🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ PL

PCA AB 1193 • Środa Wielkopolska, Poland • 27 methods

Water & wastewaterMicrobiology

MIEJSKIE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ is a laboratory accredited by PCA under number AB 1193 (Środa Wielkopolska, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, water, Wastewater, Water, water intended for human consumption, wastewater, Water, wastewater. Most frequently used techniques: Spectrophotometric method, MPN method, Colorimetric method.

At a glance

  • Accreditation number: PCA AB 1193
  • Methods in scope: 27
  • Types of test objects: 5
  • Techniques used: 13
  • City: Środa Wielkopolska, Poland
Accreditation number
AB 1193
Accreditation body
PCA
Address
WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w Środzie Wlkp., ul. Harcerska 16, 63-000 Środa Wielkopolska, LABORATORIUM, Chwałkowo 25
City
Środa Wielkopolska, Poland

What this laboratory tests (5)

Analytical techniques used (13)

Laboratory locations

Accreditation scope — test methods (27)

No. Test object Methodology / Parameters Technique Reference document
Laboratory; Chwałkowo 25, 63-000 Środa Wielkopolska
1 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6
2 Water intended for human consumption, water Sampling for chemical and physical testing P N - I S O 5667-5:2017-10 z wyłączeniem pkt. 10.3; 10.4;11
3 Water intended for human consumption, water Turbidity
Range (0,50 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4
4 Water intended for human consumption, water Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 metoda D
5 Water intended for human consumption, water Electrical conductivity
Range (5 – 3000) μS/cm
Conductometric method PN-EN 27888:1999
6 Water intended for human consumption, water Free chlorine
Range (0,05 – 1,50) mg/l
Colorimetric method PB/04 wyd. 1 z dn. 02.01.2012 r.
7 Water intended for human consumption, water Manganese concentration
Range (0,030 – 1,00) mg/l
Spectrophotometric method Metoda Hach Lange LCW 032 wydanie z 11.2019 r.
8 Water intended for human consumption, water Total content of calcium and magnesium (total hardness)
Range (10 - 600) mg/l CaCO3
Titrimetric method PN-ISO 6059-1999
9 Water intended for human consumption, water Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
10 Water intended for human consumption, water Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
11 Water intended for human consumption, water Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
12 Water intended for human consumption, water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
13 Water, wastewater Total phosphorus concentration
Range (0,050 – 2,00) mg/l Phosphate concentration Range (0,150 – 5,00) mg/l
Spectrophotometric method PB/02 wydanie 1 z dnia 01.12.2017 | na podstawie metody Hach Lange LCK 349
14 Water, wastewater Ammonium ion concentration
Range (2,50 – 60,0) mg/l Ammonium nitrogen concentration Range (2,00 – 47,0) mg/l
Spectrophotometric method Metoda Hach Lange LCK 303 wydanie z 10.2019 r.
15 Water, wastewater Iron concentration
Range (0,200 – 6,00) mg/l
Spectrophotometric method Metoda Hach Lange LCK 321 wydanie z 07.2019 r.
16 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
17 Wastewater Chemical oxygen demand - COD-Cr
Range (15,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
18 Wastewater Biochemical oxygen demand
BOD5 Range (1 – 6 000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
19 Wastewater Total suspended solids (TSS)
Range (3,0 – 3000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
20 Wastewater Total nitrogen concentration
Range (1,00 – 500) mg/l
Spectrophotometric method PB/06 wydanie 2 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 138 i LCK 338
21 Wastewater Ammonium nitrogen concentration
Range (47,0 – 130) mg/l
Spectrophotometric method Metoda Hach Lange LCK 302 wydanie z 10.2019 r.
22 Wastewater Total phosphorus concentration
Range (2,00 – 60,0) mg/l
Spectrophotometric method PB/01 wydanie 01 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 350
23 Water, water intended for human consumption, wastewater Ammonium ion concentration
Range (0,050 – 2,50) mg/l Ammonium nitrogen concentration Range (0,039 – 2,00) mg/l
Spectrophotometric method Metoda Hach Lange LCK 304 wydanie z 10.2019 r.
24 Water, water intended for human consumption, wastewater Nitrate concentration
Range (1,00 – 60,0) mg/l Nitrate nitrogen concentration Range (0,230 – 13,5) mg/l
Spectrophotometric method Metoda Hach Lange LCK 339 wydanie z 10.2019 r.
25 Water, water intended for human consumption, wastewater Nitrite concentration
Range (0,050 – 2,00) mg/l Nitrite nitrogen concentration Range (0,015 – 0,600) mg/l
Spectrophotometric method Metoda Hach Lange LCK 341 wydanie z 10.2019 r.
26 Water, water intended for human consumption, wastewater Iron concentration
Range (0,100 – 1,00) mg/l
Spectrophotometric method Metoda Hach Lange LCK 521 wydanie z 06.2019 r.
27 Water, water intended for human consumption, wastewater pH
Range 4,0 –10,0
Potentiometric method PN-EN ISO 10523:2012

Reference standards (27)

Metoda Hach Lange LCK 302 wydanie z 10.2019 r.
Metoda Hach Lange LCK 303 wydanie z 10.2019 r.
Metoda Hach Lange LCK 304 wydanie z 10.2019 r.
Metoda Hach Lange LCK 321 wydanie z 07.2019 r.
Metoda Hach Lange LCK 339 wydanie z 10.2019 r.
Metoda Hach Lange LCK 341 wydanie z 10.2019 r.
Metoda Hach Lange LCK 521 wydanie z 06.2019 r.
Metoda Hach Lange LCW 032 wydanie z 11.2019 r.
P N - I S O 5667-5:2017-10 z wyłączeniem pkt. 10.3; 10.4;11
PB/01 wydanie 01 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 350
PB/02 wydanie 1 z dnia 01.12.2017
PB/04 wyd. 1 z dn. 02.01.2012 r.
PB/06 wydanie 2 z dnia 01.12.2017 r. na podstawie metody Hach Lange LCK 138 i LCK 338
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4
PN-EN ISO 7887:2012 metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 6059-1999
na podstawie metody Hach Lange LCK 349