🇵🇱 MIEJSKIE WODOCIĄGI I KANALIZACJA SP. Z O.O. PL

PCA AB 1156 • Kołobrzeg, Poland • 36 methods

Water & wastewaterMicrobiology

MIEJSKIE WODOCIĄGI I KANALIZACJA SP. Z O.O. is a laboratory accredited by PCA under number AB 1156 (Kołobrzeg, Poland). Its accreditation scope covers 36 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Wastewater, Swimming pool water, Water, wastewater.

At a glance

  • Accreditation number: PCA AB 1156
  • Methods in scope: 36
  • Types of test objects: 8
  • City: Kołobrzeg, Poland
Accreditation number
AB 1156
Accreditation body
PCA
Address
ul. Artyleryjska 3, 78-100 Kołobrzeg, DZIAŁ LABORATORIUM, Obroty 1a, Bogucino
City
Kołobrzeg, Poland

What this laboratory tests (8)

Accreditation scope — test methods (36)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
2 Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3
3 Water, water intended for human consumption Chloride concentration Range: (5 – 400) mg/l Titrimetric method PN-ISO 9297:1994
4 Water, water intended for human consumption Manganese concentration Range: (0,02 – 1,00) mg/l Spectrophotometric method Pb-06/W,CH wydanie 2 z dnia 30.03.2009 r.
5 Water, water intended for human consumption Nitrate concentration Range: (0,44 – 50,0) mg/l Spectrophotometric method PN-82/C-04576/08
6 Water, water intended for human consumption Nitrite concentration Range: (0,005 – 0,063) mg/l Spectrophotometric method PN-EN 26777:1999
7 Water, water intended for human consumption Electrical conductivity Range: (100 – 2500) µS/cm Conductometric method PN-EN 27888:1999
8 Water, water intended for human consumption Turbidity Range: (0,10 – 20) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
9 Water, water intended for human consumption Colour Range: (3 – 40) mg/l Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 metoda C
10 Water, water intended for human consumption Ammonium ion concentration Range: (0,25 – 1,00) mg/l Spectrophotometric method PN-ISO 7150-1:2002
11 Water, water intended for human consumption Total calcium and magnesium content (total hardness) Range: (5 – 600) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
12 Water, water intended for human consumption Calcium concentration Range: (2 – 100) mg/l Titrimetric method PN-ISO 6058:1999
13 Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 Załącznik A
14 Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
15 Water, water intended for human consumption Total viable count at 36 °C Plate method (pour plate)
16 Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
17 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
18 Water, water intended for human consumption Escherichia coli count Membrane filtration method
19 Water intended for human consumption, swimming pool water Free, total chlorine concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method Combined chlorine concentration (calculated) Pb-13/W,Ś wydanie 1 z dnia 05.11.2018 r. na podstawie testu Macherey- Nagel 931 215
20 Swimming pool water Sampling for chemical and physical testing IT-131/W,Ś wydanie 1 z dnia 10.12.2018 r.
21 Swimming pool water Free, total chlorine concentration Range: (0,1 – 2,0) mg/l Colorimetric method Combined chlorine concentration (calculated) Pb-12/W,Ś wydanie 1 z dnia 05.11.2018 r. na podstawie testu MERCK 1.14801.0001
22 Swimming pool water pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
23 Swimming pool water Oxidation-reduction (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl Range: (200 – 800) mV Potentiometric method Pb-11/W,Ś wydanie 2 z dnia 08.08.2025 r.
24 Water, water intended for human consumption, wastewater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
25 Water, water intended for human consumption, wastewater Total iron concentration Range: (0,020 – 10,0) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06 z wyłączeniem pkt. 7.1.2
26 Water, water intended for human consumption, wastewater Sulphate concentration Range: (25 – 120) mg/l Spectrophotometric method Pb-04/W,Ś,CH wydanie 4 z dnia 30.06.2014 r., na podstawie testu Merck 1.14548.0001
27 Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature Range: (0,0 – 40,0) °C PN-ISO 5667-10:2021-11 PN-77/C-04584
28 Wastewater Chloride concentration Range: (5 – 4000) mg/l Titrimetric method PN-ISO 9297:1994
29 Wastewater Total phosphorus concentration Range: (0,23 – 20,00) mg/l Spectrophotometric method Pb-01/Ś wydanie 4 z dnia 15.09.2019 r., na podstawie testu Merck 1.14543.0001
30 Wastewater Total nitrogen concentration Range: (2,5 – 200,0) mg/l Spectrophotometric method Pb-02/Ś wydanie 5 z dnia 19.05.2023 r., na podstawie testu Merck 1.14537.0001
31 Wastewater Biochemical oxygen demand- BOD 5 Range: (2 – 4000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019
32 Water, wastewater Chemical oxygen demand - SP-COD Range: (10 – 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705: 2005
33 Water, wastewater Total suspended solids (TSS) Range: (2,0 – 2000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
34 Water, wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
35 Seawater Sampling for chemical and physical testing Temperature Range: (0,0 – 40,0) °C PN-ISO 5667-9:2005 PN-77/C-04584
36 Seawater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012

Reference standards (31)

IT-131/W,Ś wydanie 1 z dnia 10.12.2018 r.
PN-82/C-04576/08
PN-C-04554-4:1999 Załącznik A
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3
PN-EN ISO 5815-1:2019
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015-06 metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705: 2005
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10
PN-ISO 5667-9:2005 PN-77/C-04584
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06 z wyłączeniem pkt. 7.1.2
PN-ISO 7150-1:2002
PN-ISO 9297:1994
Pb-01/Ś wydanie 4 z dnia 15.09.2019 r., na podstawie testu Merck 1.14543.0001
Pb-02/Ś wydanie 5 z dnia 19.05.2023 r., na podstawie testu Merck 1.14537.0001
Pb-04/W,Ś,CH wydanie 4 z dnia 30.06.2014 r., na podstawie testu Merck 1.14548.0001
Pb-06/W,CH wydanie 2 z dnia 30.03.2009 r.
Pb-11/W,Ś wydanie 2 z dnia 08.08.2025 r.
Pb-12/W,Ś wydanie 1 z dnia 05.11.2018 r. na podstawie testu MERCK 1.14801.0001
Pb-13/W,Ś wydanie 1 z dnia 05.11.2018 r. na podstawie testu Macherey- Nagel 931 215