🇵🇱 MIEJSKIE WODOCIĄGI I KANALIZACJA SP. Z O.O. PL
Water & wastewaterMicrobiology
MIEJSKIE WODOCIĄGI I KANALIZACJA SP. Z O.O. is a laboratory accredited by PCA under number AB 1156 (Kołobrzeg, Poland). Its accreditation scope covers 36 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Wastewater, Swimming pool water, Water, wastewater.
At a glance
- Accreditation number: PCA AB 1156
- Methods in scope: 36
- Types of test objects: 8
- City: Kołobrzeg, Poland
- Accreditation number
- AB 1156
- Accreditation body
- PCA
- Address
- ul. Artyleryjska 3, 78-100 Kołobrzeg, DZIAŁ LABORATORIUM, Obroty 1a, Bogucino
- City
- Kołobrzeg, Poland
What this laboratory tests (8)
- Water, water intended for human consumption — 17 methods
- Wastewater — 5 methods
- Swimming pool water — 4 methods
- Water, wastewater — 3 methods
- Water, water intended for human consumption, wastewater — 3 methods
- Seawater — 2 methods
- Water intended for human consumption — 1 method
- Water intended for human consumption, swimming pool water — 1 method
Accreditation scope — test methods (36)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 2 | Water, water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3 | ||
| 3 | Water, water intended for human consumption | Chloride concentration Range: (5 – 400) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 4 | Water, water intended for human consumption | Manganese concentration Range: (0,02 – 1,00) mg/l Spectrophotometric method | Pb-06/W,CH wydanie 2 z dnia 30.03.2009 r. | ||
| 5 | Water, water intended for human consumption | Nitrate concentration Range: (0,44 – 50,0) mg/l Spectrophotometric method | PN-82/C-04576/08 | ||
| 6 | Water, water intended for human consumption | Nitrite concentration Range: (0,005 – 0,063) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 7 | Water, water intended for human consumption | Electrical conductivity Range: (100 – 2500) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 8 | Water, water intended for human consumption | Turbidity Range: (0,10 – 20) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 9 | Water, water intended for human consumption | Colour Range: (3 – 40) mg/l Spectrophotometric method | PN-EN ISO 7887:2012+Ap1:2015-06 metoda C | ||
| 10 | Water, water intended for human consumption | Ammonium ion concentration Range: (0,25 – 1,00) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 11 | Water, water intended for human consumption | Total calcium and magnesium content (total hardness) Range: (5 – 600) mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 12 | Water, water intended for human consumption | Calcium concentration Range: (2 – 100) mg/l Titrimetric method | PN-ISO 6058:1999 | ||
| 13 | Water, water intended for human consumption | Magnesium concentration (calculated) | PN-C-04554-4:1999 Załącznik A | ||
| 14 | Water, water intended for human consumption | Total viable count at 22 °C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 15 | Water, water intended for human consumption | Total viable count at 36 °C Plate method (pour plate) | |||
| 16 | Water, water intended for human consumption | Intestinal enterococci count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 17 | Water, water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 18 | Water, water intended for human consumption | Escherichia coli count Membrane filtration method | |||
| 19 | Water intended for human consumption, swimming pool water | Free, total chlorine concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method Combined chlorine concentration (calculated) | Pb-13/W,Ś wydanie 1 z dnia 05.11.2018 r. na podstawie testu Macherey- Nagel 931 215 | ||
| 20 | Swimming pool water | Sampling for chemical and physical testing | IT-131/W,Ś wydanie 1 z dnia 10.12.2018 r. | ||
| 21 | Swimming pool water | Free, total chlorine concentration Range: (0,1 – 2,0) mg/l Colorimetric method Combined chlorine concentration (calculated) | Pb-12/W,Ś wydanie 1 z dnia 05.11.2018 r. na podstawie testu MERCK 1.14801.0001 | ||
| 22 | Swimming pool water | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 23 | Swimming pool water | Oxidation-reduction (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl Range: (200 – 800) mV Potentiometric method | Pb-11/W,Ś wydanie 2 z dnia 08.08.2025 r. | ||
| 24 | Water, water intended for human consumption, wastewater | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 25 | Water, water intended for human consumption, wastewater | Total iron concentration Range: (0,020 – 10,0) mg/l Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 z wyłączeniem pkt. 7.1.2 | ||
| 26 | Water, water intended for human consumption, wastewater | Sulphate concentration Range: (25 – 120) mg/l Spectrophotometric method | Pb-04/W,Ś,CH wydanie 4 z dnia 30.06.2014 r., na podstawie testu Merck 1.14548.0001 | ||
| 27 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method Temperature Range: (0,0 – 40,0) °C | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 28 | Wastewater | Chloride concentration Range: (5 – 4000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 29 | Wastewater | Total phosphorus concentration Range: (0,23 – 20,00) mg/l Spectrophotometric method | Pb-01/Ś wydanie 4 z dnia 15.09.2019 r., na podstawie testu Merck 1.14543.0001 | ||
| 30 | Wastewater | Total nitrogen concentration Range: (2,5 – 200,0) mg/l Spectrophotometric method | Pb-02/Ś wydanie 5 z dnia 19.05.2023 r., na podstawie testu Merck 1.14537.0001 | ||
| 31 | Wastewater | Biochemical oxygen demand- BOD 5 Range: (2 – 4000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019 | ||
| 32 | Water, wastewater | Chemical oxygen demand - SP-COD Range: (10 – 10000) mg/l O 2 Spectrophotometric method | PN-ISO 15705: 2005 | ||
| 33 | Water, wastewater | Total suspended solids (TSS) Range: (2,0 – 2000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 34 | Water, wastewater | Biochemical oxygen demand - BOD 5 Range: (0,5 – 6) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 35 | Seawater | Sampling for chemical and physical testing Temperature Range: (0,0 – 40,0) °C | PN-ISO 5667-9:2005 PN-77/C-04584 | ||
| 36 | Seawater | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
Reference standards (31)
IT-131/W,Ś wydanie 1 z dnia 10.12.2018 r.
PN-82/C-04576/08
PN-C-04554-4:1999 Załącznik A
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3
PN-EN ISO 5815-1:2019
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015-06 metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705: 2005
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10
PN-ISO 5667-9:2005 PN-77/C-04584
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06 z wyłączeniem pkt. 7.1.2
PN-ISO 7150-1:2002
PN-ISO 9297:1994
Pb-01/Ś wydanie 4 z dnia 15.09.2019 r., na podstawie testu Merck 1.14543.0001
Pb-02/Ś wydanie 5 z dnia 19.05.2023 r., na podstawie testu Merck 1.14537.0001
Pb-04/W,Ś,CH wydanie 4 z dnia 30.06.2014 r., na podstawie testu Merck 1.14548.0001
Pb-06/W,CH wydanie 2 z dnia 30.03.2009 r.
Pb-11/W,Ś wydanie 2 z dnia 08.08.2025 r.
Pb-12/W,Ś wydanie 1 z dnia 05.11.2018 r. na podstawie testu MERCK 1.14801.0001
Pb-13/W,Ś wydanie 1 z dnia 05.11.2018 r. na podstawie testu Macherey- Nagel 931 215