🇵🇱 „ZAKŁAD WODOCIĄGÓW I KANALIZACJI – SOCHACZEW” Sp. z o.o. PL

PCA AB 1117 • Sochaczew, Poland • 34 methods

Water & wastewaterMicrobiology

„ZAKŁAD WODOCIĄGÓW I KANALIZACJI – SOCHACZEW” Sp. z o.o. is a laboratory accredited by PCA under number AB 1117 (Sochaczew, Poland). Its accreditation scope covers 34 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Wastewater, Water intended for human consumption Wastewater, Rainwater and snowmelt water.

At a glance

  • Accreditation number: PCA AB 1117
  • Methods in scope: 34
  • Types of test objects: 4
  • City: Sochaczew, Poland
Accreditation number
AB 1117
Accreditation body
PCA
Address
ul. Rozlazłowska 7, 96-500 Sochaczew, LABORATORIUM WODNO-ŚCIEKOWE, al. 600-lecia 69
City
Sochaczew, Poland

What this laboratory tests (4)

Accreditation scope — test methods (34)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
2 Water intended for human consumption Colour Range: (2 – 100) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
3 Water intended for human consumption Turbidity Range: (0,10 – 20) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
4 Water intended for human consumption Electrical conductivity Range: (80 – 13000) µS/cm Conductometric method PN-EN 27888:1999
5 Water intended for human consumption Nitrate concentration Range: (0,30 – 50) mg/l Spectrophotometric method PN-82/C-04576.08
6 Water intended for human consumption Nitrite concentration Range: (0,030 – 2,0) mg/l Spectrophotometric method PN-EN 26777:1999
7 Water intended for human consumption Ammonium ion concentration Range: (0,12 – 1,0) mg/l Spectrophotometric method PN-ISO 7150-1:2002
8 Water intended for human consumption Manganese concentration Range: (0,030 – 1,0) mg/l Spectrophotometric method PB-01 wydanie 6 z dnia 28.02.2019 r. na podstawie testu Merck 114770
9 Water intended for human consumption Free chlorine concentration Range: (0,08 – 1,00) mg/l Spectrophotometric method PB-07 wydanie 1 z dnia 28.12.2009 r. na podstawie metodyki z odczynnikiem DPD
10 Water intended for human consumption Permanganate index Range: (0,6 – 10) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001
11 Water intended for human consumption Aluminium concentration Range: (0,05 – 0,4) mg/l Spectrophotometric method PB-16 wydanie 2 z dnia 31.05.2013 r. na podstawie testu Hach Lange LCK 301
12 Water intended for human consumption Total calcium and magnesium content (total hardness) Range: (18 – 500) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
13 Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
14 Water intended for human consumption Total viable count at 36 °C Plate method (pour plate)
15 Water intended for human consumption Most probable number of intestinal enterococci MPN method PB-19 wydanie 3 z dnia 27.02.2019 r. na podstawie testu Idexx Enterolert-DW
16 Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
17 Water intended for human consumption Most probable number of Escherichia coli MPN method
18 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
19 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
20 Water intended for human consumption Wastewater pH Range: 2,0 – 11,0 Potentiometric method PN-EN ISO 10523:2012
21 Water intended for human consumption Wastewater Chloride concentration Range: (10,0 – 400) mg/l Titrimetric method PN-ISO 9297:1994
22 Water intended for human consumption Wastewater Iron concentration Range: (0,050 – 5,00) mg/l Spectrophotometric method PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06
23 Rainwater and snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
24 Rainwater and snowmelt water Total suspended solids Range: (2,0 – 200) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
25 Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (1,0 – 40,0) °C PN-ISO 5667-10:2021-11 PN-77/C-04584
26 Wastewater Total suspended solids (TSS) Range: (2,0 – 1000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
27 Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 3000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
28 Wastewater Biochemical oxygen demand - BOD 5 Range: (2,0 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
29 Wastewater Chemical oxygen demand - COD-Cr Range: (20,0 – 5000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
30 Wastewater Total phosphorus concentration Range: (0,20 – 25,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010
31 Wastewater Nitrate nitrogen concentration Range: (0,100 – 20,0) mg/l Spectrophotometric method PN-82/C-04576.08
32 Wastewater Nitrite nitrogen concentration Range: (0,0036 – 2,58) mg/l Spectrophotometric method PN-EN 26777:1999
33 Wastewater Kjeldahl nitrogen concentration Range: (1,0 – 250) mg/l Titrimetric method PN-EN 25663:2001
34 Wastewater Total nitrogen (calculated) PB-20 wydanie 1 z dnia 01.02.2019 r.

Reference standards (29)

PB-01 wydanie 6 z dnia 28.02.2019 r. na podstawie testu Merck 114770
PB-07 wydanie 1 z dnia 28.12.2009 r. na podstawie metodyki z odczynnikiem DPD
PB-16 wydanie 2 z dnia 31.05.2013 r. na podstawie testu Hach Lange LCK 301
PB-19 wydanie 3 z dnia 27.02.2019 r. na podstawie testu Idexx Enterolert-DW
PB-20 wydanie 1 z dnia 01.02.2019 r.
PN-82/C-04576.08
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994