🇵🇱 EWA NICGÓRSKA-DZIERKO „EQM” SYSTEM I ŚRODOWISKO PL
EnvironmentMetrology & calibration
EWA NICGÓRSKA-DZIERKO „EQM” SYSTEM I ŚRODOWISKO is a laboratory accredited by PCA under number AB 1115 (Wieliczka, Poland). Its accreditation scope covers 16 test methods in the following areas: Environment, Metrology & calibration. Test objects include: Rooms in residential, collective residence and public utility build…, General environment – noise from installations, equipment and indus…, General environment – noise from roads, railway lines, tram lines, General environment – impulse noise from installations and equipment.
At a glance
- Accreditation number: PCA AB 1115
- Methods in scope: 16
- Types of test objects: 6
- City: Wieliczka, Poland
- Accreditation number
- AB 1115
- Accreditation body
- PCA
- Address
- ul. Tadeusza Kościuszki 36G lok. 16, 32-020 Wieliczka
- City
- Wieliczka, Poland
What this laboratory tests (6)
- Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms — 4 methods
- General environment – noise from installations, equipment and industrial plants — 3 methods
- General environment – noise from roads, railway lines, tram lines — 3 methods
- General environment – impulse noise from installations and equipment — 2 methods
- Machinery and equipment – noise — 2 methods
- Rooms in residential, collective residence and public utility buildings – noise — 2 methods
Accreditation scope — test methods (16)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound level Range: (24 – 137) dB Direct measurement method | nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN ISO 9613-2:2002 | ||
| 2 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | |||
| 3 | General environment – noise from installations, equipment and industrial plants | Calculation method | |||
| 4 | General environment – impulse noise from installations and equipment | A-weighted equivalent sound level Range: (24 – 137) dB Direct measurement method | nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) | ||
| 5 | General environment – impulse noise from installations and equipment | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | |||
| 6 | General environment – noise from roads, railway lines, tram lines | A-weighted equivalent sound level A-weighted sound exposure level Range: (24 – 137) dB Direct measurement method | nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140 | nr 288 | ISO 9613-2:2002 NMPB-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads 2011 | ||
| 7 | General environment – noise from roads, railway lines, tram lines | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | |||
| 8 | General environment – noise from roads, railway lines, tram lines | Calculation method | |||
| 9 | Machinery and equipment – noise | Sound pressure level in 1/3 octave bands Mid-band frequency range: (125 – 8 000) Hz Sound pressure level A-weighted sound pressure level A-weighted single event sound pressure level Range: (24 – 137) dB Direct measurement method | PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09 | ||
| 10 | Machinery and equipment – noise | Sound power level Sound energy level (calculated) | |||
| 11 | Rooms in residential, collective residence and public utility buildings – noise | A-weighted equivalent sound level A-weighted maximum sound level Range: (22 – 119) dB Direct measurement method | PN-87/B-02156 | ||
| 12 | Rooms in residential, collective residence and public utility buildings – noise | A-weighted equivalent sound level for reference time T (calculated) | |||
| 13 | Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms | A-weighted equivalent sound level A-weighted maximum sound level Range: (22 – 119) dB Direct measurement method | PN-EN ISO 10052:2007 PN-EN ISO 10052:2007/A1:2010 | ||
| 14 | Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms | Reference A-weighted equivalent sound level for the work cycle Reference A-weighted maximum sound level for the work cycle (calculated) | |||
| 15 | Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms | A-weighted and C-weighted equivalent sound level A-weighted and C-weighted maximum sound level Range (22 – 119) dB Sound pressure level in 1/1 octave bands with centre frequency range: 31,5 – 8 000 Hz Direct measurement method | PN-EN ISO 16032:2006 | ||
| 16 | Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms | Reverberation time in octave and 1/3-octave bands Engineering method | PN-EN ISO 3382-2:2010 | ||
Reference standards (13)
ISO 9613-2:2002 NMPB-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads 2011
PN-87/B-02156
PN-EN ISO 10052:2007 PN-EN ISO 10052:2007/A1:2010
PN-EN ISO 16032:2006
PN-EN ISO 3382-2:2010
PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN ISO 9613-2:2002
enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140
nr 288
nr 3
nr 7
nr 8