🇵🇱 PRZEDSIĘBIORSTWO HANDLOWO USŁUGOWE PL
EnvironmentConstructionMaterials & polymers
PRZEDSIĘBIORSTWO HANDLOWO USŁUGOWE is a laboratory accredited by PCA under number AB 1194 (Zławieś Wielka, Poland). Its accreditation scope covers 8 test methods in the following areas: Environment, Construction, Materials & polymers. Test objects include: Workplace environment - air, Workplace environment - indoor electric lighting, Workplace environment - noise. Most frequently used techniques: Direct measurement method, Gravimetric method, Personal dosimetry method.
At a glance
- Accreditation number: PCA AB 1194
- Methods in scope: 8
- Types of test objects: 3
- Techniques used: 3
- City: Zławieś Wielka, Poland
- Accreditation number
- AB 1194
- Accreditation body
- PCA
- Address
- „UNI-LAB” S.C., KRZYSZTOF FRANDZEL, KRZYSZTOF KALINOWSKI, Górsk, ul. Modrzewiowa 3, 87-134 Zławieś Wielka
- City
- Zławieś Wielka, Poland
What this laboratory tests (3)
- Workplace environment - air — 4 methods
- Workplace environment - indoor electric lighting — 2 methods
- Workplace environment - noise — 2 methods
Analytical techniques used (3)
- Direct measurement method — 2 methods
- Gravimetric method — 2 methods
- Personal dosimetry method — 1 method
Accreditation scope — test methods (8)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (40 – 135) dB C-weighted peak sound pressure level Range (40 – 138) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | |
| 2 | Workplace environment - noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | ||
| 3 | Workplace environment - indoor electric lighting | Illuminance Range (5 – 5 000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 4 | Workplace environment - indoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 5 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents – inhalable fraction – respirable fraction inorganic substances, including – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 6 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 7 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction Portland cement Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Coal (hard, brown) Range (0,1 – 17,0) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 8 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction Portland cement Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,1 – 6,31) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
Reference standards (8)
PN-83/E-04040.03
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08