🇵🇱 PRZEDSIĘBIORSTWO HANDLOWO-USŁUGOWE PL

PCA AB 1178 • Swarzędz, Poland • 22 methods

EnvironmentConstruction

PRZEDSIĘBIORSTWO HANDLOWO-USŁUGOWE is a laboratory accredited by PCA under number AB 1178 (Swarzędz, Poland). Its accreditation scope covers 22 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment − air, Workplace environment − outdoor electric lighting, Workplace environment – hand-arm vibration, Workplace environment − cold microclimate. Most frequently used techniques: Direct measurement method, Gravimetric method, Electrochemical method.

At a glance

  • Accreditation number: PCA AB 1178
  • Methods in scope: 22
  • Types of test objects: 9
  • Techniques used: 4
  • City: Swarzędz, Poland
Accreditation number
AB 1178
Accreditation body
PCA
Address
OŚRODEK BADAŃ I OCENY ŚRODOWISKA PRACY, „TOX-LUX” s.c. Maciej Łabęda, Katarzyna Malinowska, ul. Łąkowa 31a, 62-007 Biskupice, LABORATORIUM BADAWCZE, ul. Staszica 51, 62-020 Swarzędz
City
Swarzędz, Poland

What this laboratory tests (9)

Analytical techniques used (4)

Laboratory locations

Accreditation scope — test methods (22)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment − air Sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction metals and their compounds, including – inhalable fraction – respirable fraction asbestos respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres man-made mineral fibres, excluding refractory ceramic fibres respirable fibres silicon carbide fibrous respirable fibres
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
2 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
3 Workplace environment − air Concentration of harmful dust agents – inhalable fraction
Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous man-made mineral fibres, excluding refractory ceramic fibres silicon carbide fibrous Range (0,12 – 16,60) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/ Ap1:2022-08
4 Workplace environment − air Concentration of harmful dust agents – respirable fraction
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,11 – 15,15) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/ Ap1:2022-08
5 Workplace environment − air Gas concentrations
CO (2,3-232) mg/m3 Range (2-200) ppm
Electrochemical method PB-04 Wydanie 2 z dnia 03.01.2025 r.
6 Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (35 − 137) dB C-weighted peak sound pressure level Range (35 – 137) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11
7 Workplace environment − noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11
8 Workplace environment − indoor electric lighting Illuminance
Range (5 – 9 000) lx
Direct measurement method PN-83/E-04040.03
9 Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
10 Workplace environment − outdoor electric lighting Illuminance
Range (0,5 – 5 000) lx
Direct measurement method PN-83/E-04040.03
11 Workplace environment − outdoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
12 Workplace environment − outdoor electric lighting Ratio of minimum to maximum illuminance (calculated) PN-83/E-04040.03
13 Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,5 – 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
14 Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
15 Workplace environment– whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,03 – 35,0) m/s2
Direct measurement method PN-EN 14253+A1:2011
16 Workplace environment– whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
17 Workplace environment − moderate microclimate Air temperature
Range (10,0 – 40,0) 0C Black globe temperature Range (10,0 – 40,0) 0C Air humidity Range (20,0 – 90,0) % Air velocity Range (0,15 – 4,70) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
18 Workplace environment − moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
19 Workplace environment − hot microclimate Air temperature
Range (15,0 – 40,0) 0C Natural wet bulb temperature Range (15,0 – 40,0) 0C Black globe temperature Range (15,0 – 40,0) 0C
Direct measurement method PN-EN ISO 7243:2018-01
20 Workplace environment − hot microclimate WBGTeff index (calculated) PN-EN ISO 7243:2018-01
21 Workplace environment − cold microclimate Air temperature
Range (-20,0 – 10,0) 0C Black globe temperature Range (-20,0 – 10,0) 0C Air humidity Range (20,0 – 90,0) % Air velocity Range (0,15 – 4,70) m/s
Direct measurement method PN-EN ISO 11079:2008
22 Workplace environment − cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008

Reference standards (17)

PB-04 Wydanie 2 z dnia 03.01.2025 r.
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/ Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/ Ap1:2022-08