🇵🇱 MESKO S.A. PL

PCA AB 1155 • Skarżysko-Kamienna, Poland • 11 methods

EnvironmentMaterials & polymers

MESKO S.A. is a laboratory accredited by PCA under number AB 1155 (Skarżysko-Kamienna, Poland). Its accreditation scope covers 11 test methods in the following areas: Environment, Materials & polymers. Test objects include: Workplace environment − air, Workplace environment – emergency lighting, Workplace environment – indoor electric lighting, Workplace environment − noise.

At a glance

  • Accreditation number: PCA AB 1155
  • Methods in scope: 11
  • Types of test objects: 4
  • City: Skarżysko-Kamienna, Poland
Accreditation number
AB 1155
Accreditation body
PCA
Address
ul. Legionów 122, 26-111 Skarżysko-Kamienna, LABORATORIUM BADAŃ ŚRODOWISKA PRACY, I OCHRONY ŚRODOWISKA, ul. Ekonomii 8, 26-111 Skarżysko-Kamienna
City
Skarżysko-Kamienna, Poland

What this laboratory tests (4)

Accreditation scope — test methods (11)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment − noise A-weighted equivalent sound level A-weighted maximum sound level Range: (24 − 159) dB C-weighted peak sound level Range: (69 − 162) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 - p. 10 i strategię 3 - p. 11
2 Workplace environment − noise Noise exposure level referred to: - an 8-hour daily working time (calculated)
3 Workplace environment − air Sampling for occupational exposure assessment to: − dust agents − inhalable fraction − respirable fraction − organic substances, including − inhalable fraction − inorganic substances, including − respirable fraction – thoracic fraction − metals and their compounds, including − inhalable fraction − respirable fraction - asbestos - respirable fibres Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
4 Workplace environment − air Exposure index (calculated)
5 Workplace environment − air Concentration of harmful dust agents – inhalable fraction - Titanium dioxide - Natural graphite - Wood dust - Dusts not classified according to toxicity - Talc - Magnesium calcium carbonate (dolomite) - Carbon black Range: (0,22 – 17,0) mg/m3 Gravimetric method PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
6 Workplace environment − air Concentration of harmful dust agents – respirable fraction - Natural graphite - Talc Range: (0,13 – 17,0) mg/m3 Gravimetric method PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08
7 Workplace environment – indoor electric lighting Illuminance Range (20 – 9500) lx Direct measurement method PN-83/E-04040.03
8 Workplace environment – indoor electric lighting Average illuminance Illuminance uniformity (calculated)
9 Workplace environment – emergency lighting Illuminance Range (0,5 – 200) lx Direct measurement method PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7
10 Workplace environment – emergency lighting Illuminance uniformity (calculated)
11 Workplace environment – emergency lighting Ratio of minimum to maximum illuminance (calculated)

Reference standards (6)

PN-83/E-04040.03
PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 - p. 10 i strategię 3 - p. 11
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08