PCA AB 1193 • Środa Wielkopolska, Poland • 27 methods

Water & wastewaterMicrobiology

MIEJSKIE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ is a laboratory accredited by PCA under number AB 1193 (Środa Wielkopolska, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, water, Wastewater, Water, water intended for human consumption, wastewater, Water, wastewater. Most frequently used techniques: Spectrophotometric method, MPN method, Colorimetric method.

At a glance

  • Accreditation number: PCA AB 1193
  • Methods in scope: 27
  • Types of test objects: 5
  • Techniques used: 13
  • City: Środa Wielkopolska, Poland
Accreditation number
AB 1193
Accreditation body
PCA
Address
WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w Środzie Wlkp., ul. Harcerska 16, 63-000 Środa Wielkopolska, LABORATORIUM, Chwałkowo 25
City
Środa Wielkopolska, Poland

What this laboratory tests (5)

Analytical techniques used (13)

Laboratory locations

Certificate information

Issue date
26.05.2026
Issue no.
15

Accreditation scope — test methods (27)

No. Test object Methodology / Parameters Technique Reference document
Laboratory; Chwałkowo 25, 63-000 Środa Wielkopolska
1 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6
2 Water intended for human consumption, water Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 10.3; 10.4;11
3 Water intended for human consumption, water Turbidity
Range (0,50 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4
4 Water intended for human consumption, water Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 metoda D
5 Water intended for human consumption, water Electrical conductivity
Range (5 – 3000) μS/cm
Conductometric method PN-EN 27888:1999
6 Water intended for human consumption, water Free chlorine
Range (0,05 – 1,50) mg/l
Colorimetric method PB/04 wyd. 1 z dn. 02.01.2012 r.
7 Water intended for human consumption, water Manganese concentration
Range (0,030 – 1,00) mg/l
Spectrophotometric method Metoda Hach Lange LCW 032 wydanie z 11.2019 r.
8 Water intended for human consumption, water Total content of calcium and magnesium (total hardness)
Range (10 - 600) mg/l CaCO3
Titrimetric method PN-ISO 6059-1999
9 Water intended for human consumption, water Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
10 Water intended for human consumption, water Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
11 Water intended for human consumption, water Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
12 Water intended for human consumption, water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
13 Water, wastewater Total phosphorus concentration
Range (0,050 – 2,00) mg/l Phosphate concentration Range (0,150 – 5,00) mg/l
Spectrophotometric method PB/02 wydanie 1 z dnia 01.12.2017 | na podstawie metody Hach Lange LCK 349
14 Water, wastewater Ammonium ion concentration
Range (2,50 – 60,0) mg/l Ammonium nitrogen concentration Range (2,00 – 47,0) mg/l
Spectrophotometric method Metoda Hach Lange LCK 303 wydanie z 10.2019 r.
15 Water, wastewater Iron concentration
Range (0,200 – 6,00) mg/l
Spectrophotometric method Metoda Hach Lange LCK 321 wydanie z 07.2019 r.
16 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
17 Wastewater Chemical oxygen demand - COD-Cr
Range (15,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
18 Wastewater Biochemical oxygen demand
BOD5 Range (1 – 6 000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
19 Wastewater Total suspended solids (TSS)
Range (3,0 – 3000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
20 Wastewater Total nitrogen concentration
Range (1,00 – 500) mg/l
Spectrophotometric method PB/06 wydanie 2 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 138 i LCK 338
21 Wastewater Ammonium nitrogen concentration
Range (47,0 – 130) mg/l
Spectrophotometric method Metoda Hach Lange LCK 302 wydanie z 10.2019 r.
22 Wastewater Total phosphorus concentration
Range (2,00 – 60,0) mg/l
Spectrophotometric method PB/01 wydanie 01 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 350
23 Water, water intended for human consumption, wastewater Ammonium ion concentration
Range (0,050 – 2,50) mg/l Ammonium nitrogen concentration Range (0,039 – 2,00) mg/l
Spectrophotometric method Metoda Hach Lange LCK 304 wydanie z 10.2019 r.
24 Water, water intended for human consumption, wastewater Nitrate concentration
Range (1,00 – 60,0) mg/l Nitrate nitrogen concentration Range (0,230 – 13,5) mg/l
Spectrophotometric method Metoda Hach Lange LCK 339 wydanie z 10.2019 r.
25 Water, water intended for human consumption, wastewater Nitrite concentration
Range (0,050 – 2,00) mg/l Nitrite nitrogen concentration Range (0,015 – 0,600) mg/l
Spectrophotometric method Metoda Hach Lange LCK 341 wydanie z 10.2019 r.
26 Water, water intended for human consumption, wastewater Iron concentration
Range (0,100 – 1,00) mg/l
Spectrophotometric method Metoda Hach Lange LCK 521 wydanie z 06.2019 r.
27 Water, water intended for human consumption, wastewater pH
Range 4,0 –10,0
Potentiometric method PN-EN ISO 10523:2012

Reference standards (27)

Metoda Hach Lange LCK 302 wydanie z 10.2019 r.
Metoda Hach Lange LCK 303 wydanie z 10.2019 r.
Metoda Hach Lange LCK 304 wydanie z 10.2019 r.
Metoda Hach Lange LCK 321 wydanie z 07.2019 r.
Metoda Hach Lange LCK 339 wydanie z 10.2019 r.
Metoda Hach Lange LCK 341 wydanie z 10.2019 r.
Metoda Hach Lange LCK 521 wydanie z 06.2019 r.
Metoda Hach Lange LCW 032 wydanie z 11.2019 r.
PB/01 wydanie 01 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 350
PB/02 wydanie 1 z dnia 01.12.2017
PB/04 wyd. 1 z dn. 02.01.2012 r.
PB/06 wydanie 2 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 138 i LCK 338
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4
PN-EN ISO 7887:2012 metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 10.3; 10.4;11
PN-ISO 6059-1999
na podstawie metody Hach Lange LCK 349

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201193