🇵🇱 MIEJSKIE WODOCIĄGI I KANALIZACJA Sp. z o.o. PL
Water & wastewaterMicrobiology
MIEJSKIE WODOCIĄGI I KANALIZACJA Sp. z o.o. is a laboratory accredited by PCA under number AB 1190 (Ostrowiec Świętokrzyski, Poland). Its accreditation scope covers 33 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water Water intended for human consumption, Wastewater Water, Wastewater, Water.
At a glance
- Accreditation number: PCA AB 1190
- Methods in scope: 33
- Types of test objects: 5
- City: Ostrowiec Świętokrzyski, Poland
- Accreditation number
- AB 1190
- Accreditation body
- PCA
- Address
- LABORATORIUM, ul. Sienkiewicza 91, 27-400 Ostrowiec Świętokrzyski
- City
- Ostrowiec Świętokrzyski, Poland
What this laboratory tests (5)
- Water Water intended for human consumption — 15 methods
- Wastewater Water — 11 methods
- Wastewater — 5 methods
- Water — 1 method
- Water intended for human consumption — 1 method
Accreditation scope — test methods (33)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of the collected water sample Range: (2,0 – 50,0) °C | PN-ISO 5667-5:2017-10 PN-77/C-04584 | ||
| 2 | Water Water intended for human consumption | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 3 | Water Water intended for human consumption | Turbidity Range: (0,08 – 10) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 4 | Water Water intended for human consumption | Electrical conductivity Range: (10 – 1413) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 5 | Water Water intended for human consumption | Nitrate concentration Range: (0,88 – 4,43) mg/l Spectrophotometric method | PN-82/C-04576/08 | ||
| 6 | Water Water intended for human consumption | Nitrite concentration Range: (0,060 – 0,41) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 7 | Water Water intended for human consumption | Total iron concentration Range: (50 – 1000 ) µg/l Spectrophotometric method | PN-ISO 6332:2001 | ||
| 8 | Water Water intended for human consumption | Total manganese concentration Range: (50 – 1000 ) µg/l Spectrophotometric method | PN-92/C-04590/03 | ||
| 9 | Water Water intended for human consumption | Ammonium nitrogen concentration Range: (0,10 – 1,4) mg/l Spectrophotometric method | PN-C-04576-4:1994 | ||
| 10 | Water Water intended for human consumption | Colour Range: (4 – 50) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 | ||
| 11 | Water Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3 | ||
| 12 | Water Water intended for human consumption | Total count of microorganisms at a temperature of 22 ⁰C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 13 | Water Water intended for human consumption | Total count of microorganisms at a temperature of 36 ⁰C Plate method (pour plate) | |||
| 14 | Water Water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 15 | Water Water intended for human consumption | Escherichia coli count Membrane filtration method | |||
| 16 | Water Water intended for human consumption | Intestinal enterococci count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 17 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range: (2,0 – 50,0) ⁰C | PN-EN ISO 5667-6: 2016-12 PN-77/C-04584 | ||
| 18 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method Temperature of the wastewater sample taken Range: (2,0 – 50,0) ⁰C | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 19 | Wastewater Water | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 20 | Wastewater Water | Nitrate nitrogen concentration Range: (0,10 – 20,0) mg/l Spectrophotometric method | PN-82/C-04576/08 | ||
| 21 | Wastewater Water | Total suspended solids (TSS) Range: (2,0 – 1000) mg/l Gravimetric method | PN-EN 872:2007 + Ap1:2007 | ||
| 22 | Wastewater Water | Chloride concentration Range (5,0 – 400) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 23 | Wastewater Water | Nitrite nitrogen concentration Range: (0,013 – 5,00) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 24 | Wastewater Water | Kjeldahl nitrogen concentration Range: (2,0 – 500) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 25 | Wastewater Water | Total nitrogen concentration (calculated) | PB-07 wyd.1 z dnia 30.10.2008 r. | ||
| 26 | Wastewater Water | Total phosphorus concentration Range: (0,040 – 16,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | ||
| 27 | Wastewater Water | Biochemical oxygen demand - BOD5 Range: (1,0 – 6,0) mg/l O2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 28 | Wastewater Water | Biochemical oxygen demand - BOD5 Range: (1,0 – 2000) mg/l O2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 29 | Wastewater Water | Chemical oxygen demand - SP - COD Range (10,0 – 6000) mg/l O2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 30 | Wastewater | Chemical oxygen demand - COD - Cr Range (20,0 – 6000) mg/l O2 Titrimetric method | PN-ISO 6060:2006 | ||
| 31 | Wastewater | Ammonium nitrogen concentration Range: (0,20 – 2,0) mg/l Spectrophotometric method | PN-C-04576-4:1994 | ||
| 32 | Wastewater | Ammonium nitrogen concentration Range: (1,0 – 500) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 33 | Wastewater | Sulfate concentration Range: (10 – 500) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
Reference standards (27)
PB-07 wyd.1 z dnia 30.10.2008 r.
PN-82/C-04576/08
PN-92/C-04590/03
PN-C-04576-4:1994
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3
PN-EN ISO 5667-6: 2016-12 PN-77/C-04584
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10 PN-77/C-04584
PN-ISO 6060:2006
PN-ISO 6332:2001
PN-ISO 9280:2002
PN-ISO 9297:1994