🇵🇱 CENTRUM BADAŃ ŚRODOWISKA „SORBCHEM” Sp. z o.o. PL
EnvironmentWater & wastewaterPetrochemistry & fuelsMaterials & polymers
CENTRUM BADAŃ ŚRODOWISKA „SORBCHEM” Sp. z o.o. is a laboratory accredited by PCA under number AB 1302 (Ruda Śląska, Poland). Its accreditation scope covers 228 test methods in the following areas: Environment, Water & wastewater, Petrochemistry & fuels, Materials & polymers. Test objects include: Workplace environment - air, Waste gases, Heating boilers for solid fuels with manual and automatic fuel feeding, Water, wastewater. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Inductively coupled plasma optical emission spectrometry (ICP-OES), Flame atomic absorption spectrometry (FAAS).
At a glance
- Accreditation number: PCA AB 1302
- Methods in scope: 228
- Types of test objects: 23
- Techniques used: 42
- City: Ruda Śląska, Poland
- Accreditation number
- AB 1302
- Accreditation body
- PCA
- Address
- LABORATORIUM, ul. Kokotek 6, 41-700 Ruda Śląska
- City
- Ruda Śląska, Poland
What this laboratory tests (23)
- Workplace environment - air — 73 methods
- Waste gases — 63 methods
- Heating boilers for solid fuels with manual and automatic fuel feeding — 20 methods
- Water, wastewater — 18 methods
- Automated Measuring Systems (AMS) — 10 methods
- Soil, ground — 7 methods
- O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów — 4 methods
- WasteO) code: 10 01 01 20 01 99 — 4 methods
- Wastewater — 4 methods
- Workplace environment − emergency lighting — 4 methods
- Soil — 3 methods
- General environment − noise from installations, equipment and industrial plants — 2 methods
- Machinery and equipment - noise — 2 methods
- Workplace environment - electric lighting — 2 methods
- Workplace environment - noise — 2 methods
- and 8 more
Analytical techniques used (42)
- Gas chromatography with flame ionization detection (GC-FID) — 26 methods
- Inductively coupled plasma optical emission spectrometry (ICP-OES) — 24 methods
- Flame atomic absorption spectrometry (FAAS) — 13 methods
- Gravimetric method — 13 methods
- Direct measurement method — 12 methods
- Spectrophotometric method — 11 methods
- Ion chromatography with conductometric detection (IC-CD) — 7 methods
- High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) — 4 methods
- Metoda rezystancyjna — 4 methods
- Aspiration method using absorbing solutions — 3 methods
- Gas chromatography with flame ionization detection (GC - FID) — 3 methods
- Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) — 3 methods
- Metoda rezystancyjna; Metoda NDIR — 3 methods
- Titrimetric method — 3 methods
- Chemiluminescence method (CLD) — 2 methods
- and 27 more
Accreditation scope — test methods (228)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (26 – 135) dB C-weighted peak sound pressure level Range (40 – 138) dB |
Direct measurement method | PN-N-01307:1994 | PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 | |
| 2 | Workplace environment - noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 | ||
| 3 | Workplace environment − emergency lighting | Illuminance Range (0,5 – 200) lx |
Direct measurement method | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5. | |
| 4 | Workplace environment − emergency lighting | Ratio of minimum to maximum illuminance (calculated) | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5. | ||
| 5 | Workplace environment − emergency lighting | Illuminance uniformity for the high-risk zone (calculated) | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5. | ||
| 6 | Workplace environment − emergency lighting | Closing time Range (3-90) s |
Direct measurement method | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5. | |
| 7 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (26 – 135) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | |
| 8 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | ||
| 9 | Machinery and equipment - noise | Sound pressure level weighted with the characteristic frequency weighting A Range (26 − 135) dB |
Direct measurement method | PN-EN ISO 3746:2011 z wyłączeniem punktu 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 | |
| 10 | Machinery and equipment - noise | Sound power level (calculated) | PN-EN ISO 3746:2011 z wyłączeniem punktu 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 | ||
| 11 | Workplace environment - electric lighting | Illuminance Range (5 – 5000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 12 | Workplace environment - electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 13 | Workplace environment – energy expenditure | Air temperature Range (0 – 40) °C Air flow Range (10 - 60) dm3/min |
Direct measurement method | Procedura Badawcza PB-51 wydanie 5 z dnia 10.06.2025 r. | |
| 14 | Workplace environment – energy expenditure | Energy expenditure (calculated) | Procedura Badawcza PB-51 wydanie 5 z dnia 10.06.2025 r. | ||
| 15 | Workplace environment − moderate microclimate | Air temperature Range (10,0 – 30,0) 0C Black globe temperature Range (10,0 – 40,0) 0C Air humidity Range (20,0 – 90,0) % Air velocity Range (0,15 – 4,0) m/s |
Direct measurement method | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | |
| 16 | Workplace environment − moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | ||
| 17 | Workplace environment − hot microclimate | Air temperature Range (15,0 – 60,0) 0C Natural wet bulb temperature Range (15,0 – 60,0) 0C Black globe temperature Range (15,0 – 40,0) 0C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 18 | Workplace environment − hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 19 | Workplace environment − cold microclimate | Air temperature Range (-10,0 – 10,0) 0C Black globe temperature Range (-10,0 – 15,0) 0C Air humidity Range (20,0 – 90,0) % Air velocity Range (0,4 – 4,0) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 20 | Workplace environment − cold microclimate | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 21 | Workplace environment – hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,02 – 100) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 | |
| 22 | Workplace environment – hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 | ||
| 23 | Workplace environment – whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,02 – 100) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 24 | Workplace environment – whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 25 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 26 | Workplace environment - air | Sampling for occupational exposure assessment to inorganic substances | Stationary method | PN-Z-04008-7:2002+Az1:2004 | |
| 27 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 28 | Workplace environment - air | Concentration of harmful dust agents - inhalable fraction Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,19 – 20,4) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 29 | Workplace environment - air | Concentration of dust agents harmful to health- respirable fraction Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,10 – 6,2) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 30 | Workplace environment - air | Carbon monoxide concentration Range (2,3 – 234) mg/m3 Range (2,0 – 201) ppm |
Electrochemical method | Procedura Badawcza PB-01 wydanie 8 z dnia 24.06.2019 r. | |
| 31 | Workplace environment - air | Exposure indices (calculated) | Procedura Badawcza PB-01 wydanie 8 z dnia 24.06.2019 r. | ||
| 32 | Workplace environment - air | Crystalline silica (quartz, cristobalite) concentration/content respirable fraction Range (0,010 – 0,4) mg/m3 Range (10,0 – 400) μg w próbce |
Fourier transform infrared spectrometry (FT-IR) | Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130 | |
| 33 | Workplace environment - air | Ammonia concentration/ content Range (1 – 100) mg/m3 Range (0,015 – 1,5) mg w próbce |
Spectrophotometric method | PN-71/Z-04041 | |
| 34 | Workplace environment - air | Stężenie/ zawartość tlenku azotu i ditlenku azotu NO (0,09 – 10,4) mg/m3 Range (0,072 – 8,4) ppm Range (0,00045 – 0,052) mg w próbce NO2 (0,07 – 8,0) mg/m3 (0,037 – 4,2) ppm (0,00035 – 0,040) mg w próbce |
Spectrophotometric method | PN-Z-04009-11:2008 | |
| 35 | Workplace environment - air | Concentration/ content of formaldehyde Range (0,033 – 2,50) mg/m3 Range (0,0008 – 0,060) mg w próbce |
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) | Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, str. 96-100 | |
| 36 | Workplace environment - air | Stężenie/ zawartość akrylaldehydu Range (0,005 – 2,5) mg/m3 Range (0,0021 – 1,1) ppm Range (0,00012 – 0,060) mg w próbce |
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) | PN-Z-04045-16:2010 | |
| 37 | Workplace environment - air | Stężenie/ zawartość 1-metoksypropan-2-olu Range (4,44 – 950) mg/m3 Range (0,020 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04354:2005 | |
| 38 | Workplace environment - air | Concentration/ content of benzene Range (0,064 – 1,5) mg/m3 Range (0,020 – 0,46) ppm Range (0,00128 – 0,030) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-10:2005 | |
| 39 | Workplace environment - air | Concentration/ content of styrene Range (1,11 – 200) mg/m3 Range (0,005 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z-04152/02 | |
| 40 | Workplace environment - air | Concentration/ content of methanol Range (2,78 – 1000) mg/m3 Range (0,0125 – 5,0) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04476:2016-10 | |
| 41 | Workplace environment - air | Stężenie/ zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych - frakcja wdychalna Range (0,4 – 32) mg/m3 Range (0,2– 3,2) mg w próbce |
Fourier transform infrared spectrometry (FT-IR) | PN-Z-04108-5:2006 | |
| 42 | Workplace environment - air | Concentration/ content of ethylbenzene Range (1,11 – 800) mg/m3 Range (0,005 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-79/Z-04081/01 | |
| 43 | Workplace environment - air | Concentration/ content of propan-2-ol Range (36 – 2400) mg/m3 Range (0,162 – 16,2) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103), str. 157-170 | |
| 44 | Workplace environment - air | Concentration / content of acetone Range (1,11 – 3600) mg/m3 Range (0,005 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 45 | Workplace environment - air | Concentration/ content of ethanol Range (2,22 – 4222) mg/m3 Range (0,010 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | Procedura Badawcza PB-55 wydanie 1 z dnia 10.09.2020 r. | |
| 46 | Workplace environment - air | Concentration/ content of butan-1-ol Range (1,11 – 300) mg/m3 Range (0,005 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 47 | Workplace environment - air | Concentration/ content of ethyl acetate Range (1,11 – 3000) mg/m3 Range (0,304 – 821) ppm Range (0,005 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 48 | Workplace environment - air | Stężenie/ zawartość octanu n-butylu Range (1,11 – 1500) mg/m3 Range (0,005 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 49 | Workplace environment - air | Concentration/ content of xylene (mixture of isomers) Range (1,11 – 400) mg/m3 Range (0,005 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 50 | Workplace environment - air | Concentration/ content of toluene Range (1,11 – 400) mg/m3 Range (0,005 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 51 | Workplace environment - air | Concentration/ content of tetrachloroethene Range (1,11 – 340) mg/m3 Range (0,161 – 49) ppm Range (0,005 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-83/Z-04118/02 | |
| 52 | Workplace environment - air | Concentration/ content of hexane Range (1,11 – 144) mg/m3 Range (0,005 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04136-3:2003 | |
| 53 | Workplace environment - air | Stężenie/ zawartość butan-2-onu (metyloetyloketonu) Range (1,11 – 1800) mg/m3 Range (0,005 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-79/Z-04107/02 | |
| 54 | Workplace environment - air | Concentration/ content of acetic acid Range (0,8 – 100) mg/m3 Range (0,32 – 40) ppm Range (0,02 – 1,25) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04323:2004 | |
| 55 | Workplace environment - air | Concentration/ content of phenol Range (0,21 – 32) mg/m3 Range (0,005 – 0,500) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, str. 91-95 | |
| 56 | Workplace environment - air | Stężenie/ zawartość pentanu Range (4,44 – 6000) mg/m3 Range (0,020 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-84/Z 04135/02 | |
| 57 | Workplace environment - air | Concentration/ content of heptane Range (4,44 – 4000) mg/m3 Range (0,020 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-84/Z 04138/02 | |
| 58 | Workplace environment - air | Stężenie/ zawartość oktanu Range (4,44 – 3600) mg/m3 Range (0,02 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z 04166/02 | |
| 59 | Workplace environment - air | Stężenie/ zawartość benzyny C do lakierów Range (4,44 – 1800) mg/m3 Range (0,02 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z-04134/03 | |
| 60 | Workplace environment - air | Concentration/ content of extraction naphtha Range (4,44 – 3000) mg/m3 Range (0,02 – 19) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z 04134/02 | |
| 61 | Workplace environment - air | Stężenie/ zawartość glinu metalicznego, glin proszek (niestabilizowany) – frakcja wdychalna Range (0,10 – 10,0) mg/m3 respirable fraction Range (0,11 – 10,00) mg/m3 Range (0,075 – 7,5) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04263-1:2012 | |
| 62 | Workplace environment - air | Stężenie/ zawartość tritlenku glinu w przeliczeniu na Al – frakcja wdychalna Range (0,10 – 10,0) mg/m3 – respirable fraction Range (0,11 – 11,0) mg/m3 Range (0,075 – 7,5) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04263-1:2012 | |
| 63 | Workplace environment - air | Concentration/ content of metallic nickel Range (0,010 – 1,0) mg/m3 Range (0,0075 – 0,75) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04502:2019-10 | |
| 64 | Workplace environment - air | Stężenie/ zawartość związków niklu w przeliczeniu na Ni inhalable fraction Range (0,010 – 1,0) mg/m3 respirable fraction Range (0,0095 – 0,95) mg/m3 Range (0,0075 – 0,75) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04502:2019-10 | |
| 65 | Workplace environment - air | Stężenie / zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) - w przeliczeniu na Cr Range (0,017 – 3,5) mg/m3 Range (0,013– 2,5) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04434:2011 | |
| 66 | Workplace environment - air | Stężenie/ zawartość chromu metalicznego, Związki chromu (II) w przeliczeniu na chrom (II), Związki chromu (III)w przeliczeniu na chrom (III) (z obliczeń) | Procedura Badawcza PB-57 wydanie 1 z dnia 16.04 2021 r. | ||
| 67 | Workplace environment - air | Stężenie/zawartość tlenku cynku w przeliczeniu na Zn -frakcja wdychalna Range (0.014 – 10,0) mg/m3 Range (0,01 – 7,5) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-87/Z-04100.03 | |
| 68 | Workplace environment - air | Stężenie/ zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn -frakcja wdychalna Range (0,005 – 1,0) mg/m3 -respirable fraction Range (0,0047 – 0,95) mg/m3 Range (0,0037– 0,75) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04472:2015-10+Ap1:2015-12 | |
| 69 | Workplace environment - air | Concentration/ content of copper and its inorganic compounds calculated as Cu Range (0,005 – 1,0) mg/m3 Range (0,0037 – 0,75) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04106-3:2002 | |
| 70 | Workplace environment - air | Concentration/ content of iron oxides calculated as Fe Iron (III) oxide Iron (II) oxide Triiron tetraoxide inhalable fraction Range (0,02 – 8,0) mg/m3 -respirable fraction Range (0,02 – 8,0) mg/m3 Range (0,015 – 6) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04469:2015-10 | |
| 71 | Workplace environment - air | Concentration/ content of lead and its inorganic compounds - calculated as Pb inhalable fraction Range (0,005 – 1,0) mg/m3 Range (0,0035 – 0,7) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04487:2017-10 | |
| 72 | Workplace environment - air | Concentration/ content of manganese and its inorganic compounds calculated as Mn inhalable fraction Range (0,00347 – 0,69) mg/m3 Range (0,0025 – 0,50) mg w próbce respirable fraction Range (0,00316 – 0,63) mg/m3 Range (0,0025 – 0,50) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 73 | Workplace environment - air | Concentration/ content of iron oxides calculated as Fe Iron (III) oxide Iron (II) oxide Triiron tetraoxide inhalable fraction Range (0,069 – 20,0) mg/m3 Range (0,050 – 10,0) mg w próbce respirable fraction Range (0,063 – 10,0) mg/m3 Range (0,050 – 10,0) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 74 | Workplace environment - air | Stężenie/ zawartość srebra Range (0,00347 – 0,139) mg/m3 Range (0,0025 – 0,100) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 75 | Workplace environment - air | Stężenie/ zawartość glinu metalicznego, glin proszek (niestabilizowany) – frakcja wdychalna Range (0,069 – 6,9) mg/m3 Range (0,050 – 5,0) mg w próbce respirable fraction Range (0,063 – 6,3) mg/m3 Range (0,050 – 5,0) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 76 | Workplace environment - air | Stężenie/ zawartość tritlenku glinu w przeliczeniu na Al – frakcja wdychalna Range (0,069 – 6,9) mg/m3 Range (0,050 – 5,0) mg w próbce – respirable fraction Range (0,063 – 6,3) mg/m3 Range (0,050 – 5,0) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 77 | Workplace environment - air | Concentration/ content of calcium oxide inhalable fraction Range (0,053 – 12,0) mg/m3 Range (0,0378 – 3,78) mg w próbce respirable fraction Range (0,048 – 8,0) mg/m3 Range (0,0378 – 3,78) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 78 | Workplace environment - air | Concentration/ content of calcium hydroxide inhalable fraction Range (0,069 – 12,0) mg/m3 Range (0,050 – 5,0) mg w próbce respirable fraction Range (0,063 – 8,0) mg/m3 Range (0,050 – 5,0) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 79 | Workplace environment - air | Concentration/ content of cadmium and its inorganic compounds calculated as Cd inhalable fraction Range (0,00035 – 0,0139) mg/m3 Range (0,00025 – 0,0100) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 80 | Workplace environment - air | Concentration/ content of cobalt and its inorganic compounds calculated as Co Range (0,00139 – 0,069) mg/m3 Range (0,00100 – 0,050) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 81 | Workplace environment - air | Stężenie / zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) calculated as Cr Range (0,0347 – 1,39) mg/m3 Range (0,0250 – 1,00) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 82 | Workplace environment - air | Concentration/ content of copper and its inorganic compounds calculated as Cu Range (0,0139 – 0,69) mg/m3 Range (0,0100 – 0,50) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 83 | Workplace environment - air | Stężenie/ zawartość wodorotlenku potasu Range (0,0139 – 2,00) mg/m3 Range (0,0100 – 1,00) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 84 | Workplace environment - air | Stężenie/ zawartość wodorotlenku sodu Range (0,0139 – 2,00) mg/m3 Range (0,0100 – 1,00) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 85 | Workplace environment - air | Concentration/ content of metallic nickel Range (0,00069 – 0,69) mg/m3 Range (0,00050 – 0,50) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 86 | Workplace environment - air | Stężenie/ zawartość związków niklu w przeliczeniu na Ni inhalable fraction Range (0,00069 – 0,69) mg/m3 Range (0,00050 – 0,50) mg w próbce respirable fraction Range (0,00063 – 0,63) mg/m3 Range (0,00050 – 0,50) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 87 | Workplace environment - air | Concentration/ content of lead and its inorganic compounds - calculated as Pb inhalable fraction Range (0,00347 – 0,139) mg/m3 Range (0,00250 – 0,100) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 88 | Workplace environment - air | Stężenie/ zawartość cyny i jej związków nieorganicznych, z wyjątkiem stannanu – w przeliczeniu na Sn inhalable fraction Range (0,139 – 6,9) mg/m3 Range (0,100 – 5,0) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 89 | Workplace environment - air | Stężenie/ zawartość tytanu i jego związków – w przeliczeniu na Ti Range (0,347 – 60) mg/m3 Range (0,250 – 15,0) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 90 | Workplace environment - air | Stężenie/zawartość tlenku cynku w przeliczeniu na Zn -frakcja wdychalna Range (0,139 – 20,0) mg/m3 Range (0,100 – 10,0) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r. | |
| 91 | Workplace environment - air | Nitrogen oxide concentration / content Range (0,125 – 14,6) mg/m3 Range (0,100 – 11,7) ppm Range (0,003 – 0,35) mg w próbce |
Ion chromatography with conductometric detection (IC-CD) | OSHA Method 190 | |
| 92 | Workplace environment - air | Nitrogen dioxide concentration / content Range (0,063 – 4,20) mg/m3 Range (0,033 – 2,2) ppm Range (0,0015 – 0,10) mg w próbce |
Ion chromatography with conductometric detection (IC-CD) | OSHA Method 182 | |
| 93 | Workplace environment - air | Concentration / content of sulphur dioxide Range (0,046 – 6,9) mg/m3 Range (0,017 – 2,6) ppm Range (0,033 – 5,0) mg w próbce |
Ion chromatography with conductometric detection (IC-CD) | OSHA Method 1011 | |
| 94 | Workplace environment - air | Hydrogen sulphide concentration / content Range (0,63 – 14,6) mg/m3 Range (0,015 – 0,35) mg w próbce |
Ion chromatography with conductometric detection (IC-CD) | OSHA Method 1008 | |
| 95 | Workplace environment - air | Concentration / content of sulphuric (VI) acid – thoracic fraction Range (0,0043 – 0,17) mg/m3 Range (0,0025 – 0,10) mg w próbce |
Ion chromatography with conductometric detection (IC-CD) | Podstawy i Metody Oceny Środowiska Pracy 2017 nr 2(92), str. 5-19 | |
| 96 | Workplace environment - air | Hydrogen chloride concentration / content Range (0,14 – 20,8) mg/m3 Range (0,10 – 15) mg w próbce |
Ion chromatography with conductometric detection (IC-CD) | NIOSH 7907 Method, Issue 1, 20 May 2014 | |
| 97 | Workplace environment - air | Concentration / content of nitric (V) acid Range (0,035 – 7,1) mg/m3 Range (0,025 – 5,1) mg w próbce |
Ion chromatography with conductometric detection (IC-CD) | NIOSH 7907 Method, Issue 1, 20 May 2014 | |
| 98 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Velocity Range (1,0 – 35) m/s Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Stagnation pressure method; Anemometric method | PN-Z-04030-7:1994 | |
| 99 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-Z-04030-7:1994 | ||
| 100 | Waste gases | Dust concentration Range (0,001 – 10) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Gravimetric method | PN-Z-04030-7:1994 | |
| 101 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-Z-04030-7:1994 | ||
| 102 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 13284-1:2018-02 | ||
| 103 | Waste gases | Dust concentration Range (1,0 – 50) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 104 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 13284-1:2018-02 | ||
| 105 | Waste gases | Stężenie CO, SO2, CO2, NOX, O2 O2 (1,0 – 21) % CO2 (0,1 – 20) % CO (2,0 – 1400) mg/m3 SO2 (3,0 – 3000) mg/m3 NO (9 – 435) mg/m3 NOx (14 – 700) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Metoda elektrochemiczna; Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) | PN-ISO 10396:2001 | |
| 106 | Waste gases | Emisja CO, SO2, CO2, NO, NOX (NO i NO2 w przeliczeniu na NO2) (z obliczeń) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-ISO 10396:2001 | ||
| 107 | Waste gases | CO concentration Range (2,0 – 1400) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) | PN-EN 15058:2017-04 | |
| 108 | Waste gases | CO emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 15058:2017-04 | ||
| 109 | Waste gases | NO, NOx concentration NO (1,3 – 435) mg/m3 NOx (2,0 – 700) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Chemiluminescence method (CLD) | PN-EN 14792:2017-04 | |
| 110 | Waste gases | Emission of NO, NOx (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 14792:2017-04 | ||
| 111 | Waste gases | Sampling for determination of SO2 concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 14791:2017-04 | ||
| 112 | Waste gases | SO2 concentration Range (5,0 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Thoron method | PN-EN 14791:2017-04 | |
| 113 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 14791:2017-04 | ||
| 114 | Waste gases | Water vapour concentration (H2O) Range (4,0 – 40) % Range (29 – 250) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Condensation-absorption method | PN-EN 14790:2017-04 | |
| 115 | Waste gases | Oxygen concentration Range (3,0 – 21,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Paramagnetic method | PN-EN 14789:2017-04 | PN-ISO 10396:2001 | |
| 116 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (1,8 – 1000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Metoda ciągłej detekcji płomieniowo-jonizacyjną (FID) | PN-EN 12619:2013-05 | |
| 117 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 12619:2013-05 | ||
| 118 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 13649:2005 | ||
| 119 | Waste gases | Stężenie/ zawartość indywidualnych gazowych związków organicznych acetone (0,5 – 1900) mg/m3 Range (0,005 – 19) mg w próbce butan-1-ol (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce etanolu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce metanolu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce octanu etylu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce octanu butylu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce toluenu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce ksylenu (mieszanina izomerów) (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce benzenu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce etylobenzenu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce butan-2-on (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Gas chromatography with flame ionization detection (GC - FID) | PN-EN 13649:2005 | |
| 120 | Waste gases | Stężenie/ zawartość indywidualnych gazowych związków organicznych acetic acid Range (0,5 – 125) mg/m3 Range (0,005 – 1,25) mg w próbce pentane (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce heksanu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce heptanu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce oktanu (0,5 – 1900) mg/m3 (0,005 – 19) mg w próbce Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Gas chromatography with flame ionization detection (GC - FID) | PN-EN 13649:2005 | |
| 121 | Waste gases | Sum of aromatic hydrocarbons: benzene, toluene, ethylbenzene, xylenes (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 13649:2005 | ||
| 122 | Waste gases | Emission of individual gaseous organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 13649:2005 | ||
| 123 | Waste gases | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 14385:2025-05 | ||
| 124 | Waste gases | Stężenie/ zawartość metali Antimony (0,023 – 1,0) mg/m3 Range (0,025 – 2,0) mg w próbce arsenic (0,023 – 1,0) mg/m3 (0,025 – 2,0) mg w próbce chrom (0,0023 – 1,0) mg/m3 (0,0025 – 2,5) mg w próbce kadm (0,00093 – 1,00) mg/m3 (0,001 – 2,0) mg w próbce kobalt (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg w próbce mangan (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg w próbce miedź (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg w próbce nikiel (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg w próbce ołów (0,0046 – 1,0) mg/m3 (0,005 – 2,0) mg w próbce tal (0,023 – 1,0) mg/m3 (0,025 – 2,0) mg w próbce wanad (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg w próbce Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN 14385:2025-05 | |
| 125 | Waste gases | Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 14385:2025-05 | ||
| 126 | Waste gases | Sampling for determination of styrene concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-93/Z-04152/06 | ||
| 127 | Waste gases | Concentration/ content of styrene Range (0,5 – 1900) mg/m3 Range (0,005 – 19) mg w próbce Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC FID) | PN-93/Z-04152/06 | |
| 128 | Waste gases | Emission of styrene (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-93/Z-04152/06 | ||
| 129 | Waste gases | Sampling for determination of tetrachloroethene concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 13649:2005 | ||
| 130 | Waste gases | Concentration/ content of tetrachloroethene Range (0,5 – 1900) mg/m3 Range (0,005 –19) mg w próbce Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 131 | Waste gases | Emission of tetrachloroethene (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 13649:2005 | ||
| 132 | Waste gases | Pobieranie próbek do oznaczania stężenia węglowodorów alifatycznych suma C5 – C12 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 13649:2005 | ||
| 133 | Waste gases | Stężenie/ zawartość węglowodorów alifatycznych suma C5 – C12 Range (0,5 – 1900) mg/m3 Range (0,005 – 19) mg w próbce Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 134 | Waste gases | Emisja węglowodorów alifatycznych suma C5 – C12 (z obliczeń) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 13649:2005 | ||
| 135 | Waste gases | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 13211+AC:2006 | ||
| 136 | Waste gases | Total mercury emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 13211+AC:2006 | ||
| 137 | Waste gases | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 1911:2011 | ||
| 138 | Waste gases | Hydrogen chloride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 1911:2011 | ||
| 139 | Waste gases | Sampling for determination of the concentration of gaseous fluorides Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
ISO 15713:2006 | ||
| 140 | Waste gases | Emission of gaseous fluorides (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
ISO 15713:2006 | ||
| 141 | Automated Measuring Systems (AMS) | Kalibracja AMS (QAL2) w zakresie: pyłu, O2, CO2, CO, NOx, NO, SO2 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 14181:2015 | ||
| 142 | Automated Measuring Systems (AMS) | Roczne badanie kontrolne (AST) w zakresie: pyłu, O2, CO2, CO, NOx, NO, SO2 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
PN-EN 14181:2015 | ||
| 143 | Automated Measuring Systems (AMS) | Dust concentration Range (0,001 – 10 ) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Gravimetric method | PN-Z-04030-7:1994 | |
| 144 | Automated Measuring Systems (AMS) | Dust concentration Range (1 – 50) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 145 | Automated Measuring Systems (AMS) | Oxygen concentration Range (3,0 – 21,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Paramagnetic method | PN-EN 14789:2017-04 | |
| 146 | Automated Measuring Systems (AMS) | CO2 concentration Range (0,1 – 20,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) | PN-ISO 10396:2001 | |
| 147 | Automated Measuring Systems (AMS) | CO concentration Range (2,0 – 1400) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) | PN-EN 15058:2017-04 | |
| 148 | Automated Measuring Systems (AMS) | NO, NOx concentration NO (1,3 – 435) mg/m3 NOx (2,0 – 700) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Chemiluminescence method (CLD) | PN-EN 14792:2017-04 | |
| 149 | Automated Measuring Systems (AMS) | SO2 concentration Range (5 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Thoron method | PN-EN 14791:2017-04 | |
| 150 | Automated Measuring Systems (AMS) | Water vapour concentration (H2O) Range (4,0 – 40) % Range (29 – 250) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Metoda kondensacyjno - absorpcyjna | PN-EN 14790:2017-04 | |
| 151 | Waste gases | Dust sampling for determination of the fraction composition | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | ||
| 152 | Waste gases | Emission of the dust fraction (calculated) | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | ||
| 153 | Waste gases | Sampling for determination of formaldehyde concentration | Aspiration method using absorbing solutions | Procedura Badawcza PB-14 wydanie 10 z dnia 18.09.2019 r. | |
| 154 | Waste gases | Concentration/ content of formaldehyde Range (0,2 – 100) mg/m3 Range (0,0005 – 0,02) mg w próbce |
Spectrophotometric method | Procedura Badawcza PB-14 wydanie 10 z dnia 18.09.2019 r. | |
| 155 | Waste gases | Formaldehyde emission (calculated) | Procedura Badawcza PB-14 wydanie 10 z dnia 18.09.2019 r. | ||
| 156 | Waste gases | Sampling for determination of phenol concentration | Aspiration method using absorbing solutions | Procedura Badawcza PB-13 wydanie 10 z dnia 18.09.2019 r. | |
| 157 | Waste gases | Concentration/ content of phenol Range (0,1 – 100) mg/m3 Range (0,005 – 19) mg w próbce |
Spectrophotometric method | Procedura Badawcza PB-13 wydanie 10 z dnia 18.09.2019 r. | |
| 158 | Waste gases | Phenol emission (calculated) | Procedura Badawcza PB-13 wydanie 10 z dnia 18.09.2019 r. | ||
| 159 | Waste gases | Sampling for determination of ammonia concentration | Aspiration method using absorbing solutions | PN-EN ISO 21877:2020-03 | |
| 160 | Waste gases | Ammonia concentration/ content Range (0,17 – 100) mg/m3 Range (0,005 – 2) mg w próbce |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
| 161 | Waste gases | Ammonia emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 162 | Waste gases | Sampling for determination of metal concentrations: Fe, Zn | PN-EN 14385:2025-05 | ||
| 163 | Waste gases | Emission of metals: Fe, Zn (calculated) | PN-EN 14385:2025-05 | ||
| 164 | Waste gases | Stężenie/ zawartość metali zinc (0,0046 – 5,0) mg/m3 Range (0,005 – 10,0) mg w próbce iron (0,023 – 5,00) mg/m3 (0,025 – 10,0) mg w próbce |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB 58 wydanie 1 z dnia 16.04.2021 r. | |
| 165 | Waste gases | Sampling for determination of formaldehyde concentration | Procedura Badawcza PB 52 wydanie 3 z dnia 28.08.2019 r. | ||
| 166 | Waste gases | Concentration/ content of formaldehyde Range (0,08 – 60) mg/m3 Range (0,0008 – 0,06) mg w próbce |
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) | Procedura Badawcza PB 52 wydanie 3 z dnia 28.08.2019 r. | |
| 167 | Waste gases | Formaldehyde emission (calculated) | Procedura Badawcza PB 52 wydanie 3 z dnia 28.08.2019 r. | ||
| 168 | Waste gases | Pobieranie próbek do oznaczania stężenia akrylaldehydu | Procedura Badawcza PB 54 wydanie 1 z dnia 15.05.2020 r. | ||
| 169 | Waste gases | Stężenie/ zawartość akrylaldehydu Range (0,012 – 60) mg/m3 Range (0,00012 – 0,060) mg w próbce |
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) | Procedura Badawcza PB 54 wydanie 1 z dnia 15.05.2020 r. | |
| 170 | Waste gases | Emisja akrylaldehydu (z obliczeń) | Procedura Badawcza PB 54 wydanie 1 z dnia 15.05.2020 r. | ||
| 171 | Dust samples | Zawartość frakcji pyłu (składu ziarnowego), w tym PM2,5 i PM10 Range (0,6 – 1200) μm Range (0 – 100) % |
Metoda elektrycznej strefy wykrywania | ISO 13319-1:2021 | |
| 172 | Water, wastewater | Indeks oleju mineralnego (węglowodory ropopochodne C10-C40) Range (0,80 – 44,0) mg/l |
Gas chromatography with flame ionization detection (GC - FID) | PN-EN ISO 9377-2:2003 | |
| 173 | Water, wastewater | pH range (2,0 – 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 174 | Water, wastewater | Electrical conductivity Range (147 – 1600) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 175 | Water, wastewater | Chemical oxygen demand COD-Cr Range (10,0 – 2 000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 176 | Water, wastewater | Biochemical oxygen demand BOD5 Range (0,50 – 6,0) mg/l O2 |
Titrimetric method; Electrochemical method | PN-EN 1899-2:2002 | |
| 177 | Water, wastewater | Biochemical oxygen demand BOD5 Range (3,0 – 2000) mg/l O2 |
Titrimetric method; Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 178 | Water, wastewater | Total phosphorus concentration Range (0,050 – 40,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt.8 +Ap1:2010 + Ap2:2010 | |
| 179 | Water, wastewater | Phosphate concentration Range (0,050 – 40,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt.4 +Ap1:2010 + Ap2:2010 | |
| 180 | Water, wastewater | Total suspended solids (TSS) Range (5,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007 + Ap1:2007 | |
| 181 | Water, wastewater | Metal concentrations zinc (0,005 – 10) mg/l cadmium (0,010 – 10) mg/l copper (0,025 – 25) mg/l nickel (0,025 – 25) mg/l lead (0,05 – 50) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 metoda A IR-106 wydanie 1 z dnia 05.11.2018 r. pkt.3.1.4 | |
| 182 | Water, wastewater | Iron concentration Range (0,05 – 50) mg/l |
Flame atomic absorption spectrometry (FAAS) | Procedura Badawcza PB-37 wydanie 5 z dnia 24.06.2019 r. | |
| 183 | Water, wastewater | Total chromium concentration Range (0,05 – 8,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-EN 1233:2000 pkt.3 | |
| 184 | Water, wastewater | Sulfate concentration Range (10 – 1000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 185 | Water, wastewater | Ammonium nitrogen concentration Range (0,10 – 160) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 186 | Water, wastewater | Nitrite nitrogen concentration Range (0,030 – 10) mg/l Nitrite concentration Range (0,098 – 33) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 187 | Water, wastewater | Nitrate nitrogen concentration Range (0,40 – 100) mg/l Nitrate concentration Range (1,77 – 443) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 188 | Water, wastewater | Dissolved solids concentration Range (10,0 – 2500) mg/l |
Gravimetric method | Procedura Badawcza PB-23 wydanie 7 z dnia 24.06.2019 r. | |
| 189 | Water, wastewater | Metal concentrations chromium (0,0125 – 5,0) mg/l zinc (0,25 – 10) mg/l aluminium (0,050 – 10) mg/l cadmium (0,0050 – 1,0) mg/l manganese (0,025 – 5,0) mg/l copper (0,0125 – 5,0) mg/l nickel (0,0125 – 5,0) mg/l lead (0,025 – 5,0) mg/l iron (0,050 – 10) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 190 | Wastewater | Sampling for chemical testing and physical properties Temperature Range (0,0 – 50,0) oC |
Manual method | PN-ISO 5667-10:2021-11 Procedura Badawcza PB-20 wydanie 8 z dnia 01.03.2022 r. | |
| 191 | Wastewater | Kjeldahl nitrogen concentration Range (3,0 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 192 | Wastewater | Total nitrogen concentration (calculated) | Procedura Badawcza PB–22 wydanie 6 z dnia 24.06.2019 r. | ||
| 193 | Wastewater | Chloride concentration Range (5,0 – 1000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 194 | Water | Chloride concentration Range (5,0 – 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 195 | Soil | pH - in KCl Range (2,0 – 10,0) |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 196 | Soil | Dry matter content Range (50,0 – 99,0) % |
Gravimetric method | PN-ISO 11465:2026-03 | |
| 197 | Soil | Water content Range (1,0 – 50,0) % |
Gravimetric method | PN-ISO 11465:2026-03 | |
| 198 | Soil, ground | Sampling for physical and chemical testing | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 | ||
| 199 | Soil, ground | Metal content arsenic (8,3 – 500) mg/kg barium (16,7 – 5000) mg/kg chromium (3,3 – 2000) mg/kg tin (8,3 – 500) mg/kg zinc (3,3 – 5000) mg/kg cadmium (0,83 – 50) mg/kg cobalt (1,7 – 500) mg/kg copper (3,3 – 2000) mg/kg molybdenum (3,3 – 500) mg/kg nickel (3,3 – 1000) mg/kg lead (8,3 – 1000) mg/kg |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-ISO 11466:2002 | PN-EN ISO 11885:2009 | |
| 200 | Soil, ground | Mercury concentration and content Range (0,20 – 100) mg/kg |
Cold vapour atomic absorption spectrometry (CVAAS) | PN-ISO 16772:2009 | |
| 201 | Soil, ground | Suma węglowodorów C6 - C12 (składników frakcji benzyn) Range (1,0 – 1000) mg/kg |
Headspace gas chromatography with flame ionization detection (HS-GC-FID) | Procedura Badawcza PB-59 wydanie 1 z dnia 01.03.2022 r. | |
| 202 | Soil, ground | Suma węglowodorów C12 – C35 (składników frakcji oleju) Range (30 – 5000) mg/kg |
Gas chromatography with flame ionization detection (GC-FID) | Procedura Badawcza PB-60 wydanie 1 z dnia 01.03.2022 r. | |
| 203 | Soil, ground | Aromatic hydrocarbon content benzene (0,10 – 250) mg/kg ethylbenzene (0,10 – 250) mg/kg toluene (0,10 – 250) mg/kg ksyleny (m,p,o) (0,10 – 250) mg/kg styrene (0,10 – 250) mg/kg |
Headspace gas chromatography with flame ionization detection (HS-GC-FID) | PN-EN ISO 22155:2016-07 | |
| 204 | Soil, ground | Content of polycyclic aromatic hydrocarbons PAH naphthalene (0,020 – 100) mg/kg anthracene (0,020 – 100) mg/kg chrysene (0,020 – 100) mg/kg benzo(a)anthracene Range (0,020 – 100) mg/kg dibenzo(ah)anthracene (0,020 – 100) mg/kg benzo(a)pyrene (0,020 – 100) mg/kg benzo(b)fluoranthene (0,020 – 100) mg/kg benzo(k)fluoranthene (0,020 – 100) mg/kg benzo(ghi)perylene (0,020 – 100) mg/kg indeno (1,2,3,c,d)piren (0,020 – 100) mg/kg |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PN-ISO 13877:2004 | |
| 205 | WasteO) code: 10 01 01 20 01 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Moisture content Range (0,20 – 42,0) % |
Gravimetric method | PN-93/Z-15008/02 | |
| 206 | WasteO) code: 10 01 01 20 01 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Combustible matter content Range (1,00 – 80,00) % |
Gravimetric method | PN-93/Z-15008/03 | |
| 207 | WasteO) code: 10 01 01 20 01 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Content of non-combustible parts (calculated) | PN-93/Z-15008/03 | ||
| 208 | WasteO) code: 10 01 01 20 01 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Metal content Al (10000 – 1000000) mg/kg Cd (4 – 10000) mg/kg Co (40 – 10000) mg/kg Cr (50 – 100000) mg/kg Cu (140 – 1000000) mg/kg Fe (5000 – 1000000) mg/kg Mn (200 – 100000) mg/kg Ni (75 – 100000) mg/kg Pb (40 – 10000) mg/kg Ti (5000 – 100000) mg/kg Zn (150 – 1000000) mg/kg |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Procedura Badawcza PB–53 wydanie 2 z dnia 07.07.2020 r. | |
| 209 | Heating boilers for solid fuels with manual and automatic fuel feeding | Moc cieplna Range (0 – 500) kW Temperatura wody wylotowej Temperatura wody na powrocie Temperatura otoczenia Range (10 – 100 ) °C Strumień objętości wody Range (0,1 – 20,0 m3/h) Strumień masy paliwa Range (0,5 – 100 kg/h) Temperatura spalin wylotowych Range ( 50 – 300 ) °C Ciśnienie spalin Range ( -150 – 50 ) hPa |
Metoda bezpośrednia; Metoda rezystancyjna; Metoda ultradźwiękowa; Metoda wagowa; Metoda rezystancyjna; Metoda piezorezystancyjna | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5:2021-09 p. 5.7 | PN-EN 303-5:2021-09 p. 5.8 | PN-EN 303-5 +A1:2023-05 p. 5.2 | PN-EN 303-5 +A1:2023-05 p. 5.7 | PN-EN 303-5 +A1:2023-05 p. 5.8 | EN 303-5:2021+A1:2022 p. 5.2 | EN 303-5:2021+A1:2022 p. 5.7 | EN 303-5:2021+A1:2022 p. 5.8 | |
| 210 | Heating boilers for solid fuels with manual and automatic fuel feeding | Stężenie tlenu, ditlenku węgla, tlenku węgla, tlenków azotu, ditlenku siarki, lotnych związków organicznych O2 (1 – 21) % CO2 (0,1 – 20) % CO (3 – 1400) mg/m3 SO2 (19 – 3000) mg/m3 NO (9,0 – 435) mg/m3 NOX (14,0 – 700) mg/m3 OGC (1,8 – 1000) mg/m3 Stężenie pyłów w gazach spalinowych Range (1,0 – 100) mg/m3 |
Metoda elektrochemiczna - O2 (3,0 – 21,0) %; Metoda paramagnetyczna; Metoda NDIR; Metoda chemiluminescencji; Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID); Metoda grawimetryczna | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5:2021-09 p. 5.7 | PN-EN 303-5:2021-09 p. 5.8 | PN-EN 303-5 +A1:2023-05 p. 5.2 | PN-EN 303-5 +A1:2023-05 p. 5.7 | PN-EN 303-5 +A1:2023-05 p. 5.8 | EN 303-5:2021+A1:2022 p. 5.2 | EN 303-5:2021+A1:2022 p. 5.7 | EN 303-5:2021+A1:2022 p. 5.8 | |
| 211 | Heating boilers for solid fuels with manual and automatic fuel feeding | Emisja tlenu, ditlenku węgla, tlenku węgla, tlenków azotu, ditlenku siarki, lotnych związków organicznych O2 (1– 21) % CO2 (0,1 – 20) % CO (3 – 1400) mg/m3 SO2 (19 – 3000) mg/m3 NO (9,0 – 435) mg/m3 NOX (14,0 – 700) mg/m3 OGC (1,8 – 1000) mg/m3 Stężenie pyłów w gazach spalinowych Range (1,0 – 100) mg/m3 |
Metoda elektrochemiczna - O2 (3,0 – 21,0) %; Metoda paramagnetyczna; Metoda NDIR; Metoda chemiluminescencji; Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID); Metoda grawimetryczna | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5:2021-09 p. 5.8 | PN-EN 303-5:2021-09 p. 5.9.4 | PN-EN 303-5 +A1:2023-05 p. 5.2 | PN-EN 303-5 +A1:2023-05 p. 5.8 | PN-EN 303-5 +A1:2023-05 p. 5.9.4 | EN 303-5:2021+A1:2022 p. 5.2 | EN 303-5:2021+A1:2022 p. 5.8 | EN 303-5:2021+A1:2022 p. 5.9.4 | |
| 212 | Heating boilers for solid fuels with manual and automatic fuel feeding | Nominalna moc cieplna Range (0 – 500) kW |
Direct method | PN-EN 303-5:2021-09 p. 5.7.2 | PN-EN 303-5 +A1:2023-05 p. 5.7.2 | EN 303-5:2021+A1:2022 p. 5.7.2 | |
| 213 | Heating boilers for solid fuels with manual and automatic fuel feeding | Minimalna moc cieplna Range (0 – 500) kW |
Direct method | PN-EN 303-5:2021-09 p. 5.7.3 | PN-EN 303-5 +A1:2023-05 p. 5.7.3 | EN 303-5:2021+A1:2022 p. 5.7.3 | |
| 214 | Heating boilers for solid fuels with manual and automatic fuel feeding | Sprawność cieplna | Metoda bezpośrednia (z obliczeń) | PN-EN 303-5:2021-09 p. 5.7.6 | PN-EN 303-5:2021-09 p. 5.9.3.2 | PN-EN 303-5 +A1:2023-05 p. 5.7.6 | PN-EN 303-5 +A1:2023-05 p. 5.9.3.2 | EN 303-5:2021+A1:2022 p. 5.7.6 | EN 303-5:2021+A1:2022 p. 5.9.3.2 | |
| 215 | Heating boilers for solid fuels with manual and automatic fuel feeding | Sprawność cieplna | Metoda pośrednia (z obliczeń) | PN-EN 303-5:2021-09 p. 5.9.3.3 | PN-EN 303-5 +A1:2023-05 p. 5.9.3.3 | EN 303-5:2021+A1:2022 p. 5.9.3.3 | |
| 216 | Heating boilers for solid fuels with manual and automatic fuel feeding | Zużycie pomocniczej energii elektrycznej Range (1 – 4000) W |
Metoda: przetwornik mocy | PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5 +A1:2023-05 p. 5.7.7 | EN 303-5:2021+A1:2022 p. 5.7.7 | |
| 217 | Heating boilers for solid fuels with manual and automatic fuel feeding | Useful efficiency nGCV (calculated) | PN-EN 303-5:2021-09 p. 5.9.3.4 | PN-EN 303-5 +A1:2023-05 p. 5.9.3.4 | EN 303-5:2021+A1:2022 p. 5.9.3.4 | ||
| 218 | Heating boilers for solid fuels with manual and automatic fuel feeding | Seasonal space heating energy efficiency ns (calculated) | PN-EN 303-5:2021-09 p. 5.9.3.5 | PN-EN 303-5 +A1:2023-05 p. 5.9.3.5 | EN 303-5:2021+A1:2022 p. 5.9.3.5 | ||
| 219 | Heating boilers for solid fuels with manual and automatic fuel feeding | Energy efficiency index EEI (calculated) | PN-EN 303-5:2021-09 p. 5.9.3.6 | PN-EN 303-5 +A1:2023-05 p. 5.9.3.6 | EN 303-5:2021+A1:2022 p. 5.9.3.6 | ||
| 220 | Heating boilers for solid fuels with manual and automatic fuel feeding | Seasonal space heating emissions Es (calculated) | PN-EN 303-5:2021-09 p. 5.9.4.4 | PN-EN 303-5 +A1:2023-05 p. 5.9.4.4 | EN 303-5:2021+A1:2022 p. 5.9.4.4 | ||
| 221 | Heating boilers for solid fuels with manual and automatic fuel feeding | Surface temperature Range (15 – 150) °C |
Metoda rezystancyjna | PN-EN 303-5:2021-09 p. 5.11 | PN-EN 303-5 +A1:2023-05 p. 5.11 | EN 303-5:2021+A1:2022 p. 5.11 | |
| 222 | Heating boilers for solid fuels with manual and automatic fuel feeding | Temperatura uchwytów Range (0 – 150) °C |
Metoda rezystancyjna | PN-EN 303-5:2021-09 p. 5.11 | PN-EN 303-5 +A1:2023-05 p. 5.11 | EN 303-5:2021+A1:2022 p. 5.11 | |
| 223 | Heating boilers for solid fuels with manual and automatic fuel feeding | Działanie regulatora temperatury temperatura wody wylotowej Range (60 – 110) °C |
Metoda rezystancyjna | PN-EN 303-5:2021-09 p. 5.13 | PN-EN 303-5 +A1:2023-05 p. 5.13 | EN 303-5:2021+A1:2022 p. 5.13 | |
| 224 | Heating boilers for solid fuels with manual and automatic fuel feeding | Działanie ogranicznika temperatury bezpieczeństwa temperatura wody wylotowej Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) % |
Metoda rezystancyjna; Metoda NDIR | PN-EN 303-5:2021-09 p. 5.13 | PN-EN 303-5 +A1:2023-05 p. 5.13 | EN 303-5:2021+A1:2022 p. 5.13 | |
| 225 | Heating boilers for solid fuels with manual and automatic fuel feeding | Działanie systemów szybkowyłączalnych: zanik napięcia awaria odbioru ciepła temperatura wody wylotowej Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) % |
Metoda rezystancyjna; Metoda NDIR | PN-EN 303-5:2021-09 p. 5.14 | PN-EN 303-5 +A1:2023-05 p. 5.14 | EN 303-5:2021+A1:2022 p. 5.14 | |
| 226 | Heating boilers for solid fuels with manual and automatic fuel feeding | Badanie w warunkach przy zablokowaniu zasilania paliwem temperatura wody wylotowej Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) % |
Metoda rezystancyjna; Metoda NDIR | PN-EN 303-5:2021-09 p. 5.16.2 | PN-EN 303-5 +A1:2023-05 p. 5.16.2 | EN 303-5:2021+A1:2022 p. 5.16.2 | |
| 227 | Heating boilers for solid fuels with manual and automatic fuel feeding | Badanie bezpieczeństwa przy zaniku dopływu powietrza. Awaria wentylatora powietrza, awaria układu doprowadzania powietrza Carbon monoxide content CO (0,4 – 5,0) % |
NDIR method | PN-EN 303-5:2021-09 p. 5.16.3 | PN-EN 303-5 +A1:2023-05 p. 5.16.3 | EN 303-5:2021+A1:2022 p. 5.16.3 | |
| 228 | Heating boilers for solid fuels with manual and automatic fuel feeding | Badanie bezpieczeństwa w zakresie przewodzenia ciepła temperature Range (15 – 150) °C |
Metoda rezystancyjna | PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4 | EN 303-5:2021+A1:2022 p. 5.16.4 | |
Reference standards (179)
EN 303-5:2021+A1:2022 p. 5.11
EN 303-5:2021+A1:2022 p. 5.13
EN 303-5:2021+A1:2022 p. 5.14
EN 303-5:2021+A1:2022 p. 5.16.2
EN 303-5:2021+A1:2022 p. 5.16.3
EN 303-5:2021+A1:2022 p. 5.16.4
EN 303-5:2021+A1:2022 p. 5.2
EN 303-5:2021+A1:2022 p. 5.7
EN 303-5:2021+A1:2022 p. 5.7.2
EN 303-5:2021+A1:2022 p. 5.7.3
EN 303-5:2021+A1:2022 p. 5.7.6
EN 303-5:2021+A1:2022 p. 5.7.7
EN 303-5:2021+A1:2022 p. 5.8
EN 303-5:2021+A1:2022 p. 5.9.3.2
EN 303-5:2021+A1:2022 p. 5.9.3.3
EN 303-5:2021+A1:2022 p. 5.9.3.4
EN 303-5:2021+A1:2022 p. 5.9.3.5
EN 303-5:2021+A1:2022 p. 5.9.3.6
EN 303-5:2021+A1:2022 p. 5.9.4
EN 303-5:2021+A1:2022 p. 5.9.4.4
ISO 13319-1:2021
ISO 15713:2006
NIOSH 7907 Method, Issue 1, 20 May 2014
OSHA Method 1008
OSHA Method 1011
OSHA Method 182
OSHA Method 190
PN-71/Z-04041
PN-79/Z-04081/01
PN-79/Z-04107/02
PN-81/Z 04134/02
PN-81/Z-04134/03
PN-82/C-04576/08
PN-83/E-04040.03
PN-83/Z-04118/02
PN-84/Z 04135/02
PN-84/Z 04138/02
PN-86/Z 04166/02
PN-86/Z-04152/02
PN-87/Z-04100.03
PN-89/Z-04023/02
PN-93/Z-04152/06
PN-93/Z-15008/02
PN-93/Z-15008/03
PN-EN 1233:2000 pkt.3
PN-EN 12619:2013-05
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14181:2015
PN-EN 14253+A1:2011
PN-EN 14385:2025-05
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
PN-EN 1899-2:2002
PN-EN 1911:2011
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 303-5 +A1:2023-05 p. 5.11
PN-EN 303-5 +A1:2023-05 p. 5.13
PN-EN 303-5 +A1:2023-05 p. 5.14
PN-EN 303-5 +A1:2023-05 p. 5.16.2
PN-EN 303-5 +A1:2023-05 p. 5.16.3
PN-EN 303-5 +A1:2023-05 p. 5.16.4
PN-EN 303-5 +A1:2023-05 p. 5.2
PN-EN 303-5 +A1:2023-05 p. 5.7
PN-EN 303-5 +A1:2023-05 p. 5.7.2
PN-EN 303-5 +A1:2023-05 p. 5.7.3
PN-EN 303-5 +A1:2023-05 p. 5.7.6
PN-EN 303-5 +A1:2023-05 p. 5.7.7
PN-EN 303-5 +A1:2023-05 p. 5.8
PN-EN 303-5 +A1:2023-05 p. 5.9.3.2
PN-EN 303-5 +A1:2023-05 p. 5.9.3.3
PN-EN 303-5 +A1:2023-05 p. 5.9.3.4
PN-EN 303-5 +A1:2023-05 p. 5.9.3.5
PN-EN 303-5 +A1:2023-05 p. 5.9.3.6
PN-EN 303-5 +A1:2023-05 p. 5.9.4
PN-EN 303-5 +A1:2023-05 p. 5.9.4.4
PN-EN 303-5:2021-09 p. 5.11
PN-EN 303-5:2021-09 p. 5.13
PN-EN 303-5:2021-09 p. 5.14
PN-EN 303-5:2021-09 p. 5.16.2
PN-EN 303-5:2021-09 p. 5.16.3
PN-EN 303-5:2021-09 p. 5.16.4
PN-EN 303-5:2021-09 p. 5.2
PN-EN 303-5:2021-09 p. 5.7
PN-EN 303-5:2021-09 p. 5.7.2
PN-EN 303-5:2021-09 p. 5.7.3
PN-EN 303-5:2021-09 p. 5.7.6
PN-EN 303-5:2021-09 p. 5.7.7
PN-EN 303-5:2021-09 p. 5.8
PN-EN 303-5:2021-09 p. 5.9.3.2
PN-EN 303-5:2021-09 p. 5.9.3.3
PN-EN 303-5:2021-09 p. 5.9.3.4
PN-EN 303-5:2021-09 p. 5.9.3.5
PN-EN 303-5:2021-09 p. 5.9.3.6
PN-EN 303-5:2021-09 p. 5.9.4
PN-EN 303-5:2021-09 p. 5.9.4.4
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11079:2008
PN-EN ISO 11885:2009
PN-EN ISO 21877:2020-03
PN-EN ISO 22155:2016-07
PN-EN ISO 3746:2011 z wyłączeniem punktu 8.4
PN-EN ISO 3746:2011/Ap1:2017-09
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004+A1:2015-11
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 pkt.4 +Ap1:2010 + Ap2:2010
PN-EN ISO 6878:2006 pkt.8 +Ap1:2010 + Ap2:2010
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9377-2:2003
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 10396:2001
PN-ISO 11465:2026-03
PN-ISO 11466:2002
PN-ISO 13877:2004
PN-ISO 15705:2005
PN-ISO 16772:2009
PN-ISO 5667-10:2021-11 Procedura Badawcza PB-20 wydanie 8 z dnia 01.03.2022 r.
PN-ISO 7150-1:2002
PN-ISO 8288:2002 metoda A IR-106 wydanie 1 z dnia 05.11.2018 r. pkt.3.1.4
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04016-10:2005
PN-Z-04030-7:1994
PN-Z-04045-16:2010
PN-Z-04106-3:2002
PN-Z-04108-5:2006
PN-Z-04136-3:2003
PN-Z-04263-1:2012
PN-Z-04323:2004
PN-Z-04354:2005
PN-Z-04434:2011
PN-Z-04469:2015-10
PN-Z-04472:2015-10+Ap1:2015-12
PN-Z-04476:2016-10
PN-Z-04487:2017-10
PN-Z-04502:2019-10
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, str. 91-95
Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, str. 96-100
Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130
Podstawy i Metody Oceny Środowiska Pracy 2017 nr 2(92), str. 5-19
Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103), str. 157-170
Procedura Badawcza PB 52 wydanie 3 z dnia 28.08.2019 r.
Procedura Badawcza PB 54 wydanie 1 z dnia 15.05.2020 r.
Procedura Badawcza PB 58 wydanie 1 z dnia 16.04.2021 r.
Procedura Badawcza PB-01 wydanie 8 z dnia 24.06.2019 r.
Procedura Badawcza PB-13 wydanie 10 z dnia 18.09.2019 r.
Procedura Badawcza PB-14 wydanie 10 z dnia 18.09.2019 r.
Procedura Badawcza PB-23 wydanie 7 z dnia 24.06.2019 r.
Procedura Badawcza PB-37 wydanie 5 z dnia 24.06.2019 r.
Procedura Badawcza PB-51 wydanie 5 z dnia 10.06.2025 r.
Procedura Badawcza PB-55 wydanie 1 z dnia 10.09.2020 r.
Procedura Badawcza PB-57 wydanie 1 z dnia 16.04 2021 r.
Procedura Badawcza PB-59 wydanie 1 z dnia 01.03.2022 r.
Procedura Badawcza PB-60 wydanie 1 z dnia 01.03.2022 r.
Procedura Badawcza PB-61 wydanie 1 z dnia 03.03.2025 r.
Procedura Badawcza PB–22 wydanie 6 z dnia 24.06.2019 r.
Procedura Badawcza PB–53 wydanie 2 z dnia 07.07.2020 r.
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F