🇵🇱 CHORZOWSKO-ŚWIĘTOCHŁOWICKIE PRZEDSIĘBIORSTWO PL

PCA AB 1173 • Chorzów, Poland • 58 methods

Water & wastewaterMicrobiology

CHORZOWSKO-ŚWIĘTOCHŁOWICKIE PRZEDSIĘBIORSTWO is a laboratory accredited by PCA under number AB 1173 (Chorzów, Poland). Its accreditation scope covers 58 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Wastewater, Swimming pool water, Water intended for human consumption, Water intended for human consumption, Water. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 1173
  • Methods in scope: 58
  • Types of test objects: 8
  • Techniques used: 14
  • City: Chorzów, Poland
Accreditation number
AB 1173
Accreditation body
PCA
Address
WODOCIĄGÓW I KANALIZACJI Sp. z o.o., ul. Składowa 1, 41-500 Chorzów, LABORATORIUM, ul. Kręta 9
City
Chorzów, Poland

What this laboratory tests (8)

Analytical techniques used (14)

Accreditation scope — test methods (58)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Woda do spożycia przez ludzi, Woda, Ścieki Electrical conductivity
Range (10 – 10000) μS/cm
Conductometric method PN-EN 27888:1999
2 Woda do spożycia przez ludzi, Woda, Ścieki Chloride concentration
Range (5,00 - 1000) mg/l
Titrimetric method PN-ISO 9297:1994
3 Woda do spożycia przez ludzi, Woda, Ścieki Nitrate nitrogen concentration
Range (0,045 – 50) mg/l Nitrate concentration Range (0,20 – 220) mg/l
Spectrophotometric method PN-82/C-04576.08
4 Woda do spożycia przez ludzi, Woda, Ścieki Nitrite nitrogen concentration
Range (0,008 – 20) mg/l Nitrite concentration Range (0,025 – 65,7) mg/l
Spectrophotometric method PN-EN 26777:1999
5 Woda do spożycia przez ludzi, Woda, Ścieki Sulfate concentration
Range (10,0 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
6 Woda do spożycia przez ludzi, Woda, Ścieki Element concentration
Ag (0,0050 – 10,0) mg/l Al (0,010 – 10) mg/l As (0,0010 – 10) mg/l B (0,100 – 10) mg/l Ba (0,100 –10,0) mg/l Be (0,100 – 10) mg/l Ca (1,0 – 1000) mg/l Cd (0,0010 – 50) mg/l Co (0,010 –10,0) mg/l Cr (0,0050 –10,0) mg/l Cu (0,010 –10,0) mg/l Fe (0,010 –10,0) mg/l K (1,0 – 1000) mg/l Mg (1,0 – 1000) mg/l Mn (0,0050 – 10) mg/l Mo (0,050 –10,0) mg/l Na (1,00 – 1000) mg/l Ni (0,0020 –10,0) mg/l Pb (0,010 – 10) mg/l Sb (0,0010 – 10) mg/l Se (0,005 – 10) mg/l Sn (0,100 –10,0) mg/l Ti (0,050 –10,0) mg/l V (0,020 –10,0) mg/l Zn (0,010 –10,0) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
7 Woda do spożycia przez ludzi, Woda, Ścieki Element concentration
Hg (0,0010 – 1,0) mg/l Tl (0,010 – 10,0) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PB/33 ed. 1 z dnia 08.10.2010 r.
8 Woda do spożycia przez ludzi, Woda, Ścieki Dissolved oxygen concentration
Range (0,5 – 15) mg/l O2
Regulated area: badania/pomiary wykonywane poza siedzibą Laboratorium
Electrochemical method PN-EN ISO 5814:2013-04
9 Water intended for human consumption, Water Turbidity
Range (0,10 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
10 Water intended for human consumption, Water Free chlorine concentration
Range (0,05 – 2,0) mg/l
Regulated area: badania/pomiary wykonywane poza siedzibą Laboratorium
Colorimetric method PB/19 ed. 3 z dnia 27.10.2016 r. | na podstawie testu HACH nr 8021
11 Water intended for human consumption, Water Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D
12 Water intended for human consumption, Water Total iron concentration
Range (0,010 – 50) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
13 Water intended for human consumption, Water Manganese concentration
Range (0,020 – 1) mg/l
Spectrophotometric method PB/13 ed. 3 z dnia 14.02.2025 r.
14 Water intended for human consumption, Water Total calcium and magnesium content (Total hardness)
Range (5 – 1000) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
15 Water intended for human consumption, Water Ammonium nitrogen concentration
Range (0,050 – 40) mg/l Ammonia concentration Range (0,060 – 51,5) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
16 Water intended for human consumption, Water Permanganate index
Range (0,5 – 10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
17 Water intended for human consumption, Water pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
18 Swimming pool water pH
Range 4,0 – 10,0
Regulated area: badania/pomiary wykonywane poza siedzibą Laboratorium
Potentiometric method PN-EN ISO 10523:2012
19 Swimming pool water Potencjał utleniająco-redukujący (redox) wzgl. elektrody Ag/AgCl 3,5 mol/l KCl
Range (400 – 1000) mV
Regulated area: badania/pomiary wykonywane poza siedzibą Laboratorium
Potentiometric method PB/44 ed. 1 z dnia 16.11.2016 r.
20 Swimming pool water Total chlorine concentration
Range (0,05 – 2,0) mg/l
Regulated area: badania/pomiary wykonywane poza siedzibą Laboratorium
Colorimetric method PB/19 ed. 3 z dnia 27.10.2016 r. | na podstawie testu HACH nr 8167
21 Swimming pool water Free chlorine concentration
Range (0,05 – 2,0) mg/l
Regulated area: badania/pomiary wykonywane poza siedzibą Laboratorium
Colorimetric method PB/19 ed. 3 z dnia 27.10.2016 r. | na podstawie testu HACH nr 8021
22 Swimming pool water Combined chlorine concentration (calculated) PB/19 ed. 3 z dnia 27.10.2016 r.
23 Swimming pool water Permanganate index
Range (0,5 – 10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
24 Wastewater Chemical oxygen demand
COD Range (5,0 – 50000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
25 Wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
26 Wastewater Biochemical oxygen demand
BOD5 Range (1 – 4000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
27 Wastewater Ammonium nitrogen concentration
Range (2,0 – 1000) mg/l
Titrimetric method PN-ISO 5664:2002
28 Wastewater Ammonium nitrogen concentration
Range (0,050 – 80) mg/l Ammonia concentration Range (0,060 – 103) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
29 Wastewater Kjeldahl nitrogen concentration
Range (2,0 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
30 Wastewater Total nitrogen concentration (calculated) PB/29 ed. 2 z dnia 01.07.2009 r.
31 Wastewater Total suspended solids (TSS)
Range (5,0 – 5000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
32 Wastewater Stężenie ortofosforanów (jako P)
Range (0,041 – 35) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 (pkt. 4)
33 Wastewater Total phosphorus concentration
Range (0,041 – 35) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 (pkt. 8)
34 Wastewater Total phosphorus concentration
Range (0,050 – 100) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
35 Wastewater Phenol index
Range (0,007 – 0,5) mg/l
Spectrophotometric method PN-ISO 6439:1994 Metoda B
36 Wastewater Substances extractable with petroleum ether
Range (5,0 – 1000) mg/l
Gravimetric method PN-86/C-04573.01
37 Wastewater pH
Range 4,0 – 10,0
Regulated area: badania/pomiary wykonywane poza siedzibą Laboratorium
Potentiometric method PN-EN ISO 10523:2012
38 Sewage sludge Element concentration
Ca (1,00 – 100000) mg/kg Ca (0,00010 – 10,00) % Cd (1,00 – 200) mg/kg Cr (5,0 – 2000) mg/kg Cu (1,00 – 2000) mg/kg Mg (1,00 – 20000) mg/kg Mg (0,00010 – 2,00) % Ni (10,0 – 2000) mg/kg Pb (5,0 – 2000) mg/kg Hg (1,00 – 200) mg/kg Zn (2,0 – 2000) mg/kg P (10,0 – 100000) mg/kg P (0,0010 – 10,00) %
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07
39 Sewage sludge Dry matter / water content
Range (5,0 – 95) %
Gravimetric method PN-EN 12880:2004
40 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
41 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
42 Water (including swimming pool water) Sampling for microbiological testing PN-EN ISO 19458:2007 | PB/36 ed. 3 z dnia 22.01.2018 r.
43 Swimming pool water Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 | PB/36 ed. 3 z dnia 22.01.2018 r.
44 Wastewater Sampling for chemical and physical testing Automatic method; Manual method PN-ISO 5667-10:2021-11
45 Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
46 Water intended for human consumption Most probable number of Escherichia coli MPN method (Colilert-18 Test) PN-EN ISO 9308-2:2014-06
47 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
48 Water intended for human consumption Most probable number of coliform bacteria MPN method (Colilert-18 Test) PN-EN ISO 9308-2:2014-06
49 Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
50 Water intended for human consumption Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 36°C Plate method (pour plate) PN-EN ISO 6222:2004
51 Water intended for human consumption Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 22°C Plate method (pour plate) PN-EN ISO 6222:2004
52 Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
53 Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10
54 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
55 Swimming pool water Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 36°C Plate method (pour plate) PN-EN ISO 6222:2004
56 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
57 Swimming pool water Legionella sp. count, Matrix A, Procedure 5 (BCYE medium), Procedure 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08
58 Domestic hot water Liczba Legionella sp., Matryca B, Procedura 7 (pożywka GVPC) Membrane filtration method PN-EN ISO 11731:2017-08

Reference standards (45)

PB/13 ed. 3 z dnia 14.02.2025 r.
PB/19 ed. 3 z dnia 27.10.2016 r.
PB/29 ed. 2 z dnia 01.07.2009 r.
PB/33 ed. 1 z dnia 08.10.2010 r.
PB/36 ed. 3 z dnia 22.01.2018 r.
PB/44 ed. 1 z dnia 16.11.2016 r.
PN-82/C-04576.08
PN-86/C-04573.01
PN-EN 12880:2004
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 11885:2009
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 22036:2024-07
PN-EN ISO 54321:2021-07
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 (pkt. 4)
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 (pkt. 8)
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 6439:1994 Metoda B
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
na podstawie testu HACH nr 8021
na podstawie testu HACH nr 8167