🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW PL
Water & wastewaterMicrobiology
MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW is a laboratory accredited by PCA under number AB 1298 (Skarżysko-Kamienna, Poland). Its accreditation scope covers 39 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water Wastewater, Water Water intended for human consumption, Wastewater, Water intended for human consumption.
At a glance
- Accreditation number: PCA AB 1298
- Methods in scope: 39
- Types of test objects: 6
- City: Skarżysko-Kamienna, Poland
- Accreditation number
- AB 1298
- Accreditation body
- PCA
- Address
- I KANALIZACJI Sp. z o.o., ul. Cicha 8, 26-110 Skarżysko-Kamienna, LABORATORIUM BADANIA WODY I ŚCIEKÓW
- City
- Skarżysko-Kamienna, Poland
What this laboratory tests (6)
- Water Wastewater — 10 methods
- Water Water intended for human consumption — 8 methods
- Wastewater — 7 methods
- Water intended for human consumption — 7 methods
- Water Water intended for human consumption, Wastewater — 4 methods
- Sewage sludge — 3 methods
Accreditation scope — test methods (39)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.2 | ||
| 2 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 3 | Water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 4 | Water intended for human consumption | Escherichia coli count Membrane filtration method | |||
| 5 | Water intended for human consumption | Intestinal enterococci count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 6 | Water intended for human consumption | Total microorganism count at 22 °C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 7 | Water intended for human consumption | Total microorganism count at 36 °C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 8 | Water Water intended for human consumption | Electrical conductivity Range: (20 − 3000) μS/cm Conductometric method | PN-EN 27888:1999 | ||
| 9 | Water Water intended for human consumption | Turbidity Range: (0,30 − 400) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 z wyłączeniem punktu 5.4 | ||
| 10 | Water Water intended for human consumption | Total calcium and magnesium content (total hardness) Range: (5 − 500) mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 11 | Water Water intended for human consumption | Ammonium ion concentration Range: (0,05 − 1,5) mg/l Spectrophotometric method | PN-ISO 7150-01:2002 | ||
| 12 | Water Water intended for human consumption | Nitrate concentration Range: (0,5 − 80) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 13 | Water Water intended for human consumption | Nitrite concentration Range: (0,025 − 0,80) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 14 | Water Water intended for human consumption | Colour Range: (5 − 70) mg/l Pt Visual method | PN-EN ISO 7887:2012 | PN-EN ISO 7887:2012/Ap1:2015-06 | ||
| 15 | Water Water intended for human consumption | Colour Range: (2 − 100) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 | PN-EN ISO 7887:2012/Ap1:2015-06 | ||
| 16 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method | PN-ISO 5667-10:2021-11 | ||
| 17 | Wastewater | Nitrate nitrogen concentration Range: (0,2 − 50) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 18 | Wastewater | Nitrite nitrogen concentration Range: (0,010 − 10) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 19 | Wastewater | Ammonium nitrogen concentration Range: (0,04 − 4,00) mg/l Spectrophotometric method | PN-ISO 7150-01:2002 | ||
| 20 | Wastewater | Ammonium nitrogen concentration Range: (0,4 − 1000) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 21 | Water Water intended for human consumption, Wastewater | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 22 | Water Water intended for human consumption, Wastewater | Iron concentration Range: (0,040 − 10,00) mg/l Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | ||
| 23 | Water Water intended for human consumption, Wastewater | Manganese concentration Range: (0,030 − 4,00) mg/l Spectrophotometric method | PN-92/C-04590.03 | ||
| 24 | Water Water intended for human consumption, Wastewater | Chloride concentration Range: (5,0 − 400) mg/l Titrimetric method | ISO 9297:1994 | ||
| 25 | Water Wastewater | Orthophosphate concentration Range: (0,040 − 40,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 +Ap1:2010+ Ap2:2010 | ||
| 26 | Water Wastewater | Total phosphorus concentration Range: (0,040 − 80,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 | ||
| 27 | Water Wastewater | Chemical oxygen demand - COD-Cr Range: (7,0 – 10000) mg/l O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 28 | Water Wastewater | Chemical oxygen demand - COD-Cr Range: (30 – 10000) mg/l O 2 Titrimetric method | PN-ISO 6060:2006 | ||
| 29 | Water Wastewater | Biochemical oxygen demand – BOD 5 Range: (3,0 − 6000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 30 | Water Wastewater | Biochemical oxygen demand – BOD 5 Range: (0,50 – 6,0) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 31 | Water Wastewater | Biochemical oxygen demand – BOD 5 Range: (3,0− 6000) mg/l O 2 Titrimetric method | PN-EN ISO 5815-1:2019-12 | ||
| 32 | Water Wastewater | Biochemical oxygen demand – BOD 5 Range: (0,50 – 6,0) mg/l O 2 Titrimetric method | PN-EN 1899-2:2002 | ||
| 33 | Water Wastewater | Biochemical oxygen demand – BOD 5 Range: (1,0 − 6000) mg/l O 2 Optical method | PN-EN ISO 5815-1:2019-12 | ||
| 34 | Water Wastewater | Total suspended solids (TSS) Range: (2,0 − 1000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 35 | Wastewater | Kjeldahl nitrogen concentration Range: (2,0 − 1000) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 36 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 37 | Sewage sludge | pH Range: 2,0 – 12,0 Potentiometric method | PN-EN 12176:2004 | ||
| 38 | Sewage sludge | Dry residue / water content Range: (1,0 – 99,0) % Gravimetric method | PN-EN 12880:2004 | ||
| 39 | Sewage sludge | Loss on ignition / residue on ignition Range: (10,0 – 80,0) % Gravimetric method | PN-EN 12879:2004 | ||
Reference standards (31)
ISO 9297:1994
PN-73/C-04576/14
PN-82/C-04576.08
PN-92/C-04590.03
PN-EN 12176:2004
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 +Ap1:2010+ Ap2:2010
PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010
PN-EN ISO 7027-1:2016-09 z wyłączeniem punktu 5.4
PN-EN ISO 7887:2012
PN-EN ISO 7887:2012/Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-01:2002