🇵🇱 EWA NICGÓRSKA-DZIERKO „EQM” SYSTEM I ŚRODOWISKO PL

PCA AB 1115 • Wieliczka, Poland • 16 methods

EnvironmentMetrology & calibration

EWA NICGÓRSKA-DZIERKO „EQM” SYSTEM I ŚRODOWISKO is a laboratory accredited by PCA under number AB 1115 (Wieliczka, Poland). Its accreditation scope covers 16 test methods in the following areas: Environment, Metrology & calibration. Test objects include: Rooms in residential, collective residence and public utility build…, General environment – noise from installations, equipment and indus…, General environment – noise from roads, railway lines, tram lines, General environment – impulse noise from installations and equipment.

At a glance

  • Accreditation number: PCA AB 1115
  • Methods in scope: 16
  • Types of test objects: 6
  • City: Wieliczka, Poland
Accreditation number
AB 1115
Accreditation body
PCA
Address
ul. Tadeusza Kościuszki 36G lok. 16, 32-020 Wieliczka
City
Wieliczka, Poland

What this laboratory tests (6)

Accreditation scope — test methods (16)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (24 – 137) dB Direct measurement method nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN ISO 9613-2:2002
2 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
3 General environment – noise from installations, equipment and industrial plants Calculation method
4 General environment – impulse noise from installations and equipment A-weighted equivalent sound level Range: (24 – 137) dB Direct measurement method nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)
5 General environment – impulse noise from installations and equipment A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
6 General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Range: (24 – 137) dB Direct measurement method nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140 | nr 288 | ISO 9613-2:2002 NMPB-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads 2011
7 General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
8 General environment – noise from roads, railway lines, tram lines Calculation method
9 Machinery and equipment – noise Sound pressure level in 1/3 octave bands Mid-band frequency range: (125 – 8 000) Hz Sound pressure level A-weighted sound pressure level A-weighted single event sound pressure level Range: (24 – 137) dB Direct measurement method PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09
10 Machinery and equipment – noise Sound power level Sound energy level (calculated)
11 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level A-weighted maximum sound level Range: (22 – 119) dB Direct measurement method PN-87/B-02156
12 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated)
13 Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms A-weighted equivalent sound level A-weighted maximum sound level Range: (22 – 119) dB Direct measurement method PN-EN ISO 10052:2007 PN-EN ISO 10052:2007/A1:2010
14 Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms Reference A-weighted equivalent sound level for the work cycle Reference A-weighted maximum sound level for the work cycle (calculated)
15 Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms A-weighted and C-weighted equivalent sound level A-weighted and C-weighted maximum sound level Range (22 – 119) dB Sound pressure level in 1/1 octave bands with centre frequency range: 31,5 – 8 000 Hz Direct measurement method PN-EN ISO 16032:2006
16 Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms Reverberation time in octave and 1/3-octave bands Engineering method PN-EN ISO 3382-2:2010

Reference standards (13)

ISO 9613-2:2002 NMPB-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads 2011
PN-87/B-02156
PN-EN ISO 10052:2007 PN-EN ISO 10052:2007/A1:2010
PN-EN ISO 16032:2006
PN-EN ISO 3382-2:2010
PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN ISO 9613-2:2002
enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140
nr 288
nr 3
nr 7
nr 8