🇵🇱 MIEJSKIE WODOCIĄGI I KANALIZACJA Sp. z o.o. PL

PCA AB 1190 • Ostrowiec Świętokrzyski, Poland • 33 methods

Water & wastewaterMicrobiology

MIEJSKIE WODOCIĄGI I KANALIZACJA Sp. z o.o. is a laboratory accredited by PCA under number AB 1190 (Ostrowiec Świętokrzyski, Poland). Its accreditation scope covers 33 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water Water intended for human consumption, Wastewater Water, Wastewater, Water.

At a glance

  • Accreditation number: PCA AB 1190
  • Methods in scope: 33
  • Types of test objects: 5
  • City: Ostrowiec Świętokrzyski, Poland
Accreditation number
AB 1190
Accreditation body
PCA
Address
LABORATORIUM, ul. Sienkiewicza 91, 27-400 Ostrowiec Świętokrzyski
City
Ostrowiec Świętokrzyski, Poland

What this laboratory tests (5)

Accreditation scope — test methods (33)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing Temperature of the collected water sample Range: (2,0 – 50,0) °C PN-ISO 5667-5:2017-10 PN-77/C-04584
2 Water Water intended for human consumption pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
3 Water Water intended for human consumption Turbidity Range: (0,08 – 10) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
4 Water Water intended for human consumption Electrical conductivity Range: (10 – 1413) µS/cm Conductometric method PN-EN 27888:1999
5 Water Water intended for human consumption Nitrate concentration Range: (0,88 – 4,43) mg/l Spectrophotometric method PN-82/C-04576/08
6 Water Water intended for human consumption Nitrite concentration Range: (0,060 – 0,41) mg/l Spectrophotometric method PN-EN 26777:1999
7 Water Water intended for human consumption Total iron concentration Range: (50 – 1000 ) µg/l Spectrophotometric method PN-ISO 6332:2001
8 Water Water intended for human consumption Total manganese concentration Range: (50 – 1000 ) µg/l Spectrophotometric method PN-92/C-04590/03
9 Water Water intended for human consumption Ammonium nitrogen concentration Range: (0,10 – 1,4) mg/l Spectrophotometric method PN-C-04576-4:1994
10 Water Water intended for human consumption Colour Range: (4 – 50) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
11 Water Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3
12 Water Water intended for human consumption Total count of microorganisms at a temperature of 22 ⁰C Plate method (pour plate) PN-EN ISO 6222:2004
13 Water Water intended for human consumption Total count of microorganisms at a temperature of 36 ⁰C Plate method (pour plate)
14 Water Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
15 Water Water intended for human consumption Escherichia coli count Membrane filtration method
16 Water Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
17 Water Sampling for chemical and physical testing Temperature of the water sample taken Range: (2,0 – 50,0) ⁰C PN-EN ISO 5667-6: 2016-12 PN-77/C-04584
18 Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of the wastewater sample taken Range: (2,0 – 50,0) ⁰C PN-ISO 5667-10:2021-11 PN-77/C-04584
19 Wastewater Water pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
20 Wastewater Water Nitrate nitrogen concentration Range: (0,10 – 20,0) mg/l Spectrophotometric method PN-82/C-04576/08
21 Wastewater Water Total suspended solids (TSS) Range: (2,0 – 1000) mg/l Gravimetric method PN-EN 872:2007 + Ap1:2007
22 Wastewater Water Chloride concentration Range (5,0 – 400) mg/l Titrimetric method PN-ISO 9297:1994
23 Wastewater Water Nitrite nitrogen concentration Range: (0,013 – 5,00) mg/l Spectrophotometric method PN-EN 26777:1999
24 Wastewater Water Kjeldahl nitrogen concentration Range: (2,0 – 500) mg/l Titrimetric method PN-EN 25663:2001
25 Wastewater Water Total nitrogen concentration (calculated) PB-07 wyd.1 z dnia 30.10.2008 r.
26 Wastewater Water Total phosphorus concentration Range: (0,040 – 16,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
27 Wastewater Water Biochemical oxygen demand - BOD5 Range: (1,0 – 6,0) mg/l O2 Electrochemical method PN-EN 1899-2:2002
28 Wastewater Water Biochemical oxygen demand - BOD5 Range: (1,0 – 2000) mg/l O2 Electrochemical method PN-EN ISO 5815-1:2019-12
29 Wastewater Water Chemical oxygen demand - SP - COD Range (10,0 – 6000) mg/l O2 Spectrophotometric method PN-ISO 15705:2005
30 Wastewater Chemical oxygen demand - COD - Cr Range (20,0 – 6000) mg/l O2 Titrimetric method PN-ISO 6060:2006
31 Wastewater Ammonium nitrogen concentration Range: (0,20 – 2,0) mg/l Spectrophotometric method PN-C-04576-4:1994
32 Wastewater Ammonium nitrogen concentration Range: (1,0 – 500) mg/l Titrimetric method PN-ISO 5664:2002
33 Wastewater Sulfate concentration Range: (10 – 500) mg/l Gravimetric method PN-ISO 9280:2002

Reference standards (27)

PB-07 wyd.1 z dnia 30.10.2008 r.
PN-82/C-04576/08
PN-92/C-04590/03
PN-C-04576-4:1994
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3
PN-EN ISO 5667-6: 2016-12 PN-77/C-04584
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10 PN-77/C-04584
PN-ISO 6060:2006
PN-ISO 6332:2001
PN-ISO 9280:2002
PN-ISO 9297:1994