🇵🇱 Panek Sp. z o.o. PL
EnvironmentConstruction
Panek Sp. z o.o. is a laboratory accredited by PCA under number AB 1153 (Suwałki, Poland). Its accreditation scope covers 27 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment - air, General environment - noise from installations, equipment and indus…, Workplace environment - energy expenditure, Workplace environment - noise.
At a glance
- Accreditation number: PCA AB 1153
- Methods in scope: 27
- Types of test objects: 11
- City: Suwałki, Poland
- Accreditation number
- AB 1153
- Accreditation body
- PCA
- Address
- ul. Wawrzyńca Gałaja 26, 16-400 Suwałki, LABORATORIUM BADAŃ ŚRODOWISKA PRACY Panek, ul. Wawrzyńca Gałaja 26, 16-400 Suwałki
- City
- Suwałki, Poland
What this laboratory tests (11)
- Workplace environment - air — 8 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- Workplace environment - energy expenditure — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment – cold microclimate — 2 methods
- Workplace environment – hand-arm vibration — 2 methods
- Workplace environment – hot microclimate — 2 methods
- Workplace environment – indoor electric lighting — 2 methods
- Workplace environment – moderate microclimate — 2 methods
- Workplace environment – whole-body vibration — 2 methods
- Workplace environment - indoor emergency lighting — 1 method
Accreditation scope — test methods (27)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment – indoor electric lighting | Illuminance Range: (5 - 10000) lx Direct measurement method | PN-83/E-04040-03 | ||
| 2 | Workplace environment – indoor electric lighting | Illuminance uniformity (calculated) | |||
| 3 | Workplace environment - indoor emergency lighting | Illuminance Range: (0,5 - 200) lx Direct measurement method | PN-EN 1838:2013-11 | ||
| 4 | Workplace environment - noise | A-weighted equivalent sound level A-weighted maximum sound level Range: (40 - 136) dB C-weighted peak sound level Range: (42 - 135) dB Direct measurement method | PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 | ||
| 5 | Workplace environment - noise | Noise exposure level normalised to - an 8-hour working day - an average weekly working time (calculated) | |||
| 6 | Workplace environment – moderate microclimate | Air temperature Range: (10,0 - 30,0) °C Blackened globe temperature Range: (10,0 - 30,0) °C Air humidity Range: (30,0 - 85,0) % Air velocity Range: (0,15 - 5,00) m/s Direct measurement method | PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap1:2014-02 PN-EN ISO 7730:2006/Ap2:2016-04 | ||
| 7 | Workplace environment – moderate microclimate | PMV index PPD index (calculated) | |||
| 8 | Workplace environment – hot microclimate | Air temperature Range: (20,0 - 42,0) °C Natural wet bulb temperature Range: (20,0 - 42,0) °C Blackened globe temperature Range: (20,0 - 42,0) °C Direct measurement method | PN-EN 7243: 2018-01 | ||
| 9 | Workplace environment – hot microclimate | WBGT index WBGTeff index (calculated) | |||
| 10 | Workplace environment – cold microclimate | Air temperature Range: (-5,1 - 10,0) °C Blackened globe temperature Range: (-5,1 - 10,0) °C Air humidity Range: (30,0 - 85,0) % Air velocity Range: (0,15 - 5,00) m/s Direct measurement method | PN-EN ISO 11079:2008 PN-EN ISO 11079:2008/Ap1:2013-10 | ||
| 11 | Workplace environment – cold microclimate | IREQmin index twc index (calculated) | |||
| 12 | Workplace environment – hand-arm vibration | Frequency-weighted effective vibration acceleration Range: (0,2 - 100) ms-2 Direct measurement method | PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004+Ap1:2015-11 | ||
| 13 | Workplace environment – hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz) Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz) (calculated) | |||
| 14 | Workplace environment – whole-body vibration | Frequency-weighted effective vibration acceleration Range: (0,02 - 25) ms-2 Direct measurement method | PN-EN 14253+A1:2011 | ||
| 15 | Workplace environment – whole-body vibration | Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4 awx, 1,4awy, awz) Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) (calculated) | |||
| 16 | Workplace environment - air | Sampling for occupational exposure assessment to: – dust agents - inhalable fraction respirable fraction – organic substances, including inhalable fraction – inorganic substances, including inhalable fraction respirable fraction – metals and their compounds, including inhalable fraction respirable fraction Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | ||
| 17 | Workplace environment - air | Exposure index (calculated) | |||
| 18 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction : - Portland cement - Kaolin - Amorphous and synthetic silica - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Talc - Coal (hard, brown) - Silicon carbide, non-fibrous Range: (0,19 - 20,00) mg/m3 Gravimetric method | PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08 | ||
| 19 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction: - Portland cement - Amorphous and synthetic silica - Crystalline silica – quartz, cristobalite - Organic dusts of animal and plant origin except wood and flour dust - Talc - Coal (hard, brown) - Silicon carbide, non-fibrous Range: (0,15 - 7,30) mg/m3 Gravimetric method | PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08 | ||
| 20 | Workplace environment - air | Gas concentration Range: CO (5,0 - 125) mg/m3 NO (0,87 - 12,5) mg/m3 NO2 (0,38 - 19,3) mg/m3 Electrochemical method | PB 04-03 wydanie 3 z dnia 02.01.2018 r. | ||
| 21 | Workplace environment - air | Exposure indices (calculated) | |||
| 22 | Workplace environment - air | Concentration of iron oxides - calculated as Fe – inhalable fraction – respirable fraction Range (0,07 - 34,72) mg/m3 Spectrophotometric method | PB 06-02 wydanie 2 z dnia 01.10.2015 r. | ||
| 23 | Workplace environment - air | Concentration of manganese and its inorganic compounds - calculated as Mn - inhalable fraction Range (0,02 - 2,08) mg/m3 - respirable fraction Range (0,02 - 2,08) mg/m3 Spectrophotometric method | |||
| 24 | Workplace environment - energy expenditure | Air flow Range: (9,6 - 59,6) dm3/min Direct measurement method | PB 02-05 wydanie 5 z dnia 02.01.2018 r. | ||
| 25 | Workplace environment - energy expenditure | Energy expenditure (calculated) | |||
| 26 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound level Range: (24 - 115) dB Direct measurement method | nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r. | eniem punktu F | ||
| 27 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | |||
Reference standards (17)
PB 02-05 wydanie 5 z dnia 02.01.2018 r.
PB 04-03 wydanie 3 z dnia 02.01.2018 r.
PB 06-02 wydanie 2 z dnia 01.10.2015 r.
PN-83/E-04040-03
PN-EN 14253+A1:2011
PN-EN 1838:2013-11
PN-EN 7243: 2018-01
PN-EN ISO 11079:2008 PN-EN ISO 11079:2008/Ap1:2013-10
PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004+Ap1:2015-11
PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap1:2014-02 PN-EN ISO 7730:2006/Ap2:2016-04
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r.
eniem punktu F
nr 7