🇵🇱 WAVIN POLSKA S.A. PL
Materials & polymersConstruction
WAVIN POLSKA S.A. is a laboratory accredited by PCA under number AB 1256 (Buk, Poland). Its accreditation scope covers 31 test methods in the following areas: Materials & polymers, Construction. Test objects include: Thermoplastic pipes with a maximum diameter of 1200 mm, Plastic pipes, fittings and other plastic products, Construction products, materials, works, Plastic and rubber products, Construction products, plastic products Tiles with a maximum thickn….
At a glance
- Accreditation number: PCA AB 1256
- Methods in scope: 31
- Types of test objects: 27
- City: Buk, Poland
- Accreditation number
- AB 1256
- Accreditation body
- PCA
- Address
- LABORATORIUM ZAKŁADOWE, ul. Dobieżyńska 43, 64-320 Buk
- City
- Buk, Poland
What this laboratory tests (27)
- Thermoplastic pipes with a maximum diameter of 1200 mm — 4 methods
- Plastic pipes, fittings and other plastic products — 2 methods
- Construction products, materials, works, Plastic and rubber products — 1 method
- Construction products, plastic products Tiles with a maximum thickness of 6 mm — 1 method
- Construction products, thermoplastic products — 1 method
- Fabricated thermoplastic fittings with a maximum diameter of 2000 mm — 1 method
- Injection-moulded thermoplastic fittings with a maximum sample dimension of 500x500x500 mm — 1 method
- Non-porous plastics — 1 method
- Plastics pipes and fittings with a maximum diameter of 3000 mm — 1 method
- Plastics pipes, fittings, construction materials and products — 1 method
- Plastics piping systems with a maximum diameter of 1100 mm — 1 method
- Plastics piping systems with a maximum diameter of 160 mm — 1 method
- Plastics piping systems with a maximum diameter of 2000 mm — 1 method
- Plastics piping systems with a maximum diameter of 315 mm — 1 method
- Polyolefin pipes and fittings — 1 method
- and 12 more
Accreditation scope — test methods (31)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Plastic pipes, fittings and other plastic products | Surface condition, colour Visual method | PN-EN 13018:2016-04 z wyłączeniem Rozdziału 6 | ||
| 2 | Plastics pipes and fittings with a maximum diameter of 3000 mm | Geometric dimensions, including diameter, wall thickness, length, angles | PN-EN ISO 3126:2006 | ||
| 3 | Thermoplastics pipes with a maximum diameter of 500 mm | Longitudinal shrinkage Temperature max. 150ºC | PN-EN ISO 2505:2024-04 | ||
| 4 | Thermoplastics pipes, fittings and assemblies with a maximum diameter of 250 mm | Resistance to internal pressure Temperature range: (20 – 95)ºC Pressure max. 100 bar Water-in-water and water-in-air method | PN-EN ISO 1167-1:2007 PN-EN ISO 1167-2:2007 PN-EN ISO 1167-3:2008 PN-EN ISO 1167-4:2008 | ||
| 5 | Thermoplastic pipes | Tensile mechanical properties: - elongation at break - elongation at yield - yield stress - tensile strength Static tensile test. Specimen load: (25 – 30000) N | PN-EN ISO 6259-1:2015-05 PN-EN ISO 6259-2:2021-03 PN-EN ISO 6259-3:2015-08 | ||
| 6 | Thermoplastic pipes with a maximum diameter of 1200 mm | Ring stiffness Specimen load: (25 – 30000) N | PN-EN ISO 9969:2016-02 | ||
| 7 | Thermoplastic pipes with a maximum diameter of 1200 mm | Ring flexibility Specimen load: (25 – 30000) N | PN-EN ISO 9969:2016-02 PN-EN ISO 13968:2009 | ||
| 8 | Thermoplastics shaft pipes with diameters from 200 mm to 1000 mm | Ring stiffness Load: (25 – 30000) N | PN-EN ISO 13268:2023-07 PN-EN ISO 9969:2016-02 | ||
| 9 | Unplasticized polyvinyl chloride pipes with a maximum diameter of 500 mm | Resistance to dichloromethane | PN-EN 580:2005 PN-EN ISO 9852:2017-11 | ||
| 10 | Thermoplastic pipes with a maximum diameter of 1200 mm | Resistance to external blows Falling weight method Temperature: 0ºC and 23ºC | PN-EN 744:1997 PN-EN ISO 3127:2017-12 | ||
| 11 | Thermoplastic fittings with maximum sample dimensions of 2000x1000x1000 | Impact resistance | PN-EN 12061:2001 PN-EN ISO 13263:2017-12 | ||
| 12 | Fabricated thermoplastic fittings with a maximum diameter of 2000 mm | Mechanical strength or flexibility Static bending test Maximum load 10000 N | PN-EN 12256:2001+Ap1:2002 PN-EN ISO 13264:2017-12 | ||
| 13 | Injection-moulded thermoplastic fittings with a maximum sample dimension of 500x500x500 mm | Changes after heating Visual method Method A – heating in air Maximum temperature 200ºC | PN-EN ISO 580:2006 | ||
| 14 | Plastics piping systems with a maximum diameter of 160 mm | Resistance to cyclic exposure to elevated temperature | PN-EN 1055:1998 PN-EN ISO 13257:2019-01 | ||
| 15 | Plastics piping systems with a maximum diameter of 315 mm | Tightness of joints of internal drainage pipe systems Air test method | PN-EN 1054:1998 PN-EN ISO 13255:2017-12 | ||
| 16 | Plastics piping systems with a maximum diameter of 2000 mm | Tightness of joints Water test method | PN-EN 1053:1998 PN-EN ISO 13254:2017-11 | ||
| 17 | Plastics piping systems with a maximum diameter of 1100 mm | Tightness of socket joints with an elastomeric sealing ring Pressure drop measurement | PN-EN 1277:2005 PN-EN ISO 13259:2021-01 | ||
| 18 | Thermoplastic pipes with a maximum diameter of 1200 mm | Resistance to external blows Staircase method at temp. -10ºC, 0ºC and 23ºC | PN-EN 1411:1998 PN-EN ISO 11173:2017-12 | ||
| 19 | Construction products, plastic products Tiles with a maximum thickness of 6 mm | Resistance to accelerated ageing Tiles with a maximum thickness of 6 mm Exposure to light from UV-A 351 fluorescent lamps without water spray | PN-EN ISO 4892-1:2025-04 PN-EN ISO 4892-3:2025-04 | ||
| 20 | Non-porous plastics | Density Immersion method Range: (0,3 – 2) g/cm3 | EN ISO 1183-1:2025 | ||
| 21 | Polyolefins and polyolefin pipes and fittings | Oxidation induction time (OIT) Differential scanning calorimetry (DSC) method | PN-EN 728:1999 EN ISO 11357-6:2025 | ||
| 22 | Thermoplastics and thermoplastic products | Melt mass-flow rate and melt volume-flow rate Load range: (2,16 – 21,6) kg Maximum temperature 300ºC | PN-EN ISO 1133-1:2022-12 | ||
| 23 | Thermoplastic products | Vicat softening temperature Temperature range: (50 – 150)ºC Method using a heating liquid | PN-EN 727:1998 PN-EN ISO 306:2023-05 PN-EN ISO 2507-1:2017-11 PN-EN ISO 2507-2:2017-12 PN-EN ISO 2507-3:2017-12 | ||
| 24 | Polyolefin pipes and fittings | Degree of dispersion of pigment or carbon black | ISO 18553:2025 | ||
| 25 | Thermoplastics Plastic pipes and fittings | Ash content Range: (0,01 – 70,00)% Gravimetric method | PN-EN ISO 3451-1:2019-04 Metoda A | ||
| 26 | Thermoplastics pipes with a maximum diameter of 1000 mm | Creep ratio of pipes | PN-EN ISO 9967:2016-02 | ||
| 27 | Structured-wall thermoplastics pipes with a maximum diameter of 1200 mm | Changes after heating Visual method Method A – heating in air Maximum temperature 200ºC | PN-ISO 12091:2009 | ||
| 28 | Plastic pipes, fittings and other plastic products | Colour change according to the grey scale | PN-EN 20105-A02:1996 | ||
| 29 | Plastics pipes, fittings, construction materials and products | Colour measurement Colorimetric method | PN-ISO 7724-1:2003 PN-ISO 7724-2:2003 PN-ISO 7724-3:2003 | ||
| 30 | Construction products, thermoplastic products | Short-term compressive strength of boxes Maximum load 600 kN | PN-EN 17150:2019-11 | ||
| 31 | Construction products, materials, works, Plastic and rubber products | Durability | PN-EN 13598-2:2020-11 Załącznik A | ||
Reference standards (31)
EN ISO 1183-1:2025
ISO 18553:2025
PN-EN 1053:1998 PN-EN ISO 13254:2017-11
PN-EN 1054:1998 PN-EN ISO 13255:2017-12
PN-EN 1055:1998 PN-EN ISO 13257:2019-01
PN-EN 12061:2001 PN-EN ISO 13263:2017-12
PN-EN 12256:2001+Ap1:2002 PN-EN ISO 13264:2017-12
PN-EN 1277:2005 PN-EN ISO 13259:2021-01
PN-EN 13018:2016-04 z wyłączeniem Rozdziału 6
PN-EN 13598-2:2020-11 Załącznik A
PN-EN 1411:1998 PN-EN ISO 11173:2017-12
PN-EN 17150:2019-11
PN-EN 20105-A02:1996
PN-EN 580:2005 PN-EN ISO 9852:2017-11
PN-EN 727:1998 PN-EN ISO 306:2023-05 PN-EN ISO 2507-1:2017-11 PN-EN ISO 2507-2:2017-12 PN-EN ISO 2507-3:2017-12
PN-EN 728:1999 EN ISO 11357-6:2025
PN-EN 744:1997 PN-EN ISO 3127:2017-12
PN-EN ISO 1133-1:2022-12
PN-EN ISO 1167-1:2007 PN-EN ISO 1167-2:2007 PN-EN ISO 1167-3:2008 PN-EN ISO 1167-4:2008
PN-EN ISO 13268:2023-07 PN-EN ISO 9969:2016-02
PN-EN ISO 2505:2024-04
PN-EN ISO 3126:2006
PN-EN ISO 3451-1:2019-04 Metoda A
PN-EN ISO 4892-1:2025-04 PN-EN ISO 4892-3:2025-04
PN-EN ISO 580:2006
PN-EN ISO 6259-1:2015-05 PN-EN ISO 6259-2:2021-03 PN-EN ISO 6259-3:2015-08
PN-EN ISO 9967:2016-02
PN-EN ISO 9969:2016-02
PN-EN ISO 9969:2016-02 PN-EN ISO 13968:2009
PN-ISO 12091:2009
PN-ISO 7724-1:2003 PN-ISO 7724-2:2003 PN-ISO 7724-3:2003