🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW PL

PCA AB 1298 • Skarżysko-Kamienna, Poland • 39 methods

Water & wastewaterMicrobiology

MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW is a laboratory accredited by PCA under number AB 1298 (Skarżysko-Kamienna, Poland). Its accreditation scope covers 39 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water Wastewater, Water Water intended for human consumption, Wastewater, Water intended for human consumption.

At a glance

  • Accreditation number: PCA AB 1298
  • Methods in scope: 39
  • Types of test objects: 6
  • City: Skarżysko-Kamienna, Poland
Accreditation number
AB 1298
Accreditation body
PCA
Address
I KANALIZACJI Sp. z o.o., ul. Cicha 8, 26-110 Skarżysko-Kamienna, LABORATORIUM BADANIA WODY I ŚCIEKÓW
City
Skarżysko-Kamienna, Poland

What this laboratory tests (6)

Accreditation scope — test methods (39)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.2
2 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
3 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
4 Water intended for human consumption Escherichia coli count Membrane filtration method
5 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
6 Water intended for human consumption Total microorganism count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
7 Water intended for human consumption Total microorganism count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
8 Water Water intended for human consumption Electrical conductivity Range: (20 − 3000) μS/cm Conductometric method PN-EN 27888:1999
9 Water Water intended for human consumption Turbidity Range: (0,30 − 400) NTU Nephelometric method PN-EN ISO 7027-1:2016-09 z wyłączeniem punktu 5.4
10 Water Water intended for human consumption Total calcium and magnesium content (total hardness) Range: (5 − 500) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
11 Water Water intended for human consumption Ammonium ion concentration Range: (0,05 − 1,5) mg/l Spectrophotometric method PN-ISO 7150-01:2002
12 Water Water intended for human consumption Nitrate concentration Range: (0,5 − 80) mg/l Spectrophotometric method PN-82/C-04576.08
13 Water Water intended for human consumption Nitrite concentration Range: (0,025 − 0,80) mg/l Spectrophotometric method PN-EN 26777:1999
14 Water Water intended for human consumption Colour Range: (5 − 70) mg/l Pt Visual method PN-EN ISO 7887:2012 | PN-EN ISO 7887:2012/Ap1:2015-06
15 Water Water intended for human consumption Colour Range: (2 − 100) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 | PN-EN ISO 7887:2012/Ap1:2015-06
16 Wastewater Sampling for chemical and physical testing Manual method Automatic method PN-ISO 5667-10:2021-11
17 Wastewater Nitrate nitrogen concentration Range: (0,2 − 50) mg/l Spectrophotometric method PN-82/C-04576.08
18 Wastewater Nitrite nitrogen concentration Range: (0,010 − 10) mg/l Spectrophotometric method PN-EN 26777:1999
19 Wastewater Ammonium nitrogen concentration Range: (0,04 − 4,00) mg/l Spectrophotometric method PN-ISO 7150-01:2002
20 Wastewater Ammonium nitrogen concentration Range: (0,4 − 1000) mg/l Titrimetric method PN-ISO 5664:2002
21 Water Water intended for human consumption, Wastewater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
22 Water Water intended for human consumption, Wastewater Iron concentration Range: (0,040 − 10,00) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
23 Water Water intended for human consumption, Wastewater Manganese concentration Range: (0,030 − 4,00) mg/l Spectrophotometric method PN-92/C-04590.03
24 Water Water intended for human consumption, Wastewater Chloride concentration Range: (5,0 − 400) mg/l Titrimetric method ISO 9297:1994
25 Water Wastewater Orthophosphate concentration Range: (0,040 − 40,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+ Ap2:2010
26 Water Wastewater Total phosphorus concentration Range: (0,040 − 80,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010
27 Water Wastewater Chemical oxygen demand - COD-Cr Range: (7,0 – 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
28 Water Wastewater Chemical oxygen demand - COD-Cr Range: (30 – 10000) mg/l O 2 Titrimetric method PN-ISO 6060:2006
29 Water Wastewater Biochemical oxygen demand – BOD 5 Range: (3,0 − 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
30 Water Wastewater Biochemical oxygen demand – BOD 5 Range: (0,50 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
31 Water Wastewater Biochemical oxygen demand – BOD 5 Range: (3,0− 6000) mg/l O 2 Titrimetric method PN-EN ISO 5815-1:2019-12
32 Water Wastewater Biochemical oxygen demand – BOD 5 Range: (0,50 – 6,0) mg/l O 2 Titrimetric method PN-EN 1899-2:2002
33 Water Wastewater Biochemical oxygen demand – BOD 5 Range: (1,0 − 6000) mg/l O 2 Optical method PN-EN ISO 5815-1:2019-12
34 Water Wastewater Total suspended solids (TSS) Range: (2,0 − 1000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
35 Wastewater Kjeldahl nitrogen concentration Range: (2,0 − 1000) mg/l Titrimetric method PN-EN 25663:2001
36 Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
37 Sewage sludge pH Range: 2,0 – 12,0 Potentiometric method PN-EN 12176:2004
38 Sewage sludge Dry residue / water content Range: (1,0 – 99,0) % Gravimetric method PN-EN 12880:2004
39 Sewage sludge Loss on ignition / residue on ignition Range: (10,0 – 80,0) % Gravimetric method PN-EN 12879:2004

Reference standards (31)

ISO 9297:1994
PN-73/C-04576/14
PN-82/C-04576.08
PN-92/C-04590.03
PN-EN 12176:2004
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 +Ap1:2010+ Ap2:2010
PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010
PN-EN ISO 7027-1:2016-09 z wyłączeniem punktu 5.4
PN-EN ISO 7887:2012
PN-EN ISO 7887:2012/Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-01:2002