🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI PL
Water & wastewaterEnvironmentMicrobiology
MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 1177 (Puławy, Poland). Its accreditation scope covers 31 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Water intended for human consumption, Wastewater, Osady ściekowe, OdpadyO): kod 19 08 05, Water, Water intended for human consumption, Wastewater. Most frequently used techniques: Spectrophotometric method, Electrochemical method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 1177
- Methods in scope: 31
- Types of test objects: 4
- Techniques used: 11
- City: Puławy, Poland
- Accreditation number
- AB 1177
- Accreditation body
- PCA
- Address
- „WODOCIĄGI PUŁAWSKIE” Sp. z o.o., ul. Skowieszyńska 51, 24-100 Puławy, WYDZIAŁ LABORATORIUM, ul. Komunalna 7
- City
- Puławy, Poland
What this laboratory tests (4)
- Water intended for human consumption — 13 methods
- Wastewater — 10 methods
- Osady ściekowe, OdpadyO): kod 19 08 05 — 4 methods
- Water, Water intended for human consumption, Wastewater — 4 methods
Analytical techniques used (11)
- Spectrophotometric method — 7 methods
- Electrochemical method — 3 methods
- Gravimetric method — 3 methods
- Membrane filtration method — 3 methods
- Plate method (pour plate) — 2 methods
- Potentiometric method — 2 methods
- Conductometric method — 1 method
- Manual and automatic method — 1 method
- Nephelometric method — 1 method
- Titrimetric method — 1 method
- Visual method — 1 method
Laboratory locations
- Wydział Laboratorium — ul. Komunalna 7
Accreditation scope — test methods (31)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Wydział Laboratorium | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 2 | Water intended for human consumption | Temperatura wody/ próbki pobranej wody Range (4,0 – 50,0) ºC |
Procedura badawcza PB-01 wyd. V z dn. 02.01.2020 r. | ||
| 3 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 4 | Water intended for human consumption | Total iron concentration Range (10 – 50000) µg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 5 | Water intended for human consumption | Colour Range (1 – 40) mg/l Pt |
Visual method | PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda D | |
| 6 | Water intended for human consumption | Turbidity Range (0,2 – 20) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 7 | Water intended for human consumption | Electrical conductivity Range (10 – 2500) µS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 8 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 9 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 10 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 11 | Water intended for human consumption | Ogólna liczba mikroorganizmów w 22 ºC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 12 | Water intended for human consumption | Ogólna liczba mikroorganizmów w 36 ºC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 13 | Water intended for human consumption | Manganese concentration Range (5 – 5000) µg/l |
Spectrophotometric method | Procedura badawcza PB-04 wyd. IV z dn. 02.01.2020 r. | na podstawie testu HACH LCW 032 i LCW 532 | |
| 14 | Water, Water intended for human consumption, Wastewater | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 15 | Water, Water intended for human consumption, Wastewater | Ammonium nitrogen concentration Range (0,05 – 100) mg/l Ammonium ion concentration (0,06 – 129) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 16 | Water, Water intended for human consumption, Wastewater | Nitrite nitrogen concentration Range (0,003 – 65) mg/l Nitrite concentration (0,010 – 213) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 17 | Water, Water intended for human consumption, Wastewater | Nitrate nitrogen concentration Range (0,46 – 440) mg/l Nitrate concentration (2,00 – 1950) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 18 | Wastewater | Chemical oxygen demand - COD-Cr Range (15 – 10000) mg/l O2 |
Spectrophotometric method | PN-EN ISO 15705:2005 | |
| 19 | Wastewater | Biochemical oxygen demand - BOD5 Range (3 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 20 | Wastewater | Biochemical oxygen demand - BOD5 Range (0,5 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 21 | Wastewater | Dissolved oxygen concentration Range (1,0 – 10) mg/l O2 |
Electrochemical method | PN-EN ISO 5814:2013-04 | |
| 22 | Wastewater | Kjeldahl nitrogen concentration Range (1,0 – 200) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 23 | Wastewater | Total nitrogen concentration (calculated) | Procedura badawcza PB-03 wyd. III z dn. 02.01.2020 r. | ||
| 24 | Wastewater | Total phosphorus concentration Range (0,05 – 40) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010 | |
| 25 | Wastewater | Total suspended solids (TSS) Range (5,0 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 26 | Wastewater | Sampling for chemical and physical testing | Manual and automatic method | PN-ISO 5667-10:2021-11 | |
| 27 | Wastewater | Temperature of wastewater/ collected wastewater sample Range (4,0 – 50,0) ºC |
Procedura badawcza PB-01 wyd. V z dn. 02.01.2020 r. | ||
| 28 | Osady ściekowe, OdpadyO): kod 19 08 05 | Dry residue, water content Range (0,1 – 99,9) % Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN 12880:2004 | |
| 29 | Osady ściekowe, OdpadyO): kod 19 08 05 | Pozostałość po prażeniu / straty przy prażeniu suchej masy (LOI) Range (1,0 – 99,0) % Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN 15935:2022-01 | |
| 30 | Osady ściekowe, OdpadyO): kod 19 08 05 | pH – in H2O Range 4,0 – 10,0 Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 31 | Osady ściekowe, OdpadyO): kod 19 08 05 | Sampling for chemical and physical testing Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.4, 6.3.5, 6.3.8, 6.3.10 | ||
Reference standards (29)
PN-82/C-04576/08
PN-EN 12880:2004
PN-EN 15935:2022-01
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 15705:2005
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.4, 6.3.5, 6.3.8, 6.3.10
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
Procedura badawcza PB-01 wyd. V z dn. 02.01.2020 r.
Procedura badawcza PB-03 wyd. III z dn. 02.01.2020 r.
Procedura badawcza PB-04 wyd. IV z dn. 02.01.2020 r.
na podstawie testu HACH LCW 032 i LCW 532