🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ PL
Water & wastewaterMicrobiology
MIEJSKIE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ is a laboratory accredited by PCA under number AB 1193 (Środa Wielkopolska, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, water, Wastewater, Water, water intended for human consumption, wastewater, Water, wastewater. Most frequently used techniques: Spectrophotometric method, MPN method, Colorimetric method.
At a glance
- Accreditation number: PCA AB 1193
- Methods in scope: 27
- Types of test objects: 5
- Techniques used: 13
- City: Środa Wielkopolska, Poland
- Accreditation number
- AB 1193
- Accreditation body
- PCA
- Address
- WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w Środzie Wlkp., ul. Harcerska 16, 63-000 Środa Wielkopolska, LABORATORIUM, Chwałkowo 25
- City
- Środa Wielkopolska, Poland
What this laboratory tests (5)
- Water intended for human consumption, water — 11 methods
- Wastewater — 7 methods
- Water, water intended for human consumption, wastewater — 5 methods
- Water, wastewater — 3 methods
- Water intended for human consumption — 1 method
Analytical techniques used (13)
- Spectrophotometric method — 12 methods
- MPN method — 2 methods
- Colorimetric method — 1 method
- Conductometric method — 1 method
- Electrochemical method — 1 method
- Gravimetric method — 1 method
- Manual method; Automatic method — 1 method
- Membrane filtration method — 1 method
- Nephelometric method — 1 method
- Plate method (pour plate) — 1 method
- Potentiometric method — 1 method
- Titrimetric method — 1 method
- Visual method — 1 method
Laboratory locations
- Laboratorium; Chwałkowo 25, 63-000 Środa Wielkopolska —
Accreditation scope — test methods (27)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory; Chwałkowo 25, 63-000 Środa Wielkopolska | |||||
| 1 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6 | ||
| 2 | Water intended for human consumption, water | Sampling for chemical and physical testing | P N - I S O 5667-5:2017-10 z wyłączeniem pkt. 10.3; 10.4;11 | ||
| 3 | Water intended for human consumption, water | Turbidity Range (0,50 – 40) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4 | |
| 4 | Water intended for human consumption, water | Colour Range (5 – 70) mg/l Pt |
Visual method | PN-EN ISO 7887:2012 metoda D | |
| 5 | Water intended for human consumption, water | Electrical conductivity Range (5 – 3000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 6 | Water intended for human consumption, water | Free chlorine Range (0,05 – 1,50) mg/l |
Colorimetric method | PB/04 wyd. 1 z dn. 02.01.2012 r. | |
| 7 | Water intended for human consumption, water | Manganese concentration Range (0,030 – 1,00) mg/l |
Spectrophotometric method | Metoda Hach Lange LCW 032 wydanie z 11.2019 r. | |
| 8 | Water intended for human consumption, water | Total content of calcium and magnesium (total hardness) Range (10 - 600) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059-1999 | |
| 9 | Water intended for human consumption, water | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 10 | Water intended for human consumption, water | Most probable number, Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 11 | Water intended for human consumption, water | Total viable count at 22 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 12 | Water intended for human consumption, water | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 13 | Water, wastewater | Total phosphorus concentration Range (0,050 – 2,00) mg/l Phosphate concentration Range (0,150 – 5,00) mg/l |
Spectrophotometric method | PB/02 wydanie 1 z dnia 01.12.2017 | na podstawie metody Hach Lange LCK 349 | |
| 14 | Water, wastewater | Ammonium ion concentration Range (2,50 – 60,0) mg/l Ammonium nitrogen concentration Range (2,00 – 47,0) mg/l |
Spectrophotometric method | Metoda Hach Lange LCK 303 wydanie z 10.2019 r. | |
| 15 | Water, wastewater | Iron concentration Range (0,200 – 6,00) mg/l |
Spectrophotometric method | Metoda Hach Lange LCK 321 wydanie z 07.2019 r. | |
| 16 | Wastewater | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 17 | Wastewater | Chemical oxygen demand - COD-Cr Range (15,0 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 18 | Wastewater | Biochemical oxygen demand BOD5 Range (1 – 6 000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 19 | Wastewater | Total suspended solids (TSS) Range (3,0 – 3000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 20 | Wastewater | Total nitrogen concentration Range (1,00 – 500) mg/l |
Spectrophotometric method | PB/06 wydanie 2 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 138 i LCK 338 | |
| 21 | Wastewater | Ammonium nitrogen concentration Range (47,0 – 130) mg/l |
Spectrophotometric method | Metoda Hach Lange LCK 302 wydanie z 10.2019 r. | |
| 22 | Wastewater | Total phosphorus concentration Range (2,00 – 60,0) mg/l |
Spectrophotometric method | PB/01 wydanie 01 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 350 | |
| 23 | Water, water intended for human consumption, wastewater | Ammonium ion concentration Range (0,050 – 2,50) mg/l Ammonium nitrogen concentration Range (0,039 – 2,00) mg/l |
Spectrophotometric method | Metoda Hach Lange LCK 304 wydanie z 10.2019 r. | |
| 24 | Water, water intended for human consumption, wastewater | Nitrate concentration Range (1,00 – 60,0) mg/l Nitrate nitrogen concentration Range (0,230 – 13,5) mg/l |
Spectrophotometric method | Metoda Hach Lange LCK 339 wydanie z 10.2019 r. | |
| 25 | Water, water intended for human consumption, wastewater | Nitrite concentration Range (0,050 – 2,00) mg/l Nitrite nitrogen concentration Range (0,015 – 0,600) mg/l |
Spectrophotometric method | Metoda Hach Lange LCK 341 wydanie z 10.2019 r. | |
| 26 | Water, water intended for human consumption, wastewater | Iron concentration Range (0,100 – 1,00) mg/l |
Spectrophotometric method | Metoda Hach Lange LCK 521 wydanie z 06.2019 r. | |
| 27 | Water, water intended for human consumption, wastewater | pH Range 4,0 –10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
Reference standards (27)
Metoda Hach Lange LCK 302 wydanie z 10.2019 r.
Metoda Hach Lange LCK 303 wydanie z 10.2019 r.
Metoda Hach Lange LCK 304 wydanie z 10.2019 r.
Metoda Hach Lange LCK 321 wydanie z 07.2019 r.
Metoda Hach Lange LCK 339 wydanie z 10.2019 r.
Metoda Hach Lange LCK 341 wydanie z 10.2019 r.
Metoda Hach Lange LCK 521 wydanie z 06.2019 r.
Metoda Hach Lange LCW 032 wydanie z 11.2019 r.
P N - I S O 5667-5:2017-10 z wyłączeniem pkt. 10.3; 10.4;11
PB/01 wydanie 01 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 350
PB/02 wydanie 1 z dnia 01.12.2017
PB/04 wyd. 1 z dn. 02.01.2012 r.
PB/06 wydanie 2 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 138 i LCK 338
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4
PN-EN ISO 7887:2012 metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 6059-1999
na podstawie metody Hach Lange LCK 349