🇵🇱 SAYBOLT POLAND Sp. z o.o. PL
Petrochemistry & fuelsMaterials & polymersWater & wastewater
SAYBOLT POLAND Sp. z o.o. is a laboratory accredited by PCA under number AB 1278 (Gdynia, Poland). Its accreditation scope covers 47 test methods in the following areas: Petrochemistry & fuels, Materials & polymers, Water & wastewater. Test objects include: Gaseous fuels E: liquefied petroleum gases, LPG, Crude oil E, Liquid fuels: diesel fuel, Liquid fuels: unleaded petrol, Other petroleum products: petrol com…. Most frequently used techniques: Gravimetric method, Optical method, Potentiometric titration method.
At a glance
- Accreditation number: PCA AB 1278
- Methods in scope: 47
- Types of test objects: 28
- Techniques used: 18
- City: Gdynia, Poland
- Accreditation number
- AB 1278
- Accreditation body
- PCA
- Address
- LABORATORIUM CHEMICZNE SAYBOLT POLAND, ul. Podlaska 1, 81-325 Gdynia
- City
- Gdynia, Poland
What this laboratory tests (28)
- Gaseous fuels E: liquefied petroleum gases, LPG — 11 methods
- Crude oil E — 8 methods
- Liquid fuels: diesel fuel — 2 methods
- Liquid fuels: unleaded petrol, Other petroleum products: petrol components — 2 methods
- Gaseous fuels: liquefied petroleum gases, LPG — 1 method
- Liquid fuels E: diesel fuel — 1 method
- Liquid fuels E: diesel fuel, light heating oil, heavy heating oil — 1 method
- Liquid fuels E: diesel fuel, marine fuel — 1 method
- Liquid fuels E: heavy heating oil — 1 method
- Materiały smarne E: oleje bazowe, Paliwa ciekłe E: olej napędowy, paliwo żeglugowe, olej opałowy ciężki — 1 method
- Materiały smarne E: oleje bazowe, Paliwa ciekłe E: olej opałowy ciężki — 1 method
- Paliwa ciekłe E: benzyna bezołowiowa, olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe E: destylaty naftowe — 1 method
- Paliwa ciekłe E: benzyna bezołowiowa, olej napędowy, biopaliwa ciekłe: parafinowy olej napędowy (HVO), Inne przetwory naftowe E: destylaty naftowe — 1 method
- Paliwa ciekłe E: olej napędowy, paliwo żeglugowe, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), parafinowy olej napędowy (HVO) — 1 method
- Paliwa ciekłe E: olej napędowy, paliwo żeglugowe, olej opałowy ciężki, olej popirolityczny, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) — 1 method
- and 13 more
Analytical techniques used (18)
- Gravimetric method — 4 methods
- Optical method — 4 methods
- Potentiometric titration method — 4 methods
- Visual method — 4 methods
- Distillation method — 3 methods
- Gas chromatography with flame ionization detection (GC-FID) — 3 methods
- Coulometric titration method — 2 methods
- Energy-dispersive X-ray fluorescence spectrometry (ED-XRF) — 2 methods
- Oscillation method — 2 methods
- Capillary method — 1 method
- Conductometric method — 1 method
- Flame atomic absorption spectrometry (FAAS) — 1 method
- Metoda rentgenowskiej spektrometrii fluorescencyjnej z dyspersją energii (ED-XRF) — 1 method
- Organoleptic method — 1 method
- Pensky-Martens closed cup method — 1 method
- and 3 more
Laboratory sections (2)
- Laboratorium Chemiczne Saybolt Poland — 35 methods
- Laboratorium Chemiczne Saybolt Poland, Oddział Gdańsk — 12 methods
Laboratory locations
- LABORATORIUM CHEMICZNE SAYBOLT POLAND — ul. Podlaska 1, 81-325 Gdynia
- Laboratorium Chemiczne Saybolt Poland, Oddział Gdańsk — ul. Budowniczych Portu Północnego 23, 80-601 Gdańsk
Accreditation scope — test methods (47)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium Chemiczne Saybolt Poland | |||||
| 1 | Ropa naftowa E, Materiały smarne E: oleje bazowe, Paliwa ciekłe E, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), parafinowy olej napędowy (HVO), Inne przetwory naftowe E: destylaty naftowe, pozostałość próżniowa | Density Range (600,0 – 1100) kg/m3 Range (0,6000 – 1,100) g/cm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Oscillation method | PN-EN ISO 12185 | |
| 2 | Crude oil E | Density Range (750,0 – 950,0) kg/m3 Range (0,7500 – 0,9500) g/cm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Oscillation method | ASTM D 5002 | |
| 3 | Crude oil E | Water content Range (0,02 – 1,50) % (m/m) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Coulometric titration method | ASTM D 4928 | |
| 4 | Crude oil E | Water content Range (0,025 – 1,000) % (v/v) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Distillation method | ASTM D 4006 | |
| 5 | Crude oil E | Chloride salt content Range (1,0 – 50,0) mg/dm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric titration method | GOST 21534 metoda A | |
| 6 | Crude oil E | Content of water and impurities (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
ASTM D 7829 | ||
| 7 | Crude oil E | API density (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
ASTM D 5002 | ||
| 8 | Crude oil E | Pour point Range (-36)°C – 0°C Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Optical method | ASTM D 5853 metoda A | |
| 9 | Crude oil E | Chloride salt content Range (3 – 430) mg/dm3 Zawartość soli chlorkowych mg/kg (z obliczeń) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Conductometric method | ASTM D 3230 | |
| 10 | Ropa naftowa E, Materiały smarne E: oleje bazowe, Paliwa ciekłe E, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) | Lepkość kinematyczna w temp. 20 °C, 40°C, 50°C, 100 °C Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Capillary method | PN-EN ISO 3104 | |
| 11 | Liquid fuels E: diesel fuel, light heating oil, heavy heating oil | Residue after incineration Range (0,001 – 0,180) % (m/m) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN ISO 6245 | |
| 12 | Materiały smarne E: oleje bazowe, Paliwa ciekłe E: olej opałowy ciężki | Water content Range (0,05 – 5,00) % (v/v) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Distillation method | ASTM D 95 | |
| 13 | Paliwa ciekłe E: benzyna bezołowiowa, olej napędowy, biopaliwa ciekłe: parafinowy olej napędowy (HVO), Inne przetwory naftowe E: destylaty naftowe | Fractional composition Range (26,0 – 362,0) °C Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Distillation method | PN-EN ISO 3405 z wyłączeniem pkt. 9 | |
| 14 | Ropa naftowa E, Materiały smarne E: oleje bazowe, Paliwa ciekłe E: benzyna bezołowiowa, olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) | Water content Range (0,003 – 0,100) % (m/m) Range (30 – 1000) mg/kg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Coulometric titration method | PN-EN ISO 12937 | |
| 15 | Paliwa ciekłe E: olej napędowy, paliwo żeglugowe, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), parafinowy olej napędowy (HVO) | Cloud point Range ((-31) – 20) °C Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Optical method | PN-EN ISO 3015 | |
| 16 | Liquid fuels E: diesel fuel, marine fuel | Cetane index (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN ISO 4264 | ||
| 17 | Paliwa ciekłe E: olej opałowy lekki, olej opałowy ciężki, olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) | Flash point Range (40,0 – 320,0) °C Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Pensky-Martens closed cup method | PN-EN ISO 2719 | ASTM D 93 | |
| 18 | Paliwa ciekłe E: benzyna bezołowiowa, olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe E: destylaty naftowe | Sulfur content Range (5,0 – 500) mg/kg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF) | PN-EN ISO 20884 | |
| 19 | Paliwa ciekłe E: olej napędowy, paliwo żeglugowe, olej opałowy ciężki, olej popirolityczny, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) | Pour point Range (-30) °C – 20 °C Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Optical method | PN-EN ISO 3016 | |
| 20 | Paliwa ciekłe E: olej opałowy lekki, paliwo żeglugowe, olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), parafinowy olej napędowy (HVO) | Cold filter plugging point (CFPP) Range (-35) °C – 0 °C Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Optical method | PN-EN 116 | |
| 21 | Ropa naftowa E, Materiały smarne E: oleje bazowe, Paliwa ciekłe E: olej opałowy ciężki | Acid value Range (0,05 – 1,00) mg KOH/g Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric titration method | ASTM D 664 | |
| 22 | Ropa naftowa E, Materiały smarne E: oleje bazowe, Paliwa ciekłe E | Sulfur content Range (0,030 – 5,00) % (m/m) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Metoda rentgenowskiej spektrometrii fluorescencyjnej z dyspersją energii (ED-XRF) | PN-EN ISO 8754 | |
| 23 | Materiały smarne E: oleje bazowe, Paliwa ciekłe E: olej napędowy, paliwo żeglugowe, olej opałowy ciężki | Zawartość pozostałości po koksowaniu Range (0,03 – 30,00) % (m/m) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN ISO 10370 | |
| 24 | Liquid fuels E: heavy heating oil | Element content Aluminium (5 – 150) mg/kg Silicon (10 – 250) mg/kg Vanadium (1 – 400) mg/kg Iron (2 – 60) mg/kg Calcium (3 – 100) mg/kg Zinc (1 – 70) mg/kg Sodium (1 – 100) mg/kg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame atomic absorption spectrometry (FAAS) | IP 470 | |
| 25 | Ropa naftowa E, Materiały smarne E: oleje bazowe, Paliwa ciekłe E: olej opałowy ciężki, olej popirolityczny | Sulfur content Range (0,030 – 5,00) % (m/m) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Energy-dispersive X-ray fluorescence spectrometry (ED-XRF) | ASTM D 4294 | |
| 26 | Ropa naftowa E, Paliwa ciekłe E: olej popirolityczny | Impurity content Range (0,01 – 0,05) % (m/m) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | ASTM D 473 | |
| 27 | Ropa naftowa E, Inne przetwory naftowe E: destylaty naftowe | Content of organic chlorides in the fraction boiling up to 204°C Range (1 – 200) mg/kg Organic chloride content in crude oil (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric titration method | ASTM D 4929 metoda A | |
| 28 | Liquid fuels E: diesel fuel | Impurity content Range (12,0 – 30,0) mg/kg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 12662-1 | |
| 29 | Ropa naftowa E, Paliwa ciekłe E: benzyna bezołowiowa, nafta, olej napędowy, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) | Sampling from tanks for chemical and physical testing Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN ISO 3170 z wyłączeniem pkt. 8.3.1.3, 8.3.1.4, 8.3.1.5, 8.3.1.6, 8.3.1.8, 8.3.2, 8.4, 8.7, 8.8 | ||
| 30 | Ropa naftowa, Materiały smarne: oleje bazowe, Paliwa ciekłe: olej opałowy ciężki | Sulfur content Range (0,030 – 5,000) % (m/m) |
Energy-dispersive X-ray fluorescence spectrometry (ED-XRF) | GOST R 51947-2002 | |
| 31 | Ropa naftowa, Inne przetwory naftowe: destylaty naftowe | Content of organic chlorides in the fraction boiling up to 204°C Range (1 – 200) mg/kg Organic chloride content in crude oil (calculated) |
Potentiometric titration method | GOST R 52247-2021 metoda A | |
| 32 | Liquid fuels: diesel fuel | Copper strip corrosion corrosion class (1 – 4) |
Visual method | PN-EN ISO 2160:2004 | |
| 33 | Liquid fuels: diesel fuel | Fatty acid methyl ester FAME content Range (0,05 – 20,0) %(v/v) |
Spectrometry method in the infrared range (IR) | PN-EN 14078:2014-06 | |
| 34 | Liquid fuels: unleaded petrol, Other petroleum products: petrol components | Benzene content Range (0,05 – 6,0) %(v/v) |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 12177:2023-04 | |
| 35 | Liquid fuels: unleaded petrol, Other petroleum products: petrol components | Content of oxygenated organic compounds Range (0,17 – 15,0) % (v/v) Całkowita zawartości organicznie związanego tlenu (z obliczeń) |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13132:2005 | |
| Laboratorium Chemiczne Saybolt Poland, Oddział Gdańsk | |||||
| 36 | Gaseous fuels: liquefied petroleum gases, LPG | Sampling for chemical and physical testing (including sensory testing) | PN-EN ISO 4257:2004 | ||
| 37 | Gaseous fuels E: liquefied petroleum gases, LPG | Presence of hydrogen sulfide Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Visual method | PN-EN ISO 8819 | |
| 38 | Gaseous fuels E: liquefied petroleum gases, LPG | Sulfur content Range (1,0 – 50,0) mg/kg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ultraviolet fluorescence method | PN-EN 17178 | |
| 39 | Gaseous fuels E: liquefied petroleum gases, LPG | Copper strip corrosion corrosion class (1 – 4) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Visual method | PN-EN ISO 6251 | |
| 40 | Gaseous fuels E: liquefied petroleum gases, LPG | Presence of water Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Visual method | PN-EN 15469 | |
| 41 | Gaseous fuels E: liquefied petroleum gases, LPG | Odour Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Organoleptic method | PN-EN 589 załącznik A | |
| 42 | Gaseous fuels E: liquefied petroleum gases, LPG | Motor octane number (MON) (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 589 załącznik B | ||
| 43 | Gaseous fuels E: liquefied petroleum gases, LPG | Density at 15°C (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN ISO 8973 | ||
| 44 | Gaseous fuels E: liquefied petroleum gases, LPG | Temperature at which the estimated relative vapour pressure is not less than 150 kPa (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN ISO 8973 | PN-EN 589 załącznik C | ||
| 45 | Gaseous fuels E: liquefied petroleum gases, LPG | Vapour pressure estimated at temperatures: 37,8°C, 40°C, 50°C, 70°C (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN ISO 8973 | ||
| 46 | Gaseous fuels E: liquefied petroleum gases, LPG | Vapour pressure estimated at temperatures: -10°C, -5°C, 0°C, 10°C, 20°C, 40°C (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 589 załącznik C | ||
| 47 | Gaseous fuels E: liquefied petroleum gases, LPG | Skład węglowodorowy C1-C5 i dienów Range (0,1 – 100,0) % (m/m) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 27941 | |
Reference standards (45)
ASTM D 3230
ASTM D 4006
ASTM D 4294
ASTM D 473
ASTM D 4928
ASTM D 4929 metoda A
ASTM D 5002
ASTM D 5853 metoda A
ASTM D 664
ASTM D 7829
ASTM D 93
ASTM D 95
GOST 21534 metoda A
GOST R 51947-2002
GOST R 52247-2021 metoda A
IP 470
PN-EN 116
PN-EN 12177:2023-04
PN-EN 12662-1
PN-EN 13132:2005
PN-EN 14078:2014-06
PN-EN 15469
PN-EN 17178
PN-EN 27941
PN-EN 589 załącznik A
PN-EN 589 załącznik B
PN-EN 589 załącznik C
PN-EN ISO 10370
PN-EN ISO 12185
PN-EN ISO 12937
PN-EN ISO 20884
PN-EN ISO 2160:2004
PN-EN ISO 2719
PN-EN ISO 3015
PN-EN ISO 3016
PN-EN ISO 3104
PN-EN ISO 3170 z wyłączeniem pkt. 8.3.1.3, 8.3.1.4, 8.3.1.5, 8.3.1.6, 8.3.1.8, 8.3.2, 8.4, 8.7, 8.8
PN-EN ISO 3405 z wyłączeniem pkt. 9
PN-EN ISO 4257:2004
PN-EN ISO 4264
PN-EN ISO 6245
PN-EN ISO 6251
PN-EN ISO 8754
PN-EN ISO 8819
PN-EN ISO 8973