🇵🇱 ZAKŁAD PROJEKTOWO-USŁUGOWY HI-EKO S.C. PL

PCA AB 1118 • Opole, Poland • 24 methods

EnvironmentConstruction

ZAKŁAD PROJEKTOWO-USŁUGOWY HI-EKO S.C. is a laboratory accredited by PCA under number AB 1118 (Opole, Poland). Its accreditation scope covers 24 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment − air, General environment − noise from installations, equipment and indus…, General environment − noise from roads, railway lines, tram lines, Workplace environment – cold microclimate.

At a glance

  • Accreditation number: PCA AB 1118
  • Methods in scope: 24
  • Types of test objects: 10
  • City: Opole, Poland
Accreditation number
AB 1118
Accreditation body
PCA
Address
HALINA I ZBIGNIEW JUSZCZAK, LABORATORIUM BADAŃ I POMIARÓW, ul. Wschodnia 25, 45-449 Opole
City
Opole, Poland

What this laboratory tests (10)

Accreditation scope — test methods (24)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment − air Sampling for occupational exposure assessment to: - dust agents – inhalable fraction – respirable fraction - organic substances, including - inhalable fraction - metals and their compounds, including - inhalable fraction - respirable fraction Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
2 Workplace environment − air Sampling for occupational exposure assessment to: - inorganic substances, including – inhalable fraction – respirable fraction Stationary method Personal dosimetry method
3 Workplace environment − air Exposure index (calculated)
4 Workplace environment − air Concentration of harmful dust agents - inhalable fraction: - Petroleum asphalt - Apatites and phosphorites - Portland cement - Titanium dioxide - Natural graphite - Synthetic graphite - Kaolin - Amorphous and synthetic silica - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Carbon black - Talc - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Silicon carbide, non-fibrous Range: (0,13 – 17,00) mg/m3 Gravimetric method PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
5 Workplace environment − air Concentration of harmful dust agents- respirable fraction: - Apatites and phosphorites - Portland cement - Natural graphite - Amorphous and synthetic silica - Organic dusts of animal and plant origin excluding wood dust and flour dust - Diesel engine exhaust - Talc - Coal (hard coal, lignite) Range: (0,13 – 6,31) mg/m3 Gravimetric method PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08
6 Workplace environment − air Carbon monoxide concentration: Range: (2,34 – 234) mg/m3 (2,00 – 200) ppm Electrochemical method PB-01 wydanie 6 z 18.09.2025 r.
7 Workplace environment − hot microclimate Air temperature Range: (15 – 40) °C Natural wet bulb temperature Range: (15 – 40) °C Black globe temperature Range: (15 – 40) °C Direct measurement method PN-EN ISO 7243:2018-01
8 Workplace environment − hot microclimate WBGT index WBGT eff index (calculated)
9 Workplace environment − moderate microclimate Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 40) °C Air humidity Range: (25 – 75) % Air velocity Range: (0,15 – 1) m/s Direct measurement method PN-EN ISO 7730:2006
10 Workplace environment − moderate microclimate PMV index PPD index (calculated)
11 Workplace environment – cold microclimate Air temperature Range: (-30 – 10) °C Blackened globe temperature Range: (-20 – 15) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,4 – 5) m/s Direct measurement method PN-EN ISO 11079:2008
12 Workplace environment – cold microclimate IREQ min index IREQ neutral index t wc index (calculated)
13 Workplace environment − noise A-weighted equivalent sound level A-weighted maximum sound level Range: (25 – 130) dB C-weighted peak sound level Range: (35 – 136) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 – punkt 11
14 Workplace environment − noise Noise exposure level normalised to: - an 8 – hour working day - an average weekly working time (calculated)
15 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (24 – 130) dB Direct measurement method Nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F
16 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)
17 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level, A-weighted sound exposure level Range: (20 – 130) dB Direct measurement method nr 3 | enie Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz.U. 2011 nr 140 poz. 824 i nr 288 | eniem pkt. H
18 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)
19 Workplace environment − indoor and outdoor electric lighting Illuminance Range: (5 – 5000) lx Direct measurement method PN-83/E-04040.03
20 Workplace environment − indoor and outdoor electric lighting Illuminance uniformity (calculated)
21 Workplace environment – hand-arm vibration Frequency-weighted effective vibration acceleration Range: (0,2 – 500) m/s2 Direct measurement method PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11
22 Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (a , a , a ) hwx hwy hwz Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (a , a , a ) hwx hwy hwz (calculated)
23 Workplace environment – whole-body vibration Frequency-weighted effective vibration acceleration Range: (0,03 – 120) m/s² Direct measurement method PN-EN 14253+A1:2011
24 Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz (calculated)

Reference standards (16)

Nr 7
PB-01 wydanie 6 z 18.09.2025 r.
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 – punkt 11
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F
enie Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz.U. 2011 nr 140 poz. 824 i nr 288
eniem pkt. H
nr 3