🇵🇱 PIT-RADWAR SPÓŁKA AKCYJNA PL

PCA AB 1218 • Warszawa, Poland • 30 methods

Electronics & EMCEnvironment

PIT-RADWAR SPÓŁKA AKCYJNA is a laboratory accredited by PCA under number AB 1218 (Warszawa, Poland). Its accreditation scope covers 30 test methods in the following areas: Electronics & EMC, Environment. Test objects include: Electrical, telecommunications and electronic products and equipmen…, Environment – electromagnetic field in the vicinity of radar and ra…, Environment – electromagnetic field in the vicinity of radiocommuni…. Most frequently used techniques: Direct measurement method, Direct measurement method, Metoda pomiarowa pośrednia.

At a glance

  • Accreditation number: PCA AB 1218
  • Methods in scope: 30
  • Types of test objects: 3
  • Techniques used: 4
  • City: Warszawa, Poland
Accreditation number
AB 1218
Accreditation body
PCA
Address
ul. Poligonowa 30, 04-051 Warszawa
City
Warszawa, Poland

What this laboratory tests (3)

Analytical techniques used (4)

Laboratory locations

Accreditation scope — test methods (30)

No. Test object Methodology / Parameters Technique Reference document
Dział Laboratoriów Akredytowanych
1 Electrical, telecommunications and electronic products and equipment; military equipment. Charakterystyki promieniowania anten i systemów antenowych:
charakterystyki dookolne szerokość listka głównego poziom listków bocznych średni poziom listków bocznych położenie listków bocznych Frequency range (0,1 - 18) GHz.
Direct measurement method. ANSI/IEEE Std 149:1979 (R2008)
2 Electrical, telecommunications and electronic products and equipment; military equipment. Zysk energetyczny anteny:
Frequency range (0,75 - 18) GHz.
Direct measurement method. ANSI/IEEE Std 149:1979 (R2008)
3 Electrical, telecommunications and electronic products and equipment; military equipment. Kąt położenia osi elektrycznej anteny względem określonej płaszczyzny
Frequency range (0,1 - 18) GHz.
Direct measurement method. ANSI/IEEE Std 149:1979 (R2008)
4 Electrical, telecommunications and electronic products and equipment; military equipment. Współczynnik fali stojącej (WFS) i współczynnik transmisji macierzy roz-proszenia.
Frequency range (100 kHz – 20 GHz).
Direct measurement method. PB-05 wydanie D z dnia 17.04.2024 r.
5 Electrical, telecommunications and electronic products and equipment; military equipment. Tłumienność obiektów ekranujących.
Frequency range 10 kHz – 18 GHz.
Metoda pomiarowa pośrednia. PB-06 wydanie E z dnia 12.04.2022 r. | NO-06-A501:2009 | NO-06-A501:2009/A1:2018
6 Electrical, telecommunications and electronic products and equipment; military equipment. Tłumienność ekranu pomieszczeń ekra-nujących w zakresie częstotliwości 10 kHz do 18 GHz. Direct measurement method PN-EN 50147-1:2000
7 Electrical, telecommunications and electronic products and equipment; military equipment. Kompatybilność elektromagnetyczna (EMC). Badanie skuteczności ekranowania elektromagnetycznego pustych obudów mechanicznych. Stopnie ochrony przed zaburzeniami elektromagnetycznymi zapewniane przez obudowy (kod EM)
Frequency range 10kHz – 10 GHz
Metoda pomiarowa pośrednia PN-EN 61000-5-7:2005 | EN 61000-5-7:2001
8 Electrical, telecommunications and electronic products and equipment; military equipment. Emisja zaburzeń elektromagnetycznych przewodzonych w przewodach zasilania urządzenia w zakresie częstotliwości od 10 kHz do 10 MHz. Direct measurement method NO-06-A500:2012 pkt. 3.2 PCE-02 | MIL-STD-461F CE-102 | NO-A-STANAG-4370/AECTP-500-1:2021 NCE02 (kategoria 501)
9 Electrical, telecommunications and electronic products and equipment; military equipment. Emisja zaburzeń elektromagnetycznych promieniowanych w zakresie częstotli-wości od 10 kHz do 18 GHz, wytwarza-nych przez urządzenia oraz dołączone do tych urządzeń kable Direct measurement method NO-06-A500:2012 pkt. 3.14 PRE-02 | MIL-STD-461F RE-102 | NO-A-STANAG-4370/AECTP-500-1:2021 NRE02 (kategoria 501)
10 Electrical, telecommunications and electronic products and equipment; military equipment. Odporność na narażenia promieniowa-ne, pole elektryczne w zakresie często-tliwości 2 MHz do 18 GHz Direct measurement method NO-06-A500:2012 pkt. 3.17 PRS-02 | MIL-STD-461F RS-103 | NO-A-STANAG-4370/AECTP-500-1:2021 NRS02 (kategoria 501)
11 Electrical, telecommunications and electronic products and equipment; military equipment. Odporność na narażenia przewodzone, przewody elektryczne w zakresie 30 Hz do 150 kHz Direct measurement method NO-06-A500:2012 pkt. 3.4 PCS-01 | MIL-STD-461F CS-101 | NO-A-STANAG-4370/AECTP-500-1:2021 NCS01 (kategoria 501)
12 Electrical, telecommunications and electronic products and equipment; military equipment. Poziom zaburzeń promieniowanych wytwarzanych przez zespoły prądotwórcze w zakresie częstotliwości od 2 MHz do 18 GHz oraz zaburzeń przewodzonych w zakresie częstotliwo-ści od 10 kHz do 30 MHz wytwarzanych przez zespoły prądotwórcze NO-61-A208:2021 | NO-61-A208:2021/AC1:2021 p. 2.1.14, 3.14
13 Electrical, telecommunications and electronic products and equipment; military equipment. Emisja promieniowana; pomiar poziomu indukcji magnetycznej zaburzeń w zakresie częstotliwości od 30 Hz do 100 kHz. Direct measurement method NO-06-A500:2012 pkt. 3.13 PRE-01 | MlL-STD-461F/G RE-101 | NO-A-STANAG-4370/AECTP-500-1:2021 NRE01 (kategoria 501)
14 Electrical, telecommunications and electronic products and equipment; military equipment. Odporność na narażenia promieniowa-ne; pole magnetyczne, w zakresie czę-stotliwości od 30 Hz do100 kHz Direct measurement method NO-06-A500:2012 pkt. 3.16 PRS-01 | MIL-STD461F/G RS-101 | NO-A-STANAG-4370/AECTP-500-1:2021 NRS01 (kategoria 501)
15 Electrical, telecommunications and electronic products and equipment; military equipment. Emisje przewodzone; pomiar poziomu emisji zaburzeń elektromagnetycznych przewodzonych w zakresie częstotliwo-ści od 30 Hz do 10 kHz. Direct measurement method NO-06-A500:2012 pkt. 3.1 PCE-01 | MIL-STD-461F/G CE-101 | NO-A-STANAG-4370/AECTP-500-1:2021 NCE01 (kategoria 501)
16 Electrical, telecommunications and electronic products and equipment; military equipment. Odporność na narażenia przewodzone, prądy strukturalne w zakresie częstotli-wości od 50 Hz do 100 kHz. Direct measurement method NO-06-A500:2012 pkt. 3.8 PCS-05 | MIL-STD-461F/G CS-109 | NO-A-STANAG-4370/AECTP-500-1:2021 NCS06 (kategoria 501)
17 Electrical, telecommunications and electronic products and equipment; military equipment. Odporność na narażenia przewodzone, wprowadzane do kabli, 10kHz – 200MHz Direct measurement method NO-06-A500:2012 pkt. 3.9 PCS-06 | MIL-STD-461F/G CS-114 | NO-A-STANAG-4370/AECTP-500-1:2021 NCS07 (kategoria 501)
18 Electrical, telecommunications and electronic products and equipment; military equipment. Immunity to conducted disturbances, impulse excitation Direct measurement method NO-06-A500:2012 pkt. 3.10 PCS-07 | MIL-STD-461F/G CS-115 | NO-A-STANAG-4370/AECTP-500-1:2021 NCS08 (kategoria 501)
19 Electrical, telecommunications and electronic products and equipment; military equipment. Odporność na narażenia przewodzone, tłumiona fala sinusoidalna, przewody zasilania i sygnałowe, 10 kHz – 100 MHz Direct measurement method NO-06-A500:2012 pkt. 3.11 PCS-08 | MIL-STD-461F/G CS-116 | NO-A-STANAG-4370/AECTP-500-1:2021 NCS09 (kategoria 501)
20 Electrical, telecommunications and electronic products and equipment; military equipment. Electric field strength
w paśmie częstotliwości: 0,1 MHz – 3GHz Range (0,5 – 1000) V/m. w paśmie częstotliwości: 80 MHz – 60 GHz Range (0,7 – 300) V/m.
Direct measurement method. NO-06-A215-2:2022 p. 7.5 | PN-T-06580-3:2002 z wyłączeniem p. 2.1.4.2
21 Electrical, telecommunications and electronic products and equipment; military equipment. Magnetic field strength
w paśmie częstotliwości: (0,1 – 30 ) MHz Range (0,015 – 16) A/m w paśmie częstotliwości: (27 – 1000) MHz Range (0,01 – 12) A/m
Direct measurement method. NO-06-A215-2:2022 p. 7.5 | PN-T-06580-3:2002 z wyłączeniem p. 2.1.4.2
22 Electrical, telecommunications and electronic products and equipment; military equipment. Power density
w paśmie częstotliwości: (0,3 – 60) GHz Range (0,002– 238) W/m2. (calculated)
NO-06-A215-2:2022 p. 7.5 | PN-T-06580-3:2002 z wyłączeniem p. 2.1.4.2
23 Environment – electromagnetic field in the vicinity of radiocommunication installations: (broadband measurements) Electric field strength:
in the frequency range od 0,1 MHz do 3GHz Range (0,5 – 1000) V/m. in the frequency range od 80 MHz do 60 GHz Range (0,7 – 300) V/m.
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method. Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
24 Environment – electromagnetic field in the vicinity of radiocommunication installations: (broadband measurements) Magnetic field strength:
w zakresie częstotliwości: od 0,1 MHz do 30 MHz Range (0,015 – 16) A/m in the frequency range od 27 MHz do 1000 MHz Range (0,01 – 12) A/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method. Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
25 Environment – electromagnetic field in the vicinity of radiocommunication installations: (broadband measurements) Magnetic field strength:
in the frequency range od 0,3 GHz do 60 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) (Dz.U. 2022 poz. 2630)
26 Environment – electromagnetic field in the vicinity of radiocommunication installations: (broadband measurements) Power density:
in the frequency range od 0,3 GHz do 60 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) (Dz.U. 2022 poz. 2630)
27 Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) Electric field strength:
in the frequency range od 0,1 MHz do 3 GHz Range (0,5 – 1000) V/m. in the frequency range od 80 MHz do 60 GHz Range (0,7 – 300) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
28 Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) Magnetic field strength:
in the frequency range od 0,1 MHz do 30 MHz Range (0,015 – 16) A/m in the frequency range od 27 MHz do 1000 MHz Range (0,01 – 12) A/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method. Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
29 Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) Magnetic field strength:
in the frequency range od 0,3 GHz do 60 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
30 Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) Power density:
in the frequency range od 0,3 GHz do 60 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)

Reference standards (48)

ANSI/IEEE Std 149:1979 (R2008)
EN 61000-5-7:2001
MIL-STD-461F CE-102
MIL-STD-461F CS-101
MIL-STD-461F RE-102
MIL-STD-461F RS-103
MIL-STD-461F/G CE-101
MIL-STD-461F/G CS-109
MIL-STD-461F/G CS-114
MIL-STD-461F/G CS-115
MIL-STD-461F/G CS-116
MIL-STD461F/G RS-101
MlL-STD-461F/G RE-101
NO-06-A215-2:2022 p. 7.5
NO-06-A500:2012 pkt. 3.1 PCE-01
NO-06-A500:2012 pkt. 3.10 PCS-07
NO-06-A500:2012 pkt. 3.11 PCS-08
NO-06-A500:2012 pkt. 3.13 PRE-01
NO-06-A500:2012 pkt. 3.14 PRE-02
NO-06-A500:2012 pkt. 3.16 PRS-01
NO-06-A500:2012 pkt. 3.17 PRS-02
NO-06-A500:2012 pkt. 3.2 PCE-02
NO-06-A500:2012 pkt. 3.4 PCS-01
NO-06-A500:2012 pkt. 3.8 PCS-05
NO-06-A500:2012 pkt. 3.9 PCS-06
NO-06-A501:2009
NO-06-A501:2009/A1:2018
NO-61-A208:2021
NO-61-A208:2021/AC1:2021 p. 2.1.14, 3.14
NO-A-STANAG-4370/AECTP-500-1:2021 NCE01 (kategoria 501)
NO-A-STANAG-4370/AECTP-500-1:2021 NCE02 (kategoria 501)
NO-A-STANAG-4370/AECTP-500-1:2021 NCS01 (kategoria 501)
NO-A-STANAG-4370/AECTP-500-1:2021 NCS06 (kategoria 501)
NO-A-STANAG-4370/AECTP-500-1:2021 NCS07 (kategoria 501)
NO-A-STANAG-4370/AECTP-500-1:2021 NCS08 (kategoria 501)
NO-A-STANAG-4370/AECTP-500-1:2021 NCS09 (kategoria 501)
NO-A-STANAG-4370/AECTP-500-1:2021 NRE01 (kategoria 501)
NO-A-STANAG-4370/AECTP-500-1:2021 NRE02 (kategoria 501)
NO-A-STANAG-4370/AECTP-500-1:2021 NRS01 (kategoria 501)
NO-A-STANAG-4370/AECTP-500-1:2021 NRS02 (kategoria 501)
PB-05 wydanie D z dnia 17.04.2024 r.
PB-06 wydanie E z dnia 12.04.2022 r.
PN-EN 50147-1:2000
PN-EN 61000-5-7:2005
PN-T-06580-3:2002 z wyłączeniem p. 2.1.4.2
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) (Dz.U. 2022 poz. 2630)
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)