5.11 | PN-EN 303-5 +A1:2023-05 p. 5.11 | EN 303-5:2021+A1:2022 p. 5.11
222 Heating boilers for solid fuels with manual and automatic fuel feeding Temperatura uchwytów
Range (0 – 150) °C
Metoda rezystancyjna PN-EN 303-5:2021-09 p. 5.11 | PN-EN 303-5 +A1:2023-05 p. 5.11 | EN 303-5:2021+A1:2022 p. 5.11
223 Heating boilers for solid fuels with manual and automatic fuel feeding Działanie regulatora temperatury
temperatura wody wylotowej Range (60 – 110) °C
Metoda rezystancyjna PN-EN 303-5:2021-09 p. 5.13 | PN-EN 303-5 +A1:2023-05 p. 5.13 | EN 303-5:2021+A1:2022 p. 5.13
224 Heating boilers for solid fuels with manual and automatic fuel feeding Działanie ogranicznika temperatury bezpieczeństwa
temperatura wody wylotowej Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) %
Metoda rezystancyjna; Metoda NDIR PN-EN 303-5:2021-09 p. 5.13 | PN-EN 303-5 +A1:2023-05 p. 5.13 | EN 303-5:2021+A1:2022 p. 5.13
225 Heating boilers for solid fuels with manual and automatic fuel feeding Działanie systemów szybkowyłączalnych:
zanik napięcia awaria odbioru ciepła temperatura wody wylotowej Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) %
Metoda rezystancyjna; Metoda NDIR PN-EN 303-5:2021-09 p. 5.14 | PN-EN 303-5 +A1:2023-05 p. 5.14 | EN 303-5:2021+A1:2022 p. 5.14
226 Heating boilers for solid fuels with manual and automatic fuel feeding Badanie w warunkach przy zablokowaniu zasilania paliwem
temperatura wody wylotowej Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) %
Metoda rezystancyjna; Metoda NDIR PN-EN 303-5:2021-09 p. 5.16.2 | PN-EN 303-5 +A1:2023-05 p. 5.16.2 | EN 303-5:2021+A1:2022 p. 5.16.2
227 Heating boilers for solid fuels with manual and automatic fuel feeding Badanie bezpieczeństwa przy zaniku dopływu powietrza. Awaria wentylatora powietrza, awaria układu doprowadzania powietrza
Carbon monoxide content CO (0,4 – 5,0) %
NDIR method PN-EN 303-5:2021-09 p. 5.16.3 | PN-EN 303-5 +A1:2023-05 p. 5.16.3 | EN 303-5:2021+A1:2022 p. 5.16.3
228 Heating boilers for solid fuels with manual and automatic fuel feeding Badanie bezpieczeństwa w zakresie przewodzenia ciepła
temperature Range (15 – 150) °C
Metoda rezystancyjna PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4 | EN 303-5:2021+A1:2022 p. 5.16.4

Reference standards (179)

EN 303-5:2021+A1:2022 p. 5.11
EN 303-5:2021+A1:2022 p. 5.13
EN 303-5:2021+A1:2022 p. 5.14
EN 303-5:2021+A1:2022 p. 5.16.2
EN 303-5:2021+A1:2022 p. 5.16.3
EN 303-5:2021+A1:2022 p. 5.16.4
EN 303-5:2021+A1:2022 p. 5.2
EN 303-5:2021+A1:2022 p. 5.7
EN 303-5:2021+A1:2022 p. 5.7.2
EN 303-5:2021+A1:2022 p. 5.7.3
EN 303-5:2021+A1:2022 p. 5.7.6
EN 303-5:2021+A1:2022 p. 5.7.7
EN 303-5:2021+A1:2022 p. 5.8
EN 303-5:2021+A1:2022 p. 5.9.3.2
EN 303-5:2021+A1:2022 p. 5.9.3.3
EN 303-5:2021+A1:2022 p. 5.9.3.4
EN 303-5:2021+A1:2022 p. 5.9.3.5
EN 303-5:2021+A1:2022 p. 5.9.3.6
EN 303-5:2021+A1:2022 p. 5.9.4
EN 303-5:2021+A1:2022 p. 5.9.4.4
ISO 13319-1:2021
ISO 15713:2006
NIOSH 7907 Method, Issue 1, 20 May 2014
OSHA Method 1008
OSHA Method 1011
OSHA Method 182
OSHA Method 190
PN-71/Z-04041
PN-79/Z-04081/01
PN-79/Z-04107/02
PN-81/Z 04134/02
PN-81/Z-04134/03
PN-82/C-04576/08
PN-83/E-04040.03
PN-83/Z-04118/02
PN-84/Z 04135/02
PN-84/Z 04138/02
PN-86/Z 04166/02
PN-86/Z-04152/02
PN-87/Z-04100.03
PN-89/Z-04023/02
PN-93/Z-04152/06
PN-93/Z-15008/02
PN-93/Z-15008/03
PN-EN 1233:2000 pkt.3
PN-EN 12619:2013-05
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14181:2015
PN-EN 14253+A1:2011
PN-EN 14385:2025-05
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
PN-EN 1899-2:2002
PN-EN 1911:2011
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 303-5 +A1:2023-05 p. 5.11
PN-EN 303-5 +A1:2023-05 p. 5.13
PN-EN 303-5 +A1:2023-05 p. 5.14
PN-EN 303-5 +A1:2023-05 p. 5.16.2
PN-EN 303-5 +A1:2023-05 p. 5.16.3
PN-EN 303-5 +A1:2023-05 p. 5.16.4
PN-EN 303-5 +A1:2023-05 p. 5.2
PN-EN 303-5 +A1:2023-05 p. 5.7
PN-EN 303-5 +A1:2023-05 p. 5.7.2
PN-EN 303-5 +A1:2023-05 p. 5.7.3
PN-EN 303-5 +A1:2023-05 p. 5.7.6
PN-EN 303-5 +A1:2023-05 p. 5.7.7
PN-EN 303-5 +A1:2023-05 p. 5.8
PN-EN 303-5 +A1:2023-05 p. 5.9.3.2
PN-EN 303-5 +A1:2023-05 p. 5.9.3.3
PN-EN 303-5 +A1:2023-05 p. 5.9.3.4
PN-EN 303-5 +A1:2023-05 p. 5.9.3.5
PN-EN 303-5 +A1:2023-05 p. 5.9.3.6
PN-EN 303-5 +A1:2023-05 p. 5.9.4
PN-EN 303-5 +A1:2023-05 p. 5.9.4.4
PN-EN 303-5:2021-09 p. 5.11
PN-EN 303-5:2021-09 p. 5.13
PN-EN 303-5:2021-09 p. 5.14
PN-EN 303-5:2021-09 p. 5.16.2
PN-EN 303-5:2021-09 p. 5.16.3
PN-EN 303-5:2021-09 p. 5.16.4
PN-EN 303-5:2021-09 p. 5.2
PN-EN 303-5:2021-09 p. 5.7
PN-EN 303-5:2021-09 p. 5.7.2
PN-EN 303-5:2021-09 p. 5.7.3
PN-EN 303-5:2021-09 p. 5.7.6
PN-EN 303-5:2021-09 p. 5.7.7
PN-EN 303-5:2021-09 p. 5.8
PN-EN 303-5:2021-09 p. 5.9.3.2
PN-EN 303-5:2021-09 p. 5.9.3.3
PN-EN 303-5:2021-09 p. 5.9.3.4
PN-EN 303-5:2021-09 p. 5.9.3.5
PN-EN 303-5:2021-09 p. 5.9.3.6
PN-EN 303-5:2021-09 p. 5.9.4
PN-EN 303-5:2021-09 p. 5.9.4.4
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11079:2008
PN-EN ISO 11885:2009
PN-EN ISO 21877:2020-03
PN-EN ISO 22155:2016-07
PN-EN ISO 3746:2011 z wyłączeniem punktu 8.4
PN-EN ISO 3746:2011/Ap1:2017-09
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004+A1:2015-11
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 pkt.4 +Ap1:2010 + Ap2:2010
PN-EN ISO 6878:2006 pkt.8 +Ap1:2010 + Ap2:2010
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9377-2:2003
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 10396:2001
PN-ISO 11465:2026-03
PN-ISO 11466:2002
PN-ISO 13877:2004
PN-ISO 15705:2005
PN-ISO 16772:2009
PN-ISO 5667-10:2021-11 Procedura Badawcza PB-20 wydanie 8 z dnia 01.03.2022 r.
PN-ISO 7150-1:2002
PN-ISO 8288:2002 metoda A IR-106 wydanie 1 z dnia 05.11.2018 r. pkt.3.1.4
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04016-10:2005
PN-Z-04030-7:1994
PN-Z-04045-16:2010
PN-Z-04106-3:2002
PN-Z-04108-5:2006
PN-Z-04136-3:2003
PN-Z-04263-1:2012
PN-Z-04323:2004
PN-Z-04354:2005
PN-Z-04434:2011
PN-Z-04469:2015-10
PN-Z-04472:2015-10+Ap1:2015-12
PN-Z-04476:2016-10
PN-Z-04487:2017-10
PN-Z-04502:2019-10
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, str. 91-95
Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, str. 96-100
Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130
Podstawy i Metody Oceny Środowiska Pracy 2017 nr 2(92), str. 5-19
Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103), str. 157-170
Procedura Badawcza PB 52 wydanie 3 z dnia 28.08.2019 r.
Procedura Badawcza PB 54 wydanie 1 z dnia 15.05.2020 r.
Procedura Badawcza PB 58 wydanie 1 z dnia 16.04.2021 r.
Procedura Badawcza PB-01 wydanie 8 z dnia 24.06.2019 r.
Procedura Badawcza PB-13 wydanie 10 z dnia 18.09.2019 r.
Procedura Badawcza PB-14 wydanie 10 z dnia 18.09.2019 r.
Procedura Badawcza PB-23 wydanie 7 z dnia 24.06.2019 r.
Procedura Badawcza PB-37 wydanie 5 z dnia 24.06.2019 r.
Procedura Badawcza PB-51 wydanie 5 z dnia 10.06.2025 r.
Procedura Badawcza PB-55 wydanie 1 z dnia 10.09.2020 r.
Procedura Badawcza PB-57 wydanie 1 z dnia 16.04 2021 r.
Procedura Badawcza PB-59 wydanie 1 z dnia 01.03.2022 r.
Procedura Badawcza PB-60 wydanie 1 z dnia 01.03.2022 r.
Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
Procedura Badawcza PB–22 wydanie 6 z dnia 24.06.2019 r.
Procedura Badawcza PB–53 wydanie 2 z dnia 07.07.2020 r.
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F