🇵🇱 GRUPA AZOTY ZAKŁADY AZOTOWE „PUŁAWY” S.A. PL
Environment
GRUPA AZOTY ZAKŁADY AZOTOWE „PUŁAWY” S.A. is a laboratory accredited by PCA under number AB 1109 (Puławy, Poland). Its accreditation scope covers 24 test methods in the following areas: Environment. Test objects include: Workplace environment - air, Workplace environment - electric lighting, Workplace environment - energy expenditure, Workplace environment - hot microclimate.
At a glance
- Accreditation number: PCA AB 1109
- Methods in scope: 24
- Types of test objects: 8
- City: Puławy, Poland
- Accreditation number
- AB 1109
- Accreditation body
- PCA
- Address
- LABORATORIUM HIGIENY PRACY, Al. Tysiąclecia Państwa Polskiego 13, 24-110 Puławy
- City
- Puławy, Poland
What this laboratory tests (8)
- Workplace environment - air — 10 methods
- Workplace environment - electric lighting — 2 methods
- Workplace environment - energy expenditure — 2 methods
- Workplace environment - hot microclimate — 2 methods
- Workplace environment - moderate microclimate — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment − hand-transmitted vibration — 2 methods
- Workplace environment − whole-body vibration — 2 methods
Accreditation scope — test methods (24)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - air | Air sampling for occupational exposure assessment to: - dust agents inhalable fraction respirable fraction Personal dosimetry method | PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004 | ||
| 2 | Workplace environment - air | Air sampling for occupational exposure assessment to: - organic substances, including inhalable fraction - inorganic substances, including inhalable fraction respirable fraction Personal dosimetry method Stationary method | |||
| 3 | Workplace environment - air | Exposure index (calculated) | |||
| 4 | Workplace environment - air | Ammonia concentration Range: (1,5 - 45) mg/m3 Spectrophotometric method | PN-71/Z-04041 PB-01 Edycja 7 z dnia 16.04.2020 r. | ||
| 5 | Workplace environment - air | Formaldehyde concentration Range: (0,033 - 1,0) mg/m3 Spectrophotometric method | PN-76/Z-04045/02 PB-09 Edycja 7 z dnia 14.07.2023 r. | ||
| 6 | Workplace environment - air | Gas concentration Range: CO - (2,3 - 150) mg/m3 (2 -129) ppm NO - (0,25 – 12,5) mg/m3 (0,2 – 10) ppm NO - (0,38 – 9) mg/m3 2 (0,2 – 4,7) ppm CO - (734 - 45750) mg/m3 2 Electrochemical method | PB-04 8 z dnia 15.04.2025 r. | ||
| 7 | Workplace environment - air | Benzene concentration Range: (0,11 - 11,53) mg/m3 Gas chromatography with mass spectrometry detection (GC-MS) | PN-Z-04016-10:2005 PB-08 Edycja 6 z dnia 16.04.2020 r. | ||
| 8 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction: - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Calcium sulphate (VI) (gypsum) Range: (0,15 – 20) mg/m3 Gravimetric method | PN-Z-04507:2022-05+Ap1:2022-08 | ||
| 9 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction: - Organic dusts of animal and plant origin except wood and flour dust - Coal (hard, brown) Range: (0,18 - 20) mg/m3 Gravimetric method | PN-Z-04508:2022-05+Ap1:2022-08 | ||
| 10 | Workplace environment - air | Crystalline silica (quartz, cristobalite) concentration/content - respirable fraction Range: (0,010 - 0,5) mg/m3 Fourier transform infrared spectrometry method (FT-IR) | Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130. | ||
| 11 | Workplace environment − hand-transmitted vibration | Frequency-weighted r.m.s. vibration acceleration Range: (0,211 - 100) m/s2 Direct measurement method | PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004+A1:2015-11 | ||
| 12 | Workplace environment − hand-transmitted vibration | Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (a , a , a ) hwx hwy hwz Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (a , a , hwx hwy a ) (calculated) hwz | |||
| 13 | Workplace environment − whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range: (0,0178 - 25) m/s2 Direct measurement method | PN-EN 14253 +A1:2011 | ||
| 14 | Workplace environment − whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz (calculated) | |||
| 15 | Workplace environment - noise | A-weighted equivalent sound level A-weighted maximum sound level Range: (35 - 136) dB C-weighted peak sound level Range: (50 - 139) dB Direct measurement method | PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i 11 | ||
| 16 | Workplace environment - noise | Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated) | |||
| 17 | Workplace environment - energy expenditure | Air temperature Range: (5 - 35) °C Air flow Range: (10 - 60) dm3/min Direct measurement method | PB-03 edycja 6 z dnia 29.05.2024 r. | ||
| 18 | Workplace environment - energy expenditure | Energy expenditure (calculated) | |||
| 19 | Workplace environment - hot microclimate | Air temperature Range: (15 - 60) °C Natural wet bulb temperature Range: (15 - 60) °C Blackened globe temperature Range: (15 - 60) °C Direct measurement method | PN-EN ISO 7243:2018-01 | ||
| 20 | Workplace environment - hot microclimate | WBGT index WBGT eff index (calculated) | |||
| 21 | Workplace environment - moderate microclimate | Air temperature Range: (10 - 40) °C Blackened globe temperature Range: (10 - 40) °C Air humidity Range: (25 - 75) % Air velocity Range: (0,15 - 5,0) m/s Direct measurement method | PN-EN ISO 7730:2006+Ap2:2016-04 | ||
| 22 | Workplace environment - moderate microclimate | PMV index PPD index (calculated) | |||
| 23 | Workplace environment - electric lighting | Illuminance Range: (0,5 – 9000) lx Direct measurement method | PB-05 edycja 5 z dnia 17.03.2022 r. | ||
| 24 | Workplace environment - electric lighting | Illuminance uniformity (calculated) | |||
Reference standards (15)
PB-03 edycja 6 z dnia 29.05.2024 r.
PB-04 8 z dnia 15.04.2025 r.
PB-05 edycja 5 z dnia 17.03.2022 r.
PN-71/Z-04041 PB-01 Edycja 7 z dnia 16.04.2020 r.
PN-76/Z-04045/02 PB-09 Edycja 7 z dnia 14.07.2023 r.
PN-EN 14253 +A1:2011
PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004+A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006+Ap2:2016-04
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i 11
PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004
PN-Z-04016-10:2005 PB-08 Edycja 6 z dnia 16.04.2020 r.
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05+Ap1:2022-08
Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130.